• Title/Summary/Keyword: 기온저감

Search Result 123, Processing Time 0.025 seconds

Analysis of Thermal Environment Modification Effects of Street Trees Depending on Planting Types and Street Directions in Summertime Using ENVI-Met Simulation (ENVI-Met 시뮬레이션을 통한 도로 방향별 가로수 식재 형태에 따른 여름철 열환경 개선 효과 분석)

  • Lim, Hyeonwoo;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.1-22
    • /
    • 2022
  • The modification effects of street trees on outdoor thermal comfort in summertime according to tree planting types and road direction were analyzed using a computer simulation program, ENVI-met. With trees, the air temperature and wind speed decreased, and the relative humidity increased. In the case of mean radiant temperature (Tmrt) and human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI), there was a decrease during the daytime. The greatest change among the meteorological factors by trees happened in Tmrt, and PET and UTCI showed similar patterns with Tmrt·The most effective tree planting type on thermal comfort modification was low tree height, wide tree crown, high leaf area index, and narrow planting interval (LWDN). Tmrt, PET and UTCI showed a large difference depending on shadow patterns of buildings and trees according to solar altitude and azimuth angles, and building locations. When the building shade areas increased, the thermal modification effect by trees decreased. In particular, results on the east and west sidewalks showed a large deviation over time. When applying the LWDN, the northwest, west and southwest sidewalks showed a significant reduction of 8.6-12.3℃ PET and 4.2-4.5℃ UTCI at 10:00, and the northeast, east and southeast sidewalks showed 8.1-11.8℃ PET and 4.4-5.0℃ UTCI at 16:00. On the other hand, when the least effective type (high tree height, narrow tree crown, low leaf area index, and wide planting interval) was applied, the maximum reduction was up to 1.8℃ PET and 0.9℃ UTCI on the eastern sidewalks, and up to 3.0℃ PET and 0.9℃ UTCI on the western ones. In addition, the difference in modification effects on Tmrt, PET and UTCI between the tree planting types was not significant when the tree effects were reduced by the effects of buildings. These results can be used as basic data to make the most appropriate street tree planting model for thermal comfort improvement in urban areas in summer.

Changes in Greenhouse Temperature and Solar Radiation by Fogging and Shading During Hydroponics in Summer Season (여름철 수경재배 시 포그 분무와 차광에 의한 하우스 내부 온도 및 광 환경 변화)

  • Lim, Mi Young;Jeong, Ho Jeong;Roh, Mi Young;Choi, Gyeong Lee;Kim, So Hui;Choi, Su Hyun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.3
    • /
    • pp.230-236
    • /
    • 2021
  • Changes in greenhouse temperature and solar radiation due to fogging and shading were monitored during hydroponics in high temperature in summer season. Experiment 1 consists of four treatments, namely, Control, Shading, Fogging, and Fogging + Shading based on sunny days August. For Experiment 2, two melon cultivars of 'Dalgona' and 'Sopoong gaza' were cultivated in summer of 2020 using Fogging + Shading with the best result for temperature reduction effect from Experiment 1. As a result of Experiment 1, the effect of Fogging + Shading on temperature reduction was apparent where the inside was about 4℃ (as the lowest temperature) lower than the outside. Fogging + Shading showed the inside was 2-4℃ lower than the outside, and Fogging or Shading treatments had little difference, compared to the Control where the internal temperature of greenhouse was 3-4℃ higher than the external. For solar radiation changes between greenhouse inside and outside, the internal change was in a similar pattern between Fogging and Control, and between Shading and Fogging + Shading, respectively. In case of the Fogging treatment (similar with the Control) only the effect of solar radiation reduction as influenced by plastic greenhouse covering materials was examined. The Fogging + Shading had a very similar change in solar radiation to the Shading. Based on these results, Experiment 2 was conducted in summer of 2020 and resulted in a temperature reduction effect of about 3.9℃ according as the inside of air-conditioned greenhouse was kept 32.4℃ when the maximum temperature of the outside reached 36.3℃ in August during the cultivation period. In addition, the quality of melon fruit was good (1.3-1.5 kg of fruit weight, 12.6-13.3 of soluble solids content. In the case of using Fogging + Shading cooling treatment, it can bring about the effect of reducing the temperature during the high temperature in summer, and normal growth of melon and fruit harvesting were possible.

A Study on Air Temperature-reducing Effects by Irrigation Reservoir (도시 내 소규모 관개저수지의 기온 저감효과에 관한 연구 - 수원시 일월저수지를 대상으로 -)

  • Zheng, Hai-Yan;Jin, Wen-Cheng;Lee, Kyoo-Seock;Oh, Sung-Nam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.32-39
    • /
    • 2010
  • The air temperature-reducing effects by irrigation reservoir in urban area was investigated at Ilwol Pond (IWP). Air temperature and humidity data were observed at 10minute interval from September 1th, 2008 to August 31th, 2009. Air temperature of IWP and Sumsung Apartment (SAT) were analyzed to examine air temperature-reducing effects by IWP in terms of diurnal and seasonal variation. As a result, the average air temperature difference between IWP and SAT was $0.6^{\circ}C$ and the nighttime shows more air temperature-reducing effects. The dominant air temperature-reducing effects by IWP occurred at fall night and summer daytime. However, the air temperature-reducing effects by IWP is lower to that by Arboretum (ARB).

Assessment of the ATC Effect for Paddy Field and Forest Using Landsat Images and In-situ Measurement (Landsat영상과 현지조사에 의한 여름철 논과 산림의 기온저감효과 평가)

  • Park, Jong-Hwa;Na, Sang-Il;Kim, Jin-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1943-1947
    • /
    • 2007
  • The objective of this research was to find a direct and indirect method to estimate land surface temperature (LST) efficiently, using Landsat images and in-situ measurement. Agricultural fields including paddy fields have long been known to have multi-functions beneficial to the environment and ecology of the urban surrounding areas. Among these functions, the ambient temperature cooling (ATC) effect are widely acknowledged. However, quantitative and regional assessment of such effect has not had many investigations. Thermal remote sensing has been used over urban areas to assess ATC effect, to perform land cover classifications and as input for models of urban surface atmosphere exchange. Here, we review the use of thermal remote sensing in the study of paddy fields and urban climates, focusing primarily on the ATC effect. Landsat satellite images were used to determine the surface temperatures of different land cover types of a $441km^2$ study area in Cheongju, Korea. The results show that the ATC are a function of paddy area percentage in Landsat pixels. Pixels with higher paddy area percentage have more significant cooling effect.

  • PDF

Assessing the Effects of Climate Change on Irrigation Water Requirement for Corn in Zimbabwe (기후변화가 짐바브웨 옥수수 필요수량에 미치는 영향 평가)

  • Nkomozepi, Temba;Chung, Sang-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • 기후변화는 피할 수 없으며 다음 세기에도 계속될 것이다. 이는 생태계와 토지와 물과 같은 자연자원의 이용에도 영향을 미칠 것이다. 연구 결과에 의하면 아프리카는 낮은 경제수준과 지역적 다양성으로 인하여 기후변화에 가장 취약한 지역 중의 하나이다. 짐바브웨는 한계농지가 황폐화가 되는 등 농업분야가 특히 기후변화에 취약하다. 본 논문에서는 짐바브웨의 주요 옥수수 재배지역에 대하여 기후변화가 옥수수의 필요수량에 미치는 영향을 공간적 및 시간적으로 분석하였다. 미래 기후예측은 HadCM3 전지구 모형 결과에 change factor를 곱하여 추정하였다. 배출가스 시나리오는 A2b 및 B2a를 선정하였고, 시간대는 2020s, 2050s 및 2080s 각각 30년간에 대하여 분석하였다. 기준작물 증발산량은 Penman-Monteith 공식으로, 순관개량은 CROPWAT 모형을 이용하여 구하였다. 순관개량의 공간적인 분석은 GIS를 이용하였다. 분석 결과 대상지역은 강우량이 감소하고 관개의 필요성이 크게 증가할 것으로 나타났다. 2080s의 필요수량은 기준년도 (1961-1990)에 비하여 93 내지 115 % 증가할 것으로 예측되었다. 이 증가는 기온의 증가와 강우량의 감소에 기인한다. 대상 지역에 대한 기후변화 대응 전략 수립과 영향 저감대책에 대한 추가적인 연구가 필요하다고 하겠다.

Calculation of Damage to Whole Crop Corn Yield by Abnormal Climate Using Machine Learning (기계학습모델을 이용한 이상기상에 따른 사일리지용 옥수수 생산량에 미치는 피해 산정)

  • Ji Yung Kim;Jae Seong Choi;Hyun Wook Jo;Moonju Kim;Byong Wan Kim;Kyung Il Sung
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.43 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • This study was conducted to estimate the damage of Whole Crop Corn (WCC; Zea Mays L.) according to abnormal climate using machine learning as the Representative Concentration Pathway (RCP) 4.5 and present the damage through mapping. The collected WCC data was 3,232. The climate data was collected from the Korea Meteorological Administration's meteorological data open portal. The machine learning model used DeepCrossing. The damage was calculated using climate data from the automated synoptic observing system (ASOS, 95 sites) by machine learning. The calculation of damage was the difference between the dry matter yield (DMY)normal and DMYabnormal. The normal climate was set as the 40-year of climate data according to the year of WCC data (1978-2017). The level of abnormal climate by temperature and precipitation was set as RCP 4.5 standard. The DMYnormal ranged from 13,845-19,347 kg/ha. The damage of WCC which was differed depending on the region and level of abnormal climate where abnormal temperature and precipitation occurred. The damage of abnormal temperature in 2050 and 2100 ranged from -263 to 360 and -1,023 to 92 kg/ha, respectively. The damage of abnormal precipitation in 2050 and 2100 was ranged from -17 to 2 and -12 to 2 kg/ha, respectively. The maximum damage was 360 kg/ha that the abnormal temperature in 2050. As the average monthly temperature increases, the DMY of WCC tends to increase. The damage calculated through the RCP 4.5 standard was presented as a mapping using QGIS. Although this study applied the scenario in which greenhouse gas reduction was carried out, additional research needs to be conducted applying an RCP scenario in which greenhouse gas reduction is not performed.

Effects of Pad Cooling Systems in Tunnel-Ventilated Broiler House on Reducing Indoor Temperature and Level of Temperature-Humidity Index during Summer (국내 터널식환기 무창 육계사에서 여름철 쿨링패드 사용에 따른 계사 내부 온도 저감 효과 및 더위지수(THI)에 미치는 영향)

  • Hye Ran Kim;Seol Hwa Park;Jisoo Wi;Seongshin Lee;Sung Dae Lee;Hwan Ku Kang;Chaehwa Ryu
    • Korean Journal of Poultry Science
    • /
    • v.51 no.2
    • /
    • pp.57-63
    • /
    • 2024
  • As global warming worsens, it is feared that higher ambient temperatures and relative humidity might result in a more intense heat stress for livestock animals, especially broilers, which lack sweat glands for thermoregulation and have been selectively bred for rapid growth. Therefore, strategic livestock management is needed to mitigate the adverse effects of heat stress on broilers. In Korea's poultry farming systems, tunnel-ventilated broiler houses and pad cooling systems are commonly installed to lower indoor temperatures during the summer. However, caution is advised with pad cooling systems as they can increase the humidity inside the houses, potentially causing further harm. This study aimed to evaluate the effectiveness of pad cooling systems in tunnel-ventilated broiler house by assessing the reduction in indoor temperature using the Temperature-Humidity Index (THI), which accounts for the impact of relative humidity. Temperature and humidity data were collected during the summer (Jun to Sep) from eight farms with tunnel-ventilated broiler house located in different regions of Korea. The farms were divided into two groups based on the use of pad cooling systems is used, and temperature and humidity data, along with THI values, were analyzed two weeks before the birds were marketed. Meta-analysis results showed that at the hottest time of the day, 14:00, farms with pad cooling systems had significantly lower indoor temperatures compared to the control group, but observed an increase in indoor temperatures by 16:00 (p<0.05). There is no significant difference in relative humidity (p>0.05). The THI values decreased in the treatment group with cooling pads compared to the control group starting from 15:00, suggesting a diminished effect (p<0.05). This study indicates the potential for developing optimal operational guidelines for cooling pads to reduce heat stress in broilers during the summer season.

Estimation of Snow Damage and Proposal of Snow Damage Threshold based on Historical Disaster Data (재난통계를 활용한 대설피해 예측 및 대설 피해 적설심 기준 결정 방안)

  • Oh, YeoungRok;Chung, Gunhui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.325-331
    • /
    • 2017
  • Due to the climate change, natural disaster has been occurred more frequently and the number of snow disasters has been also increased. Therefore, many researches have been conducted to predict the amount of snow damages and to reduce snow damages. In this study, snow damages over last 21 years on the Natural Disaster Report were analyzed. As a result, Chungcheong-do, Jeolla-do, and Gangwon-do have the highest number of snow disasters. The multiple linear regression models were developed using the snow damage data of these three provinces. Daily fresh snow depth, daily maximum, minimum, and average temperatures, and relative humidity were considered as possible inputs for climate factors. Inputs for socio-economic factors were regional area, greenhouse area, farming population, and farming population over 60. Different regression models were developed based on the daily maximum snow depth. As results, the model efficiency considering all damage (including low snow depth) data was very low, however, the model only using the high snow depth (more than 25 cm) has more than 70% of fitness. It is because that, when the snow depth is high, the snow damage is mostly caused by the snow load itself. It is suggested that the 25 cm of snow depth could be used as the snow damage threshold based on this analysis.

Deterioration and Microclimate in the Shelter for the Gaetaesajiseokbulibsang (Standing Triad Buddha Statues in Gaetaesaji Temple Site), Nonsan, Korea (논산 개태사지석불입상의 손상도와 보호각 내부의 미기후 환경)

  • Kim, Ji-Young;Park, Sun-Mi;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.179-196
    • /
    • 2009
  • The Gaetaesajiseokbulibsang (Treasure No. 219) consists of light gray and coarse to medium-grained granodiorite with feldspar phenocrysts in part. Magnetic susceptibility of the rock material was measured as 12.06(${\times}10^{-3}$ SI unit), being different from the granite($0.19{\times}10^{-3}$ SI unit) in the Mt. Cheonho. This indicates the raw material has been supplied from the outside. As a result of deterioration assessment, exfoliation of the Right Buddha, cement and dust of the Main Buddha were estimated as 35.2%, 21.1% and 25.0%. The ultrasonic velocity was measured as 2850.2m/s(Main Buddha), 2648.4m/s(Left Buddha) and 2644.5m/s(Right Buddha). The compressive strength calculated from the velocity showed low in the Right Buddha among three and the all pedestal parts which corresponds to the result of deterioration assessment. The indoor mean temperature and relative humidity of the shelter were $13.7^{\circ}C$ and 79.0%. It is evaluated that the indoor microclimate was stable and the shelter functioned to reduce climatic fluctuation of the outdoor. However, water condensation was occurred on the surface of the pedestal part during spring and summer, and freezing in winter season might also be done. These factors were probable to be a main cause of the surface exfoliation of the Triad Buddha Statues. Therefore, dehumidification and heating system in the shelter should be applied to prevent further deterioration.

  • PDF

Air Temperature Decreasing Effects by Shading and Ventilation at Micro-scale Experiment Plots (소공간 실험구의 차광과 통풍에 의한 기온저감 효과)

  • Kim, Hyun-Cheol;Woo, Ji-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.39-48
    • /
    • 2010
  • The purpose of this study was to analyze air temperature decreasing effects by shading and ventilation at micro-scale experiment plots, especially focused on the Wet Bulb Globe Temperature (WBGT) in outdoor spaces. To monitor the time-serial changes of Dry-bulb Temperature (DT), Globe Temperature (GT) and Relative Humidity (RH) in the wind blocking and shading conditions, Two hexahedral steel frames were established on the open grass field, the dimension of each frame was 1.5m(W)${\times}$1.5m(L)${\times}$1.5m(H). Four vertical side of one frame was covered by transparent polyethylene film to prevent wind passing through (Wind break plot; WP). The top side of the other frame was covered with shading curtain which intercept 95% of solar light and energy (Shading plot; SP). And, Another vertical steel frame without any treatment preventing ventilation and sunlight was set up, which represents natural conditions (Control plot; CP). The major findings were as follows; 1. The average globe temperature (GT) was highest at WP showing $50.94^{\circ}C$ and lowest at SP showing $34.58^{\circ}C$. The GT of natural condition (SP) was $42.31^{\circ}C$ locating the midst between WP and SP. The difference of GT of each plot was about $8-16^{\circ}C$, which means the ventilation and shading has significant effect on decreasing the temperature. 2. WP showed the highest average dry-bulb temperature (DT) of $38.41^{\circ}C$ which apparently differ from SP and CP showing $31.94^{\circ}C$ and $33.15^{\circ}C$ respectively. The DT of SP and CP were nearly the same. 3. The average relative humidity (RH) was lowest at WP showing 15.21%, but SP and CP had similar RH 28.79%, 28.02% respectively. 4. The average of calculated WBGT were the highest at the WP ($27.61^{\circ}C$) and the lowest at the SP ($23.64^{\circ}C$). The CP ($25.49^{\circ}C$) was in the middle of the others. As summery, compared with natural condition (CP), the wind blocking increased about $2.11^{\circ}C$ WBGT, but the shading decreased about $1.84^{\circ}C$ WBGT. So It can be apparently said that the open space with much shading trees, sheltering furnitures and well-delivered wind corridor can reduce useless and even harmful energy for human outdoor activity considerably in outdoor spaces.