패시브 디자인을 적용한 주택의 기밀성에 관한 실측 사례 연구 (The measurement study on the airtightness of dwellings based on the passive design)

  • 이태구;윤두영
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.13-20
    • /
    • 2013
  • Today, the world energy consumption in buildings occupies more than 30%. In our country, the energy consumption in buildings also occupies 25% of the entire national energy consumption. With the increasing demand of energy saving in architectural fields, there is a more interest in low-energy construction. For these low-energy housings, our country is planning to apply the energy-saving design standards at the level of passive houses in 2017. However, there is still a limitation in energy saving only with the standards on the performance of envelope in buildings. This means that unless a building is airtight even though it was well-insulated, cooling and heating energy consumption will increase due to the infiltration and leakage. Therefore, this study aims to make a comparative analysis of airtight performance by conducting a blower door test on the housings applied with passive designs, analyze the reasons why most houses fall short of the airtightness standards, and complement the airtightness problems in the inadequate parts of the buildings in order to save building energy.

자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구 (A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation)

  • 전주영;김길태;김선동
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.325-332
    • /
    • 2014
  • 본 연구에서는 창문형 자연환기장치가 설치된 7개 세대의 소형공동주택($33m^2{\sim}51m^2$)을 대상으로 Blower Door를 이용한 현장 기밀성능 및 공기유동 성능을 측정하였다. 창문형 자연환기장치는 외기에 면하는 모든 창호 및 거실분합문에 설치되어 있으며, 수동 개폐형 장치가 설치되어있다. 본 연구에서는 자연환기장치와 창호의 개폐여부에 따라서 6개의 CASE를 설정하여 실측하였다. 측정결과, 자연환기장치와 모든 개구부를 밀폐한 상태의 기밀성능 값(CASE1)은 1.77~3.12ACH로 평균 2.27ACH로 나타났으며, 문헌조사 결과 자연환기장치가 설치되지 않은 일반 공동주택(1.65~4.28ACH)과 유사하게 나타났다. 내외측의 자연환기장치를 모두 열었을 때의 공기유동성능 값(CASE6)은 평균 5.87ACH로 나타나 밀폐조건과 비교하여 평균 3.6ACH가 증가하는 것으로 나타났다. 외측 환기장치와 창호를 밀폐한 조건에서 내측 환기장치만 개방시와 내측창을 개방시의 공기유동성능값의 차이는 평균 0.29ACH로 내측창호 개방시의 기밀성능 값이 높게 나타났다. 반대로 내측 환기장치와 창호를 밀폐한 조건에서 외측 환기장치만 개방시와 외측창 개방시의 차이는 평균 0.30ACH로 외측창호 개방시가 높게 나타났다. 내측창호만의 공기유동성능과 외측창호만의 공기유동성능 측정값의 차이는 0.77ACH로 내측창호가 더 우수하게 나타났다. 향후에는 자연환기장치와 창호 및 새시의 종류에 따른 기밀성능의 추가 측정을 통해 정량적 상관관계 조사가 필요할 것으로 판단된다.

신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구 (Field Measurement of Infiltration in New Apartments using De-pressurization Method)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.27-32
    • /
    • 2013
  • Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.

충청지역 단독주택의 기밀성능 실측 연구 (A Study on the Measurement of Airtightness Performance of Detached Houses in Chung-cheong area)

  • 윤종호;박재완;이광성;백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.65-71
    • /
    • 2008
  • The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 $hr^{-1}$ which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구 (Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

다가구 및 다세대 원룸주택의 기밀성능 실측연구 (The Measurement of Airtightness Performance of Multi-Family Housing)

  • 백남춘;한승현;이왕제;윤종호;신우철
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

도시철도 전동차 소음 특성에 관한 연구 (A Study on the Noise Characteristics of Subway Train)

  • 최용운;구정서;유원희;고효인
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.329-334
    • /
    • 2009
  • 지하철은 지상교통과 비교하여 정확성, 신속성, 안전성, 대량성외에도 배기가스 배출이 없다는 이점 때문에 대도시 교통 문제 해결을 위한 유용한 수송 수단이 되고 있다. 그러나 콘크리트 도상에 의한 터널 구조로 객실내 소음이 사회적으로 문제가 되고 있다. 이에 객실 소음을 분석하기 위하여 임시열차 운행을 통하여 실측 된 결과를 토대로 소음의 경로와 위치별 소음의 특성을 분석하였다. 객실내 소음 저감을 위해서는 차량측면은 저주파 대역을 차량 바닥은 중대역구간의 소음 대비책을 강구 하여야 하며, 차량의 투과 손실 향상 및 차체의 기밀을 유지하는 것이 필요하다.

지하 원유 저장공동에서의 누수량 산정에 대한 연구 (Estimation of Water Leak Rate in the Underground Oil Storage Cavern)

  • 심현진;박태준;정우철;김호영;최영태
    • 터널과지하공간
    • /
    • 제20권4호
    • /
    • pp.233-240
    • /
    • 2010
  • 지하 원유 저장공동에서 두 공동간의 혼유 방지를 위해 설치되는 더블 플러그는 구조물 시공 후 더블 플러그 내부를 물로 채운 후에 충수의 누수 정도를 파악함으로써 플러그 기밀성을 평가한다. 만약 예상 누수량이 과소하게 산정되면 시공비용이 증대되고, 과다하게 산정될 경우에는 운영비용이 증가될 수 있으므로 최적의 예상 누수량을 산정할 필요가 있다. 본 연구에서는 더블 플러그(double plug) 주변의 투수특성을 보다 정확하게 반영할 수 있도록 수리 안정성 해석을 수행하였으며, 수리 안정성 해석 및 기존 사례 분석 과정을 통해 플러그 주변의 누수 가능성이 있는 모든 경로에 대한 예상 누수량을 산정하였다. 또한 누수 경로에 대한 누수량을 실측 하여 예상 누수량 산정 결과의 신뢰성을 확인하였다.

신축공동주택의 기밀성능 실측에 관한 연구 (The Field Measurement of Airtightness in the Apartment Buildings)

  • 박원석;윤재옥
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

개방계 측정시스템을 이용한 토마토 호흡속도의 자동측정

  • 이현동;윤홍선;이원옥;정훈;조광환
    • 한국식품저장유통학회:학술대회논문집
    • /
    • 한국식품저장유통학회 2003년도 춘계총회 및 제22차 학술발표회
    • /
    • pp.141-141
    • /
    • 2003
  • 신선농산물의 호홉속도를 측정하는 방법 중 하나인 개방계(open system) 호흡속도 측정시스템은 소정의 농도로 조정된 혼합기체를 측정대상시료에 흘려 보내며 측정하는 방법이다. 개방계 측정법의 장점은 혼합 기체조성 영역에서 정확한 호흡속도를 얻을 수 있으며 방치시간이 필요 없으므로 반복 측정이 용이한 것 등이다. 그러나 개방계 측정법은 공급되는 혼합기체의 농도와 유속이 일정하여야 하며 연속으로 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측에서 기체시료를 수집하여 매우 미세한 기체농도의 차이를 측정할 수 있어야 하고 기체 시료 수집에 상당한 주의가 요구된다. 이러한 문제를 개선하기 위하여 개방계 호흡속도 측정 시스템을 자동화하였다. 자동화된 호흡속도 측정 시스템은 혼합기체 발생장치, 온도조절이 가능한 기체기밀용 챔버와 G.C로 구성되어 있다. 환경기체조성을 위한 혼합기체발생장치는 $N_2$, $O_2$, $CO_2$ 압축 실린더에서 공급되는 기체를 압력 조절기를 통해서 일차압력을 조정하고 정밀 압력 조절기를 이용하여 0.1~0.2 kg/$\textrm{cm}^2$의 정압을 유지시켰다. 압력이 일정해진 기체는 metering valve를 이용하여 각 기체의 유량을 소정의 비율로 제어할 수 있도록 하였으며 각각의 기체는 gas mixed cell에서 실험 농도의 환경기체조성으로 혼합되어 항온기내의 호흡속도 측정 챔버($25^{\circ}C$)로 공급될 수 있도록 하였다. 호흡속도 측정용 챔버는 개스킷이 장착된 아크릴 재질이며 온도 조절이 가능한 항온기로 구성되어 있다. 호흡속도 측정용 챔버와 G.C간의 기체흐름은 three way solenoid valve에 의하여 제어되며 전원의 on/off에 따라 공급측의 가스와 배기측의 가스가 선택적으로 G.C에 공급될 수 있도록 구성하였다. 측정 대상 챔버의 기체는 제어된 유로를 따라 multi-position valve를 통과하여 G.C에서 분석되도록 하였다. 본 연구에서 개발된 개방계 호흡속도 자동 측정 시스템의 성능 실험에서 혼합기체발생장치에서 조제된 혼합 기체의 농도를 설정치와 비교한 결과 $O_2$$CO_2$의 농도에서 평균오차 0.2%로 정밀한 것으로 나타났으며 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측의 가스 농도를 3회 반복 측정한 결과 재현성에서는 0.1%이하의 편차로 나타났다. 개방계 호흡속도 자동 측정 시스템을 이용하여 환경기체조성하에서 토마토의 호흡속도를 측정하는 실측 실험을 수행한 결과 2$0^{\circ}C$에서 12.7~42.1mg$CO_2$/kg.hr였으며 12$^{\circ}C$에서 2.5~8.2mg$CO_2$/kg.hr로 일반적으로 보고되고 있는 토마토 호흡속도와 일치하는 결과를 나타내었다.

  • PDF