• Title/Summary/Keyword: 기술적 비용

Search Result 4,955, Processing Time 0.033 seconds

A Study on Optimal Stage Gauge Network Considering Correlation of Individual Stage Gauge Station (관측소간의 상관관계를 고려한 수위관측망 최적화 연구)

  • Joo, Hong jun;Kim, Duck hwan;Kim, Jung wook;Choi, Chang hyun;Han, Dae gun;Lee, Ji ho;Kim, Hung soo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.404-412
    • /
    • 2016
  • This paper not only aims to establish a plan to acquire the water stage data in a constant and proper manner by using limited manpower and costs, but also establishes the fundamental technology for acquiring the water level observation data or the stage data. For this, this paper focuses on how to acquire the stage data, in a uniform manner, that can represent each basin by developing the technology for establishing the optimal observational network. For that, this paper identifies the current status of the stage gauge stations installed in the ChungJu dam including wetland basin mainly along the national rivers. Then, thus obtained factors are used to develop the representative unit hydrograph. After that, the data are converted into the probability density function. Then, the stations are calculated information transfer amount. As a last step, we establish the optimized stage gauge network by the location of the stage station and space impact that takes into account for the combinations of the number of the stations. In other words, we consider the combination of the stage gauge station with information transfer amount and spatial correlation analysis for estimation.

Analysis of Influential Factors on Wax Deposition for Flow Assurance in Subsea Oil Production System (해저 석유생산시스템에서 유동안정성 확보를 위한 왁스집적 영향요소 분석 연구)

  • Jung, Sun-Young;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.662-669
    • /
    • 2015
  • There has been an increased interest in the mitigation of wax deposition because wax, which usually accumulates in subsea oil-production systems, interrupts stable oil production and significantly increases the cost. To guarantee a required oil flow by mitigating wax deposition, we need to obtain a reliable estimation of the wax deposition. In this research, we perform simulations to understand the major mechanisms that lead to wax deposition, namely molecular diffusion, shear stripping reduction, and aging. While the model variables (shear reduction multiplier, wax porosity, wax thermal conductivity, and molecular diffusion multiplier) can be measured experimentally, they have high uncertainty. We perform an analysis of these variables and the amount of water and gas in the multiphase flow to determine these effects on the behavior of wax deposition. Based on the results obtained during this study for a higher wax porosity and molecular diffusion multiplier, we were able to confirm the presence of thicker wax deposits. As the shear reduction multiplier decreased, the thickness of the wax deposits increased. As the amount of water increased, there was also an increase in the amount of wax deposits until 40% water cut and decreased. As the amount of gas increased, the amount of wax deposits increased because of the loss of the light hydrocarbon component in the liquid phase. The results of this study can be utilized to estimate the wax deposition behavior by comparing the experiment (or field) and simulation data.

The study on the relevance of healthy biorhythm and sub-health (생체리듬과 아건강과의 관련성에 관한 연구)

  • Shin, Jae-Kyoung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1069-1076
    • /
    • 2017
  • Recently, with the development of advanced medical technology and the introduction of most advanced medical equipments, life expectancy increases accordingly. Many people want to live long-lived in health. Therefore, if it is possible to pre-diagnose the sub-health condition and formulate an appropriate treatment plan, we can prevent the disease and reduce social expenditure costs. In this study, we statistically analyzed the data in responding to each questionnaire for healthy biorhythm and sub-health among targeted members of a specific group. The analysis for the effects of healthy biorhythm to male and female showed that there was a significant difference between male and female. In the analysis of the effects of the conditions of healthy biorhythm to the 10 sub-health indicators, the significant effects of good and bad condition has been observed. The results of the decision tree analysis showed that all the respondents with poor hormone and urological sub-health status have bad healthy biorhythms. In summary, in this paper we have shown that it may be possible to improve the sub-health condition and prevent disease in advance if the healthy biorhythm is well controlled.

A Minimum Wavelength Assignment Technique for Wavelength-routed Optical Network-on-Chip (파장 라우팅 광학 네트워크-온-칩에서의 최소 개수 파장 할당 기법)

  • Kim, Youngseok;Lee, Jae Hun;Cui, Di;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.82-90
    • /
    • 2013
  • An Optical Network-on-Chip(ONoC) based on silicon photonics is one of promising technology for next generation exascale computing architectures. Recent active researches on ONoC focus on improving bandwidth further and avoiding path collisions by using wavelength division multiplexing (WDM). However, the number of wavelengths used for the WDM increases linearly as the number of Processing Element (PE) increases in existing ONoCs which adopt centralized routing architecture. The problem will also arises growing cost of optical devices such as light switches and light sources and limits the scalability of ONoC due to the sinal loss caused by interference of distinct light sources. In this paper, we proposes a distributed routing architecture for ONoC which is based on 2D-mesh structure using WDM technique and present a method that minimize the required number of wavelengths exploiting the connectivity of communication. In comparison with existing centralized routing architectures, results show reduction by 56% of the number of wavelengths and 21% of the number of optical switches in $8{\times}8$ networks.

Improvements of the Bidding Process through Order Case Analysis of Specialty Construction (전문건설공사의 발주사례분석을 통한 입찰업무의 개선방안)

  • Kim, Daewon;Shin, Dae-Woong;Shin, Yoonseok;Kim, Gwang-Hee;Yoo, Sangrok;Park, Wonjun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.5
    • /
    • pp.507-514
    • /
    • 2015
  • In recent years, the number of construction projects carried out to repair and reinforce newly built structures and facilities has been on the rise compared to the number of new construction projects, accounting for more than 90 percents of all construction projects carried out by specialty construction companies. However, as some of the ordering parties fill out the required tasks incorrectly, the wrong information on construction bids is announced, and the specialty construction companies that hold a license and technology are unable to get the job at the right time. As such, it is critical to prevent unnecessary time and expense related to the correction of incorrect bid announcements by providing accurate information and definitions, because the tasks of each specialty construction work stipulated in the framework act of construction industry are vague. Therefore, the causes and problems were analyzed based on the correction cases of bid information, and a plan that can address the problem will be proposed. The result of this study can be utilized as fundamental data to achieve an institutional improvement in the bidding service for the specialty construction companies.

Multi-View Video System using Single Encoder and Decoder (단일 엔코더 및 디코더를 이용하는 다시점 비디오 시스템)

  • Kim Hak-Soo;Kim Yoon;Kim Man-Bae
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.116-129
    • /
    • 2006
  • The progress of data transmission technology through the Internet has spread a variety of realistic contents. One of such contents is multi-view video that is acquired from multiple camera sensors. In general, the multi-view video processing requires encoders and decoders as many as the number of cameras, and thus the processing complexity results in difficulties of practical implementation. To solve for this problem, this paper considers a simple multi-view system utilizing a single encoder and a single decoder. In the encoder side, input multi-view YUV sequences are combined on GOP units by a video mixer. Then, the mixed sequence is compressed by a single H.264/AVC encoder. The decoding is composed of a single decoder and a scheduler controling the decoding process. The goal of the scheduler is to assign approximately identical number of decoded frames to each view sequence by estimating the decoder utilization of a Gap and subsequently applying frame skip algorithms. Furthermore, in the frame skip, efficient frame selection algorithms are studied for H.264/AVC baseline and main profiles based upon a cost function that is related to perceived video quality. Our proposed method has been performed on various multi-view test sequences adopted by MPEG 3DAV. Experimental results show that approximately identical decoder utilization is achieved for each view sequence so that each view sequence is fairly displayed. As well, the performance of the proposed method is examined in terms of bit-rate and PSNR using a rate-distortion curve.

Development of Improvement Technology for Achieving Higher Throughput Limit Utilized in the Evaluation of Next Generation Dry Pumps (첨단공정용 드라이펌프 유량 측정 한계 향상기술 개발)

  • Shin, J.H.;Ko, M.K.;Cheung, W.S.;Yun, J.Y.;Lim, J.Y.;Kang, S.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The constant volume flow meter system (the chamber volume in the 22 L class) was developed to estimate the pumping speed of the dry pump used for the industry of the next generation semiconductor and display. In order to insure the validity of the system, The base pressure and the leak rate in the enclosed system were checked, which were the $6{\times}10^{-8}\;mbar$ and $1.5{\times}10^{-6}\;mbar-L/s$, respectively. Furthermore, it is also confirmed that the value of throughput limit in this system was as much as 1 order of magnitude lower than that in a previously developed system in the 875 L class. By using this developed system, the pumping speed of the new small dry pump was measured. It is believed that the new developed system can be alternating the expensive constant pressure flow meter system in the range of $1{\times}10^{-2}\;mbar-L/s{\sim}1{\times}10^{-3}\;mbar-L/s$.

Design of the Submerged Outlet Structure for Reducing Foam at a Power Plant using a Numerical Model Simulating Air Entrainment (공기연행 수치모형을 이용한 발전소 거품저감 수중방류구조 설계)

  • Kim, Ji-Young;Kang, Keum-Seok;Oh, Young-Min;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.452-460
    • /
    • 2008
  • Anti-foaming agents and foam fences have been used to remove the foam at the outfall of power plants, but there are some problems as consumption of maintenance costs and insufficiency of effect. Therefore, development of the methods how to remove the foam by stable coastal structure has been required. In this study, numerical simulation of air entrainment was carried out to design the submerged outlet structure for reducing foam using curtain walls. The air entrainment rate and the discharge of entrained air change according to the shape of weir and curtain wall. Hence, it is necessary to design the optimum section through comparison of each case. The optimum section which has the maximum rate of foam reduction was determined by the simulation results. In addition, it was found that the flow velocity at the submerged outlet is to be smaller than 1 m/s and the submerged depth of curtain wall is to be taller than height of the submerged outlet section.

Micro-Hydropower System with a Semi-Kaplan Turbine for Sewage Treatment Plant Application: Kiheung Respia Case Study (하수처리장 적용을 위한 Semi-카플란 수차가 장착된 마이크로수력발전 시스템: 기흥레스피아 사례)

  • Chae, Kyu-Jung;Kim, Dong-Soo;Cheon, Kyung-Ho;Kim, Won-Kyoung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.363-370
    • /
    • 2013
  • Small scale hydropower is one of most attractive and cost-effective energy technologies for installation within sewage treatment plants. This study was conducted to evaluate the potential of a semi-kaplan micro-hydropower (MHP) system for application to sewage treatment plants with high flow fluctuations and a low head. The semi-kaplan MHP is equipped with an adjustable runner blade, and is without a guide vane, so as to reduce the incidence of mechanical problems. A MHP rating 13.4 kWp with a semi-kaplan turbine has been considered for Kiheung Respia sewage treatment plant, and this installation is estimated to generate 86.8 MWh of electricity annually, which is enough to supply electricity to over 25 households, and equivalent to an annual reduction of 49 ton $CO_2$. The semi-kaplan turbine showed a 90.2% energy conversion efficiency at the design flow rate of 0.35 $m^3/s$ and net head of 4.7 m, and was adaptable to a wide range of flow fluctuations. Through the MHP operation, approximately 2.1% of total electricity demand of Kiheung Respia sewage treatment plant will be achievable. Based on financial analysis, an exploiting MHP is considered economically acceptable with an internal rate of return of 6.1%, net present value of 15,539,000 Korean Won, benefit-cost ratio of 1.08, and payback year of 15.5, respectively, if initial investment cost is 200,000,000 Korean Won.

The present knowledge of farmers on pests and chemical control in grapevine culture (포도농가의 병해충 인식 및 화학적 방제 실태)

  • Cha, Byeong-Jin;Lee, Yun-Sang;Lee, Hyung-Rae
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.1
    • /
    • pp.38-43
    • /
    • 2000
  • As the first step of a research on the establishment of control strategy for grapevine diseases and insects, the current status of pest control and yield losses by them were surveyed from grapevine growers of Korea. For insects, the most difficult to control was a grapevine stem borer and a grapevine clearwing moth was the next. On the other hand, several diseases including anthracnose, downy mildew, powdery mildew, bird's eye rot, leaf blight, were answered by the growers. The occurrence of the pests varied to the cultural practices. Yield loss was more serious in rainfall intercept culture than in plastic film house culture and diseases caused more loss in yield than insects did. However, the grapevine grower's potential for the identification of the kinds of pests was not high enough. When the pest was observed, the growers consulted mainly with local pesticide dealers or neighbouring growers and usually applied the pesticides prescribed by the dealer. More than half of the growers did not use pest control calendar, and most of the growers applied pesticides before any symptom appeared. Also, more than half of the growers applied mixture of at least more than 1 kind of pesticide and nutrients. Insecticides were applied less than 5 times during the season, but it was more than 6 times for fungicides. In the pesticide selection, the growers checked control effect first, regardless of the registration, and the pest control cost per unit area varied very much depending on the growers.

  • PDF