• Title/Summary/Keyword: 기준 임플란트

Search Result 57, Processing Time 0.019 seconds

Differences in Intake of Elderly-Friendly Foods according to Oral Health Status of the Elderly (노인의 구강건강상태에 따른 고령친화식품 섭취 차이)

  • Jeon, Ji-Eun;Jung, Eun-Ha;Kim, Soo-Min;Han, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.12
    • /
    • pp.697-704
    • /
    • 2021
  • This study was conducted to provide data for the development of foods suitable for the level of oral health by analyzing the consumption of elderly-friendly foods according to the oral health status of the elderly. Using data from the health questionnaire, oral examination, and nutrition survey of the 7th National Health and Nutrition Examination Survey, the oral health status and nutritional intake status of the elderly by each stage of elderly-friendly foods were analyzed, and a complex sample analysis method was applied. The elderly who mainly consume stage 3 elderly-friendly foods appear to have very poor oral health and nutritional status. Therefore, when developing elderly-friendly foods, it is necessary to develop various foods and provide systematic education considering the oral health status of the elderly and appropriate nutrients.

Comparative analysis of accuracy of how to use the implant torque controllers (사용 방법에 따른 임플란트 토크 조절기의 정확성 비교 분석 연구)

  • Cho, Lee-Ra;Park, Chan-Jin;Huh, Yoon-Hyuk;Lee, Ji-Hye;Kim, Dae-Gon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.300-306
    • /
    • 2013
  • Purpose: This study was to evaluate the accuracy of how to use the Mechanical Torque-Limiting Devices. Materials and methods: Three different implant manufacturers (Dentium, Osstem, Shinhung) were prepared for each two implant torque controllers. Divided into two groups depending on the method used for removal torque was measured. Repeated measures of ANOVA test (${\alpha}=.05$) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque of two groups. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). There was significant difference between two groups. Conclusion: Loosen the handle part of the implant torque controllers spring resilience to recover one group compared to the group that did not, showed a little more closed to the reference value.

An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine (두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.273-285
    • /
    • 2000
  • The aim of this investigation was to evaluate the differences of two canti-leyer springs by using a new simulation system. This was done using a Calorific machine that compared iron uprighting spring and root uprighting spring. The Calorific machine was designed to allow observation of the whole process of tooth moving, and is composed of three parts(a temperature regulating system, electro-thermodynamic teeth, and an artificial alveolar bone component). The experiment of both mechanics were repeated five times and measured two times. The intra-examiner agreement and inlet-examiner agreement were $96.54\%\;and\;95.73\%$ and these data were statistically tested by paired t-test. The obtained results were as follows. 1. Distal and buccal movement of the anchor teeth were observed greater in the root uprighting spring than the crown uprighting spring. 2. Crown uprighting spring showed distal movement of the crown of lower second molar for 3.29mm but root uprighting spring showed only 1.68mm. 3. Crown uprighting spring exhibited forward movement of mesial and distal root of the lower second molar for 3.91mm, 3.60mm but the root uprighting spring showed 6.76mm, 6.26mm.

  • PDF

In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant (Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가)

  • Yeon, Kyoo-Jin;Kim, Hyun-Soo;Lee, Seung-keun;Lee, Tae-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with $45^{\circ}$ intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with $CuSO_4$ solution. And then the artifact size was measured using Susceptibility A rtifact Measurement (SA M) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

Rehabilitation with orthognathic surgery and orthodontic treatment in patient with severe occlusal disharmony: A case report (심한 교합 부조화를 보이는 환자에서 악교정수술 및 교정치료를 동반한 구강회복: 증례 보고)

  • Jung-Jin Lee;Kwang-Yeob Song;Seung-Geun Ahn;Ju-Mi Park;Jae-Min Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.204-214
    • /
    • 2023
  • The occlusal treatment including prosthetic treatment should be considered when the pathologic symptom was observed with the excessive discrepancy between the centric relation occlusion (CRO) and the maximum intercuspal position (MIP). Through careful diagnosis, the malocclusion and interarch relationship can be analyzed, and occlusal adjustment, restorative treatment, orthodontic therapy, or orthognathic surgery can be performed depending on the degree of disharmony. The patient in this case report complained the unstable occlusion and loss of masticatory function that had been occurring for several years. At the time of the visit, the patient showed severe occlusal disharmony, with only the upper right second molar contacting the lower jaw at the maximum intercuspal position. Based on the analysis of the occlusion, it was difficult to solve the problem with just occlusal adjustment or restorative treatment. In addition, the patient had the skeletal class II malocclusion between the upper and lower jaws. Therefore, for resolving the severe skeletal class II malocclusion, pre- and post-orthodontic treatment, bilateral sagittal split ramus osteotomy (BSSRO) was performed. After that, the occlusal adjustment was performed for stable occlusion, and the missing teeth area was restored with dental implants. During the follow-up period, a periodic follow-up visits and additional occlusal adjustments were performed to achieve a stable centric occlusion and harmonious anterior and lateral guidance. As a result, the final prosthodontic treatment was completed, and the patient's masticatory function was restored.

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

Morphological Analysis of the Mental Foramen and Anterior Loop of the Mandibular Canal using Computed Tomography (전산화단층촬영 방사선영상을 이용한 이공과 하악관 전방고리의 형태학적 분석)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 2011
  • The mental foramen and anterior loop of the mandibular canal are important landmarks for mandibular surgical procedures. The purpose of this study was to analyze the shape and position of the mental foramen and anterior loop of the mandibular canal on the computed tomography (CT) images, and apply the results clinically. CT images of 96 patients (33 male, 36 female, age range 17~43 years, mean $24.6{\pm}4.99$ years) were enrolled. The horizontal and vertical position of the mental foramen, as well as the distance from the root apices were measured. The distance of the anterior loop of the mandibular canal to the root apices, and the buccal angle were measured. The mental foramen was found mostly below the second premolar observed in 81 cases (46.0%), between the first and second premolars in 67 cases (38.0%), and between the second premolar and first molar in 19 cases (10.2%). The mean distance between the mental foramen and the lower border of the mandible was $12.20{\pm}1.77$ mm, the mean distance between the mental foramen and root apex was $5.16{\pm}0.98$ mm. The mean distance of the anterior loop of the mandibular canal was $5.80{\pm}2.00$ mm. The buccal angle measured at $47.7{\pm}9.07^{\circ}$. The distance between the root apex and mental foramen measured as $5.16{\pm}0.98$ mm on panoramic radiography, and $6.2{\pm}3.07$ mm on CT. The mean distance between the mental foramen and mandibular canal was $5.39{\pm}1.62$ mm. When performing surgical procedures such as installing dental implants, it is important to minimize surgical trauma, especially the risk of damage to the mental nerve. To optimize the surgical outcome, a careful assessment of the shape and position of the mental foramen and the anterior loop of the mandibular canal must be made. CT images are useful for finding such anatomic structures.