• Title/Summary/Keyword: 기포 효과

Search Result 177, Processing Time 0.029 seconds

600MW(e) CANDU PHTS Flow Instability and Interconnect Effect

  • Won Jae Lee;Jin Soo Kim;Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.290-301
    • /
    • 1985
  • 600MW(e) CANDU Primary Heat Transport System (PHTS) is composed of the two “figure-of-eight” loops and is designed to operate with the 4% Reactor Outlet Header (ROH) quality at its rated power. This existence of the two compressible regions and the positive flow-qualitly-void feedbacks are the sources of the PHTS flow instability. To ensure the PHTS stability, ROH-ROH interconnect pipes are installed as passive systems. This paper describes the investigation of the PHTS flow instability at its design full power condition. Also studied are the interconnect effect and the inherent system damping effect on the system stability. The time domain stability analyses are accessed by using the ATHER/MOD-I code which is the improved version of the KAERI developed ATHER code. Under the most adverse system modelling, the “figure-of-eight” symmetric loop shows divergent flow oscillations. Under with the interconnect, the PHTS stability is remarkably enhanced so that the system becomes stable. However, even under the conservative pressurizer modelling, the PHTS shows the more convergent flow oscillations. With the interconnect and the pressurizer modelling, its stability is highly credited. Conclusively, the inherent system damping by pressurizer itself can credit the PHTS stability without the interconnect.

  • PDF

Reynolds Number Effects on the Near-Wake of an Oscillating Naca 4412 Airfoil, Part 1 : Mean Velocity Field (진동하는 NACA 4412 에어포일 근접후류에서의 레이놀즈수 효과 1: 평균속도장)

  • Jang,Jo-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.15-25
    • /
    • 2003
  • An experimental. study is carried out to investigate the near-wake characteristics of an airfoil oscillating in pitch. An NACA 4412 airfoil is sinusoidally pitched about the quarter chord point between the angle of attack -6$^{\circ}$ and +6$^{\circ}$. A hot-wire anemometer is used to measure the phase-averaged mean velocities in the near-wake region of an oscillating airfoil. The freestream velocities of present work are 3.4, 12.4, 26.2 m/s, and the corresponding Reynolds numbers are 5.3${\times}10^4$, 1.9${\times}10^5$, 4.l${\times}10^5$, and the reduced frequency is 0.1. Streamwise velocity profiles are presented to show the Reynolds number effects on the near-wake region behind an airfoil oscillating in pitch. All the cases in these measurements show that the velocity defects by the change of the Reynolds number are very large at the lowest Reynolds number $R_N$=5.3${\times}10^4$: and are small at the other Reynolds numbers ($R_N$=1.9${\times}10^5$ and 4.l${\times}10^5$) in the near-wake region. A significant difference of phase-averaged mean velocity between 5.3${\times}10^4$, and 1.9${\times}10^5$ is observed. The present study shows that a critical value of Reynolds number in the near-wake of an oscillating airfoil exists in the range between 5.3${\times}10^4$, and 1.9${\times}10^5$.

Effects of Egg White and Ion Exchange Resin Pretreatment on Separation of Egg White Lysozyme (난백 및 이온교환수지의 전처리 조건이 난백 Lysozyme의 추출에 미치는 영향)

  • 유익종;이성기;김경환;민병용
    • Korean Journal of Poultry Science
    • /
    • v.16 no.3
    • /
    • pp.157-167
    • /
    • 1989
  • Pretreatment of egg white and ion exchange resins was attempted to separate lysozyme from egg white efficiently. Apparent viscosity of egg white could be decreased to 3cp by homogenization for 30 minutes at 2, 000rpm and ultrasonication for 45 minutes. The result of testing adsorption capacity of lysozyme was as follows; CM-Sephadex C-25 >Duolite C464>Amberlite C-50>Dowex MSC-1>Amberlite IRC-50>Amberlite IRC-84. Although CM-Sephadex C-25 showed highest adsorption capacity of lysozyme, egg white could not eluted easily. Duolite Cf64 was selected based on relatively high lysozyme adsorption and good egg white eluting property for separation of egg white lysozyme. Na$^{+}$ form of Duolite C-464 was most effective on adsorption of Iysozyme. To separate lysozyme from egg white efficiently rinse buffer and eluting solution were selected 0.1M sodium phosphate buffer at pH 6.5 and 10% ammonium sulfate respectively. After separating lysozyme from egg white, foaming power of egg white was decreased to 85.3%. Color of egg white gel was not changed while hardness of egg white gel was decreased by 30% after separating lysozyme. However, elasticity of egg white gel was increased by 13% in lysozyme-separated egg white.

  • PDF

Assessing greenhouse gas footprint and emission pathways in Daecheong Reservoir (대청댐 저수지의 온실가스 발자국 및 배출 경로 평가)

  • Min, Kyeong Seo;Chung, Se Woong;Kim, Sung Jin;Kim, Dong Kyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.785-799
    • /
    • 2022
  • The aim of this study was to characterize the emission pathways and the footprint of greenhouse gases (GHG) in Daecheong Reservoir using the G-res Tool, and to evaluate the GHG emission intensity (EI) compared to other energy sources. In addition, the change in GHG emissions was assessed in response to the total phosphorus (TP) concentration. The GHG flux in post-impoundment was found to be 262 gCO2eq/m2/yr, of which CO2 and CH4 were 45.7% and 54.2%, respectively. Diffusion of CO2 contributed the most, followed by diffusion, degassing, and bubbling of CH4. The net GHG flux increased to 510 gCO2eq/m2/yr because the forest (as CO2 sink) was lost after dam construction. The EI of Daecheong Reservoir was 86.8 gCO2eq/kWh, which is 3.7 times higher than the global EI of hydroelectric power, due to its low power density. However, it was remarkable to highlight the value to be 9.5 times less than that of coal, a fossil fuel. We also found that a decrease in TP concentration in the reservoir leads to a decrease in GHG emissions. The results can be used to improve understanding of the GHG emission characteristics and to reduce uncertainty of the national GHG inventory of dam reservoirs.

Ventilation Effect of the Greenhouse with Folding Panel Type Windows (패널굴절방식 환기창 온실의 환기효과)

  • Kim, Jin-Young;Lee, Si-Young;Kim, Hyun-Hwan;Chun, Hee;Yun, In-Hak
    • Journal of Bio-Environment Control
    • /
    • v.11 no.1
    • /
    • pp.5-11
    • /
    • 2002
  • In this study, new development of natural ventilation window was accomplished to control environment of greenhouse with no use of farced ventilation during hot season. The ventilation effect of developed ventilation window was investigated in experimental greenhouse which was designed using side wall panel and folding type panel fur natural ventilation. Folding panel type ventilation window was designed to open upper part of the side wall and top of the roof using two hinges which are located bottom of the side wall and the roof panel to grab one side of each panels and guide the other side along with the guidance rail. Developed ventilation window has top ventilation part with maximum moving distance X=ι (1-cos$\theta$)=848.5 mm and side ventilation part with maximum moving distance Y=ι/2 $\times$sin$\theta$=1,184.4 mm at 45$^{\circ}$ of theoretical opening angle. It took 4.5 minutes to open roof vent fully and temperature at 1.2 and 0.8 m height decreased after 1 minute from starting opening and became equilibrium state maintaining 3-4$^{\circ}C$ difference after 2 minutes from complete opening. Air exchange rate was 15.2~39.3 h$^{-1}$ which was more than 10~15 h$^{-1}$ of continuous type and Venlo type greenhouse. The descent effect of temperature by ventilation windows was two times higher than Venlo type greenhouse.

A Study on the Permeability Reduction Methods of the Riverbed Ground during Urban Railway Tunnel construction (도시철도터널공사 시 하저통과구간의 지반투수저하 공법에 대한 연구)

  • Kim, Joon-Jeong;Cho, Kook-Hwan;Lee, Jun-Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.551-557
    • /
    • 2007
  • This paper describes a study on the permeability reduction of the riverbed ground during urban railway tunnel construction. The research is mainly concentrated on the study of the grouting or injection methods among permeability reduction methods which can be adapted in the riverbed ground. Firstly, the various grouting methods are theoretically reviewed and compared based on the previous research papers and case study results. It is also evaluated the grouting methods in view of a safe construction of the river crossing railway tunnel. Baced on the literature review and previous construction data, the design technology of grouting methods considering the long term hydro-geological behaviour in the riverbed, is suggested. Two injection methods namely, Natural Durable Stabilizer(N.D.S) and Space-Multi Injaction Grouting(S.M.I) methods, are introduced as new approach methods which can be adopted to modify the riverbed ground. In order to evaluate the ground that grouted and modified by the N.D.S and S.M.I method, the pilot test programmes including the field and laboratory permeability tests, are carried out in the river crossing tunnel construction sites. The results obtained from pilot test programme, are also reviewed. In conclusion, the grouting efficiency of the S.M.I method using the non-alcalimeter silica sol is better than that of NDS method using cement. In addition, it hopes that the research results are contributed to develop the grouting design technology.

  • PDF

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Development of integrated microbubble and microfilter system for liquid fertilizer production by removing total coliform and improving reduction of suspended solid in livestock manure (가축분뇨 내 대장균 제거와 부유물질 저감 효율 향상을 통한 추비 생산용 미세기포 부상분리와 마이크로 필터 연계 시스템 개발)

  • Jang, Jae Kyung;Lee, Donggwan;Paek, Yee;Lee, Taeseok;Lim, Ryu Gap;Kim, Taeyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.139-147
    • /
    • 2021
  • Livestock manure is used as an organic fertilizer to replace chemical fertilizers after sufficient fermentation in an aerobic bioreactor. On the other hand, liquid manure disposal problems occur repeatedly because soil spraying is restricted during the summer when the crops are growing. To use liquid fertilizer (LF) as an additional nutrient source for crops, it is necessary to reduce the amount of suspended solids (SS) in the liquid fertilizer and secure stability problems against pathogenic microorganisms. This study examined the effects of the simultaneous SS removal and E.coli sterilization in the LF using the microbubble (MB) generator (FeMgO catalyst insertion). The remaining SS were further removed using the integrated microbubble and microfilter system. During the floating process in the MB device, the SS were removed by 57.9%, and the coliform group was not detected (16,200→0 MPN/100 mL). By optimizing the HRT of the integrated system, the removal efficiency of the SS was improved by 92.9% under the 0.1h of HRT condition. After checking the properties of the treated LF, 64.5%, 70.1%, 54.9%, and 51.5% of the TCOD, SCOD, PO4-P, and TN, respectively, were removed. The treated effluent from such an integrated system has a lower SS content than that of the existing LF and does not contain coliforms; therefore, it can be used directly as an additional fertilizer.

The Long-term Follow-up Study of Therapeutic Effects of 8 French Catheter for Spontaneous Pneumothorax (자연 기흉의 치료에서 8 French 도관삽입의 치료 효과에 대한 장기적 관찰)

  • Shin, Jong-Wook;Lee, Byoung-Hoon;An, Chang-Hyeok;Choi, Jae-Sun;Yoo, Jee-Hoon;Lim, Seong-Yong;Kang, Yoon-Jung;Koh, Hyung-Ki;Kim, Jae-Yeol;Na, Moon-Jun;Park, In-Won;Sobn, Dong-Suep;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1094-1104
    • /
    • 1997
  • Background : Spontaneous pneumothoraces(SP) are divided into primary spontaneous pneumothoraces (PSP) which develop in healthy individuals without underlying pulmonary disorders and secondary spontaneous pneumothoraces(SSP) which occur in those who have underlying disorders such as tuberculosis or chronic obstructive lung diseases. Yet there is no established standard therapeutic approach to this disorder, i.e., from the spectrum of noninvasive treatment such as clinical observation with or without oxygen therapy, to aggressively invasive thoracoscopic bullectomy or open thoracotomy. Although chest tube thoracostomy has been most widely used, the patients should overcome pain in the initiation of tube insertion or during indwelling it potential infection and subcutaneous emphysema. Thus smaller-caliber tube has been challenged for the treatment of pneumothorax. Previously, we studied the therapeutic efficacy of 8 French catheter for spontaneous pneumothorax. But there has been few data for effectiveness of small-caliber catheterization in comparison with that of chest tube. In this study, we intended to observe the long-term effectiveness of 8 French catheter for the treatment of spontaneous pneumothoraces in comparison with that of chest tube thoracostomy. Method : From January, 1990 to January, 1996, sixty two patients with spontaneous pneumothoraces treated at Chung-Ang University Hospital were reviewed retrospectively. The patients were sub-divided into a group treated with 8 French catheter(n=23) and the other one with chest tube insertion(n=39). The clinical data were reviewed(age, sex, underlying pulmonary disorders, past history of pneumothorax, size of pneumothorax, follow-up period). And therapeutic effect of two groups was compared by treatment duration(duration of indwelling catheter or tube), treatment-associated complications and recurrence rate. Results : The follow-up period(median) of 8 French catheter group and chest tube group was 28 and 22 months, which had no statistical significance. Ther was no statistically significant difference of clinical characteristics between two groups with SP, PSP, SSP. The indwelling time of 8 French catheter group was $6.2{\pm}3.8$ days, which was significantly shorter than that of chest tube group in SP, $9.1{\pm}7.5$ days(p=0.047). In comparison of treatment-related complication in PSP, 8 French catheter group as 6.25% of complication showed lower tendency than the other group as 23.8% (p=0.041 ; one-tailed, p=0.053; two-tailed). The recurrence rate in each group of SP was 17.4%, 10.3%, which did not show any statistically significant difference. Conclusion : Treatment with 8 French catheter resulted in shorter indwelling time in sponteous pneumothorax, and lower incidence of treatment-related complication in primary spontaneous pneumothorax. And the recurrence rate in each of treatment group showed no statistically significant difference. So, we can recommend the 8 French small-caliber catheter for the initial therapy for spontaneous pneumothorax for the replacement of conventional chest tube thoracostomy. But further prospective study with more subjects of spontaneous pneumothorax will be needed for the evaluation of effectiveness of 8 French cateter.

  • PDF