• Title/Summary/Keyword: 기반암 깊이

Search Result 96, Processing Time 0.025 seconds

Near-surface Shear-wave Velocities Derived from Microtremors and Teleseismic Data at the Hwacheon Seismic Station (상시미동 및 원거리 지진 자료로부터 구한 화천 지진관측소의 천부 횡파속도구조)

  • Yun, Won Young;Park, Sun-Cheon;Kim, Ki Young
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.190-195
    • /
    • 2013
  • We estimated near-surface shear-wave velocity (${\nu}_s$) at the Hwacheon seismic station using a geologic log of a well, microtremors recorded during a period of 56 days, and records of three teleseismic events ($M_w{\geq}6.0$). The vs of the 10-m thick soil layer (${\nu}^s_s$= 296 m/s) was determined from horizontal-to-vertical spectral ratios of microtremors recorded at the surface. The average ${\nu}_s$ ($\bar{\nu}_s$= 1,309 m/s) from the surface to the 96-m depth of a borehole sensor, was computed using spectral coherence analyses of data recorded by surface- and borehole-sensors for the three teleseismic events. Using these calculated values of ${\nu}^s_s$ and $\bar{\nu}_s$, the computed bedrock ${\nu}_s$ is 2,150 m/s and the time-averaged ${\nu}_s$ to a 30-m depth is 696 m/s. Accordingly the Hwacheon seismic station is regarded as a relatively good site. The deduced near-surface ${\nu}_s$ can be used for further quantitative evaluation of site amplification and earthquake hazard.

Hydrological Characteristics of Subsurface Stormflow through Soil Matrix and Macropores on forested Hillslopes (산지 사면에서 토양체와 대공극을 통해 발생하는 지표하 호우류의 수문학적 특성)

  • Kim, Kyong-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.777-785
    • /
    • 1997
  • This study was conducted to clarify the hydrological characteristics of subsurface flow through a soil matrix and macropores. The research facility was set up in a 20m-1ong trench excavated down to bedrock at the base of a hillslope in the Panola catchment under USGS Georgia district. 13 macropores were found on the trench face and 6 major macropores were monitored. Matrix and macropore flow were measured during 95.5mm rainfall on March, 6 to 7. 1996. Macropore flow had great influence on formation of peak flow because the delivery time to Peak flow of macropore flow were faster about 10hrs than those of matrix flow. Matrix flow continued to recess for 3 days. On the other hand, macropore flow stopped within 12hrs after the event ceased. This means that matrix flow controls the recession part. The spatial variations of matrix and macropore flow between each trough and collector were very large by a wide range of 8,655.3 $\ell$ to 17.8 $\ell$ . The bed rock surface topography relates closer with the spatial variations of the flow than the surface one.

  • PDF

The Microtremor HVSRs in the SW Korean Peninsula I: Characteristics of the HVSR Peak Frequency and Amplification (한반도 남서부의 상시미동 HVSR 연구 I: 정점주파수와 증폭효과의 특성)

  • Jung, Hee-Ok;Kim, Hyoung-Jun;Jo, Bong-Gon;Park, Nam-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.541-554
    • /
    • 2010
  • Fifteen min-microtremor data sets were collected at 136 sites from a coastal area of Kunsan and 117 sites from an inland area of Jeonju located in SW Korea, and were analyzed for the HVSR (Horizontal to Vertical Spectral Ratio) of the sites. The microtremor spectra of the coastal area have stronger energy in the lower frequency range from 1-6 Hz than those of the coastal area. This result can be attributed to the effect of the waves and tides in the Keum river and the Yellow sea. Twenty four hours of measurement of the microtremor indicated that the microtremor spectrum correlates with the human activities, but the microtremor HVSR peak was observed consistently at the characteristic frequency for the site. The HVSR peaks were grouped into 4 types -"single peak", "double peak", "broad peak" or "no peak"- based on their shapes. More than 90% of the data sets exhibit peak frequencies ($F_0$) which can be easily identified. The distribution of $F_0$ reveals a close relationship with the topography and local geology of the areas, exhibiting high F0s in the hillside areas and low $F_0s$ in the reclaimed land area. While the amplitudes of microtremor HVSR peak frequencies are less than 4 in the downstream of the inland area, those of the recently reclaimed land in the coastal area are extremely high (more than 10). The results of this study indicate that detailed HVSR studies are essential for the earthquake hazard reduction of reclaimed lands.

Geometric Characteristics of Landslides on Natural Terrain according to the Geological Condition (지질조건에 따른 자연사면 산사태의 기하학적 특성)

  • Kim, Kyeong-Su;Song, Young-Suk;Chae, Byung-Gon;Cho, Yong-Chan;Lee, Choon-Oh
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.75-87
    • /
    • 2007
  • The recognitions of geometrical characteristics and occurrence conditions are very important to evaluate the land-slides in natural terrains. In this paper, the geometrical characteristics of landslides are analyzed according to a geo-logical condition in three landslides areas. The three landslides areas are classified to the geological condition. The three landslides areas are Jangheung, Sangju and Pohang. The geology of Jangheung area, Sangju area and Pohang area is gneiss, granite, and the tertiary sedimentary rock, respectively. During a heavy rainfall of $150{\sim}588mm$ in these areas, 1,582 landslides have occurred in 1998. The geometrical characteristics according to the geological condition analyzed from the investigation of these landslides. The frequency of landslide is high exceedingly above 90% of a slope attitude, while the frequency is very low below 70%. The frequency of landslide is high exceedingly between $26^{\circ}$ and $30^{\circ}$ of slope angle, while the frequency is very low below $20^{\circ}$. The size of the landslides is ranged from several tens to several hundreds The length is ranged from 5 m to 300 m, and the width is ranged from 3 m to 50 m. Also, the depth is less than 1 m. Therefore, the landslides in these areas have small width, long length and shallow depth. The type of the landslides is changed from transitional slide at the scarp to debris flow at the low part of slope.

Late Quaternary Stratigraphy of the Tidal Deposits In the Hampyung Bay, southwest coast of Korea (한국 서남해 함평만 조간대 퇴적층의 제4기 후기 층서 연구)

  • Park, Yong-Ahn;Lim, Dhong-Il;Choi, Jin-Yong;Lee, Young-Gil
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.138-150
    • /
    • 1997
  • The late Quaternary stratigraphy of the tidal deposits in the Hampyung Bay, southwestern coast of Korea comprises 1) Unit III (nonmarine fluvial coarse-grained sediments), 2) Unit II (late Pleistocene tidal deposits), and 3) Unit I (late Holocene fine-grained tidal deposits) in ascending order. The basements of the Hampyung Bay is composed of granitic rocks and basic dyke rocks. These three units are of unconformally bounded sedimentary sequences. The sequence boundary between Unit I and Unit II, in particular, seems to be significant suggesting erosional surface and exposed to the air under the cold climate during the LGM. The uppermost stratigraphic sequence (Unit I) is a common tidal deposit formed under the transgression to highstand sea-level during the middle to late Holocene.

  • PDF

Evaluation of Soil-Structure Interaction Responses of LNG Storage Tank Subjected to Vertical Seismic Excitation Depending on Foundation Type (기초형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 수직방향 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.367-374
    • /
    • 2019
  • We investigate the effect of soil-structure interaction (SSI) on the response of LNG storage tanks to vertical seismic excitation depending on the type of foundation. An LNG storage tank with a diameter of 71 m on a clay layer with a thickness of 30 m upon bedrock, was selected as an example. The nonlinear behavior of the soil was considered in an equivalent linear method. Four types of foundation were considered, including shallow, piled raft, and pile foundations (surface and floating types). In addition, the effect of soil compaction within the group pile on the seismic response of the tank was investigated. KIESSI-3D, an analysis package in the frequency domain, was used to study the SSI and the stress in the outer tank was calculated. Based on an analysis of the numerical results, we arrived at three main conclusions: (1) for a shallow foundation, the vertical stress in the outer tank is less than the fixed base response due to the SSI effect; (2) for foundations supported by piles, the vertical stress can be greater than the fixed base stress due to the increase in the vertical impedance due to the piles and the decrease in radiation damping; and (3) soil compaction had a miniscule impact on the seismic response of the outer tank.

Correlation interpretation for surface-geophysical exploration data-Chojeong Area, Chungbuk (지표물리탐사 자료의 상관해석-충북 초정지역)

  • Gwon, Il Ryong;Kim, Ji Su;Kim, Gyeong Ho
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.75-88
    • /
    • 1999
  • A recent major subject of geophysical exploration is research into 3-D subsurface imaging with a composite information from the various geophysical data. In an attempt to interpret Schlumberger sounding data for the study area in 2-D and 3-D view, resistivity imaging was firstly performed and then pseudo-3-D resistivity volume was reconstructed by interpolating several 1-D resistivity plots. Electrical resistivity discontinuities such as fracture zone were successfully clarified in pseudo-3-D resistivity volume. The low resistivity zone mainly associated with fracture zone appears to develop down to granitic basement in the central part of the study area. Seismic velocity near the lineament is estimated to be approximately as small as 3,000 m/s, and weathering-layer for the southeastern part is interpreted to be deeper than for the northwestern part. Geophysical attributes such as electrical resistivity, seismic velocity, radioactivity for the Chojeong Area were analysed by utilizing a GIS software Arc/Info. The major fault boundaries and fracture zones were resolved through image enhancement of composite section (electrical resistivity and seismic refraction data) and were interpreted to develop in the southeastern part of the area, as characterized by low electrical resistivity and low seismic velocity. However, radioactivity attribute was found to be less sensitive to geological discontinuities, compared to resistivity and seismic velocity attributes.

  • PDF

Seismic Soil-Structure Interaction Analyses of LNG Storage Tanks Depending on Foundation Type (기초 형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min;Lee, Changho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.3
    • /
    • pp.155-164
    • /
    • 2019
  • In this study, the soil-structure interaction(SSI) effect on the seismic response of LNG storage tanks was investigated according to the type of foundation. For this purpose, a typical of LNG storage tank with a diameter of 71m, which is constructed on a 30m thick clay layer over bedrock was selected, and nonlinearity of the soil was taken into account by the equivalent linearization method. Four different types of foundations including shallow foundation, piled raft foundation, and pile foundations(surface and floating types) were considered. In addition, the effect of soil compaction in group piles on seismic response of the tank was investigated. The KIESSI-3D, which is a SSI analysis package in the frequency domain, was used for the SSI analysis. Stresses in the outer tank, and base shear and overturning moment in the inner tank were calculated. From the comparisons, the following conclusions could be made: (1) Conventional fixed base seismic responses of outer tank and inner tank can be much larger than those of considering the SSI effect; (2) The influence of SSI on the dynamic response of the inner tank and the outer tank depends on the foundation types; and (3) Change in the seismic response of the structure by soil compaction in the piled raft foundation is about 10% and its effect is not negligible in the seismic design of the structure.

Analysis of the Causes of Clustered Scismicity Registered in Yeoncheon, the Middle Part of the Korean Peninsula through Gravity Field Interpretation and Modeling (중력이상 수치해석을 통한 연천지역 군발지진 원인분석)

  • Sungchan Choi;Sung-Wook Kim;Eun-Kyeong Choi;Younghong Shin;Tae-Kyung Hong
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.633-648
    • /
    • 2022
  • Gravity data were analyzed to identify the cause of clustered seismicity that occurred intensively in Yeoncheon, located in the central part of the Korean Peninsula. Our analysis suggests that the En echelon faults developed in the northwest-southeast direction. In addition, in the eastern part of the Dongducheon Fault, it was interpreted that high-density lower bedrock intermittently lifts close to the surface due to vertical tectonic movement accompanied by a flower structure. The fracture zone of the Dongducheon Fault is estimated that the width is about 200 m, the depth is at least 5 km, and the density is about 15% lower than the adjacent rocks. It is analyzed that the shallow earthquakes that occurred within 5 km depth was concentrated along the low-density En echelon fault fracture zone developed between the high-density rocks intruding close to the surface. Therefore, the earthquakes can be interpreted as the result that the north-south stress caused by the dextral tectonic movement of the Dongducheon Fault activated the En echelon fault in the northwest-southeast direction.

Analysis of Stability and Behavior of Slope with Solar Power Facilities Considering Seepage of Rainfall (태양광 발전시설이 설치된 사면의 강우시 침투를 고려한 안정성 및 거동 분석)

  • Yu, Jeong-Yeon;Lee, Dong-Gun;Song, Ki-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.7
    • /
    • pp.57-67
    • /
    • 2023
  • Slope failures during rainfall have been observed in mountainous areas of South Korea as a result of the presence of solar power facilities. The seepage behavior and pore pressure distribution differ from typical slopes due to the presence of impermeable solar panels, and the load imposed by the solar power structures also affects the slope behavior. This study aims to develop a method for evaluating the stability of slopes with solar power facilities and to analyze vulnerable points by considering the maximum slope displacement. To assess the slope stability and predict behavior while considering rainfall seepage, a combined seepage analysis and finite difference method numerical analysis were employed. For the selected site, various variables were assumed, including parameters related to the Soil Water Characteristic Curve, strength parameters that satisfy the Mohr-Coulomb failure criterion, soil properties, and topographic factors such as slope angle and bedrock depth. The factors with the most significant influence on the factor of safety (FOS) were identified. The presence of solar power facilities was found to affect the seepage distribution and FOS, resulting in a decreasing trend due to rainfall seepage. The maximum displacement points were concentrated near the upper (crest) and lower (toe) sections of the slope.