밀폐형 전시케이스의 기밀성능 평가방법 연구 (Study on the Performance Evaluation of the Air-tightened Exhibition Case in the Museum)

  • 김재용;노광철;오명도
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.184-190
    • /
    • 2002
  • This study was undertaken to judge the quality of air-tightened exhibition cases. Exhibition cases for artifacts display provide a layer of protection between the interior conditions in the exhibition case and the exterior fluctuating conditions of temperature and relative humidity in the museum environment. An infiltration model of the exhibition case was developed through the experimental measurements to calculate the number of air change rate in the exhibition case undergoing in a day, which represents the airtightness of the exhibition case. The results indicate that tighter exhibition cases provide greater protection against the fluctuating conditions of temperature and humidity outside. When the temperature and humi- dity difference between the exhibition case in-and-out is larger, some absorption materials should be applied to control the environmental conditions in the exhibition case.

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

충청지역 단독주택의 기밀성능 실측 연구 (A Study on the Measurement of Airtightness Performance of Detached Houses in Chung-cheong area)

  • 윤종호;박재완;이광성;백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.65-71
    • /
    • 2008
  • The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 $hr^{-1}$ which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

네트워크 바이오 인증 기반 산업기술 유출방지 시스템에 관한 연구 (A Study on Industrial Security Outflow Prevention System Based on Network Biometric Authentication)

  • 이대성
    • 융합보안논문지
    • /
    • 제11권4호
    • /
    • pp.31-36
    • /
    • 2011
  • 첨단기술을 보유하고 있는 기업이나 핵심정보를 처리하는 정보기관은 조직의 기밀이 유출되는 시점에서 막대한 경제적 손실은 물론, 치명적인 피해에 따른 조직의 존립 자체가 흔들리게 된다. 기존의 오프라인으로 유출되던 기밀정보는 최근 유비쿼터스 통신 환경을 기반으로, 다양한 장비를 통해 언제든지 네트워크를 통해 유출이 가능해졌다. 본 논문에서는 네트워크로 전송되는 기밀유출을 차단하기 위해 전송되는 모든 패킷에 대해 실시간으로 패킷을 인증하고 차단하는 통신 프로토콜을 제안한다. 특히, 기밀유출을 시도하는 사용자를 구분하기 위하여 전송되는 패킷마다 사용자 바이오 정보를 투명하게 삽입하는 기법을 제시한다. 또한, 실험을 통해 사용자 바이오 정보를 삽입하고 패킷마다 인증하더라도 효과대비 그 성능이 크게 저하되지 않음을 확인한다.

기밀성과 무결성이 우수한 SHACAL-2 기반 스트림 암호 설계 및 구현 (Design and Implementation of Stream Cipher based on SHACAL-2 Superior in the Confidentiality and Integrity)

  • 김길호;조경연
    • 한국멀티미디어학회논문지
    • /
    • 제16권12호
    • /
    • pp.1427-1438
    • /
    • 2013
  • 5단계 파이프라인으로 구성된 기밀성과 무결성이 우수하고 실시간처리가 가능한 128비트 출력 스트림 암호를 개발했다. 개발한 스트림 암호는 ASR 277비트와 SHACAL-2를 통해 128비트 스트림을 만들고 이를 CFB모드 적용한 후 표백처리 과정을 통하여 최종적인 128비트 암호문을 만드는 스트림 암호 알고리즘이다. 스트림 암호의 하드웨어는 Verilog HDL을 사용하여 Modelsim 6.5d를 활용하여 기능을 검증하였고, 성능은 Quartus II 12.0을 활용하여 분석했고, Worst Case에서 Max Frequency는 33.34MHz(4.27Gbps)의 빠른 성능을 보여주었다. 이는 무선 인터넷과 센서 네트워크 및 DRM 환경의 속도를 충분히 만족함을 보여준다. 기밀성과 무결성이 우수한 스트림 암호 알고리즘 개발에 본 논문은 매우 유용한 아이디어를 제공하고 있다.

건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 - (An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses-)

  • 이수인;김정국;김서훈;김종훈;정학근;장철용
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

다가구 및 다세대 원룸주택의 기밀성능 실측연구 (The Measurement of Airtightness Performance of Multi-Family Housing)

  • 백남춘;한승현;이왕제;윤종호;신우철
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

지중케이블의 절연통 보호대책 및 방식층 보호장치의 특성 (Characteristics of the Surge Protector for Underground Cable)

  • 김석수;조한구;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.72-75
    • /
    • 2001
  • 전력케이블 선로에 가해지는 전압은 상시교류전압이외에 지락 등에 의한 사용주파과전압과 뇌써지와 같은 써지성 과전압이 있다. 써지성 과전압이 케이블 심선에 침입할 경우 종단접속부나 절연접속함의 접속점은 절연통 양단 및 시스와 대지간에 고전압이 발생하여 케이블심선-시스간 시스-대지간의 써지임피던스 비에 따라 과전압이 발생하며, 이와 같이 써지성 과전압이 방식층의 충격내전압치를 초과할 경우 방식층을 보호하기 위한 대책이 필요하며 그 보호장치로 절연통 보호장치를 사용하는 것이 일반적이다. 절연통에 대한 보호대책과, 설계 제작된 절연통 보호장치에 대한 주요시험항목을 실시하여 항목별 그 특성을 검토하고 절연통 보호장치의 지중송전선로에서 사용되는 조건인 열적내량을 검증하는 충격전류시험과 침수에 의한 기밀성능을 검증하는 내수성능시험을 실시함으로써 그 중요성을 인식할 수 있었다.

  • PDF

Internet을 이용한 DLC 시스템의 보안 (Security consideration of DLC on Internet)

  • 이재인;배두현;송오영;박세현
    • 한국정보보호학회:학술대회논문집
    • /
    • 한국정보보호학회 2003년도 동계학술대회
    • /
    • pp.376-385
    • /
    • 2003
  • 본 논문에서는 인터넷을 이용한 DLC 시스템의 보안 방안에 대한 연구와 제안된 시스템의 성능평가 내용을 기술한다. 이 논문에서는 DLC 시스템만이 아닌 다양한 제어 시스템에서의 보안 시스템 구성이 가능한 방법을 제안하였다. DLC 시스템의 보안 요소는 데이터 기밀성과 무결성, 부인 방지, 제어장치와 서버간의 상호인증이다. 데이터 기밀성과 무결성은 SSL을 통해서 해결하고 제어장치와 서버간의 상호인증은 PKI 서명을 통해서 해결하였다. 또한, DLC 시스템과 같은 close system에서 사설 PKI의 사용을 통한 시스템 성능향상에 대해 살펴본다.

  • PDF

한식 창호의 개구 면적에 따른 기밀 및 차음 성능간 상관성 연구 (A Correlation Analysis between the Airtightness and Sound Insulation Performance on the Opening Spaces of Han-style Windows)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.87-95
    • /
    • 2014
  • The purpose of this study is to evaluate the correlation coefficients between the airtightness and sound insulation performance of Han-style windows in New Han-ok. To achieve these goals, field measurements were accomplished in 18 bedrooms of 16 Han-oks in which actual residents were living, and then lab measurements were proceeded in the reverberation lab for evaluating the sound insulation performance. Followings are results. The results of the correlation analysis between the airtightness(Air change per hour at 50 Pa, ACH50) and sound insulation performance(Sound reduction index, Rw) in bedrooms of actual Han-oks, it was found that there were no significant correlation between two evaluating values. On the other hand, it was analyzed that the correlation coefficients of total 24 structures(double casement windows, single casement window, casement and sliding windows, single sliding window, 6 types per each structure) were located on 0.6757 exponentially and 0.4154 lineary in the lab evaluating conditions. But, The results of evaluating 4 structure classificatorily, it was found that there were high correlation coefficients(0.8665~0.9273 at ACH50, 0.8414~0.9346 at Rw). These results were signified that the correlation coefficients were changed according to the each structure and case by case analysis were necessary at the same time.