• Title/Summary/Keyword: 기도 수축

Search Result 866, Processing Time 0.028 seconds

Measurement of the Common Carotid Artery by Ultrasound as a Predictor of Atherosclerosis in Obese Adolescents (비만 청소년에서 동맥경화증을 조기에 예측하기 위한 경부 초음파를 이용한 경동맥 측정)

  • Kim, Ye Jin;Shim, Yoon Hee;Yoo, Joung Hyun;Lee, Keun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.745-752
    • /
    • 2005
  • Purpose : Adolescent obesity is known to be associated with complications such as hypertension, coronary artery disease and insulin resistance. We measured the common carotid artery by ultrasound as a predictor of atherosclerosis, and investigated the relationship between carotid artery parameters and serum cytokines in obese adolescents. Methods : Twenty-nine obese adolescents(16-17 years old, obesity index>130 percent) and twentyseven normal controls were included. Obesity index and body mass index were calculated from their height and weight. Skin fold thickness was measured at the triceps, and fat mass and fat distribution by bioelectrical impedence analysis. Blood pressure was measured at resting state and serum lipid, insulin, and homocysteine levels after a 12-hour fasting period. Intimal wall thickness, systolic and diastolic diameters of the common carotid artery were measured by ultrasound, and compliance and distensibility calculated by equation. Results : Systolic and diastolic diameters of the carotid artery significantly correlated with arm circumference, body mass index, fat distribution and fat mass. The higher systolic blood pressure was, the larger systolic and diastolic diameter. The higher diastolic blood pressure was, the larger carotid intimal thickness. Insulin levels had positive correlations with systolic, diastolic diameters and serum homocysteine level with intimal thickness. Conclusion : The carotid artery diameter significantly increased with the degree of obesity and blood pressure. The carotid intimal wall thickness significantly correlated with diastolic blood pressure. Measurement of carotid artery thickness, insulin and homocysteine levels might be useful to predict the development of coronary artery disease.

Effect of Health Behavior and Obesity Indices on Blood Pressure in 20s Man (20대 성인 남성에서 건강행태와 비만지표가 혈압에 미치는 영향)

  • Kim, Chul-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.231-238
    • /
    • 2011
  • This study was conducted to explore the effect of health behavior and obesity indices on blood pressure(BP) in 20s men. This was a retrospective exploratory study and the subjects were 214 men who participated in screening test for clinical trial at a tertiary hospital between October 2006 and April 2011. The proportion of normal SBP and DBP was 28.5% and 50.0%, respectively. BP was significantly higher in individuals who were hypertriglyceridemia and hypercholesterolemia than BP in subjects of opposing categories. DBP was significantly higher in individuals who were 25~29 years and smokers than DBP in subjects of opposing categories. The significant factors of increasing SBP were BMI and TG, and those for DBP were TC, TG, age, and smoking amount. In conclusion, these results demonstrate hypertention prevention program to include decreasing intake of TC and TG, maintaining normal BMI and quitting smoking needs to the young men in 20s.

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT (게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Cheon, Gi-Jeong;Kim, Yu-Kyeong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.487-496
    • /
    • 2000
  • Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

  • PDF

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

Nutritional and Health Status of the Elderly Living in Songnam - I. Anthropometric Measurements and Biochemical Nutritional Status - (성남지역 노인의 영양 및 건강상태 조사 I. 신체 계측 및 생화학적 영양상태)

  • 권종숙;이홍재
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.4
    • /
    • pp.310-320
    • /
    • 2003
  • To study the nutritional and health status of the elderly in Songnam, the anthropometic measurments, fat composition of body(FAT), blood pressure(BP) and blood test for analyzing biochemical indies of the elderly in seongnam were carried out in 338 free-living elderly (161 men, 177 women) aged from 58 to 92. Anthropometric measurements and blood pressure were assessed, and body fat was analyzed by BI(Bioelectrical Impedence) method. Biochemical measurements including blood glucose(BG), GPT, serum total cholesterol(TC) and albumin(AL) were analyzed. Average heights of the subjects were lower than the standards established in the Korean Recommended Dietary Allowances, and average weights were similar to the standards. FAT were significantly higher in women(36.4%) than men(27.7%), and both groups showed higher values than the reference. Mean systolic BP levels of men and women were 153.3mmHg and 153.7mmHg, and diastolic BP levels were 87.5mmHg and 86.0mmHg, respectively, and there were no significant differences between the sex. Mean BG levels of men and women were 115.9mg/㎗ and 123.7mg/㎗, respectively, and there were no significant differences between the sex and among the age groups. Mean GPT levels of men and women were 19.4unit and 18.1unit, respectively, and women older than 75 years showed significanly low levels of GPT compared to other women's age groups. Mean TC levels of men and women were 186.0mg/㎗ and 206.6mg/㎗, respectively, and significantly higher TC levels were shown in women than men. Mean AL levels of men and women were 4.8g/㎗ and 4.8g/㎗, respectively, and men aged 50 ∼ 64 years showed significant high AL levels compared to other age groups of men. It was suggested that nutrition education program was a good way to improve health status of the elderly.

The convergence effect of phenylephrine, isoprenaline and prazosin on vascular contractility (혈관 수축성에 대한 phenylephrine, isoprenaline 및 prazosin의 융합성 조절 효과)

  • Je, Hyun Dong;Min, Young Sil
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2022
  • In the study, we endeavored to investigate the effect of phenylephrine, isoprenaline and prazosin on the tissue-specific vascular contractility and to determine the mechanism involved. There were few reports addressing the question whether thin or thick filament modulation is included in phenylephrine, isoprenaline and prazosin-induced regulation. We hypothesized that isoprenaline and prazosin play a role in tissue-dependent regulation of vascular contractility. Denuded arterial muscles of Sprague-Dawley male rats were suspended in organ baths and isometric tensions were transduced and recorded using isometric transducers and an automatic data acquisition system. Interestingly, sustained continuous contraction of thoracic and abdominal aorta. Furthermore, isoprenaline and prazosin together with phenylephrine inhibited transiently and persistently vasoconstriction of thoracic and abdominal aorta suggesting that additional mechanisms (e.g. decreased receptor density, chemical interaction, postreceptor signaling or distribution of agonists) might be included in the modulation of vascular contractility.

Muscle Eccentric Control in Gait Initiation (보행 시작 시 원심성 근육 수축 조절)

  • Kim, Hyeong-Dong
    • Physical Therapy Korea
    • /
    • v.8 no.4
    • /
    • pp.81-89
    • /
    • 2001
  • There are two independent mechanisms to control the segmental reflex gain in humans during gait. They are presynaptic inhibition and homosynaptic depression. Through the mechanism of the presynaptic inhibition, the muscle spindle afferent feedback can be properly gated during eccentric phase of gait. The modulation of the presynaptic inhibition is reflected in the level of H-reflex at a constant EMG level. During the eccentric muscle activation presynaptic inhibition should increase to account for the lower amplitude level of H-reflex at a constant level of EMG. Homosynaptic depression is another mechanism responsible for regulating the effectiveness of the muscle spindle afferent feedback. Both the presynaptic inhibition and the monosynaptic depression are responsible for modulating reflex gain during gait initiation. Reflex modulation is influenced not only as a passive consequence of the alpha motor neuron excitation level, but also through supraspinal mechanisms. Spastic paretic patients show the impaired soleus H-reflex modulation either during the initial stance phase, or during the swing phase. This abnormal modulatory mechanism can partially and artificially be restored by the application of peripheral stimulus to the sole of the foot, provided that the segmental circuitry remains functional.

  • PDF

The effect of Smart Care ubiquitous health service on hypertension management (고혈압관리에서의 스마트케어 서비스의 효과)

  • Chung, Young-Soon;Moon, Mikyung;Lee, Chang Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1213-1220
    • /
    • 2013
  • The purpose of this study was to identify the effect of the Smart Care ubiquitous healthcare service on hypertension management. Fifty one patients with inadequately controlled blood pressure (Systolic Blood Pressure ${\geq}$ 140 mmHg despite prescribed antihypertensive medication) from 4 local clinics participated in this study. Remote biometric monitoring and healthcare consultation via videophone was provided to the participants during 24 week - Smart Care service. The average number of blood pressure monitoring and the average day of remote consult using Smart Care Service system was 121 and 14.8 per participant. As a result of analyzing change in blood pressure during 24 weeks, there was a significant difference in blood pressure between baseline and 24 weeks. Systolic blood pressures of 86.3% participants were dropped within a normal range at 24 week. Smart Care u-health service could be effective in reducing blood pressure.

Risk Factors in Relation to Blood Pressure in Schoolchildren (국민학교 학동의 혈압에 관련된 요인분석)

  • Lee, Dong-Soo;Lee, Kyeong-Soo;Kang, Pock-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.345-359
    • /
    • 1993
  • This study was conducted to identify the factors related to the blood pressure in school children. The study subjects were 144 boys and 140 girls aged 10 years old, 4th grade student of one elementary school in Taegu City. Blood pressure and 18 variables for 284 school children were measured in May 1992. A weight-for-height index, R$\ddot{o}$hrer index(weight/$height^3$) was calculated for each individual as a measure of obesity. Body fat percent, fat weight, and lean body mass were measured by impedance fat meter(Model SIF-891). Serum total cholesterol, high-density lipoprotein, triglyceride, uric acid, total protein, and electrolyte were measured by automated clinical chemistry analyzer(Hitachi 4020). Low-density lipoprotein and atherogenic index were calculated by the equation. The variables assessed were sex, systolic blood pressure, diastolic blood pressure. R$\ddot{o}$hrer index, body fat percent, body fat weight, lean body mass, total cholesterol, high-density lipoprotein, low-density lipoprotein, uric acid, total protein, serum electrolyte and blood glucose. The mean systolic and diastolic blood pressures for boys were 104.1mmHg and 66.6mmHg and those for girls were 102.9mmHg and 67.5mmHg. Systolic blood pressure of boys was positively correlated with height, weight, R$\ddot{o}$hrer index, fat weight, lean body mass, and triglyceride. Systolic blood pressure of girls was positively correlated with height, weight, lean body mass, and uric acid. Diastolic blood pressure of boys was positively correlated with weight. R$\ddot{o}$hrer index, and lean body mass. Diastolic blood pressure of girls was positively correlated with height, weight, fat weight, and lean body mass and negatively with total serum protein. In multiple regression analysis for the systolic blood pressure, the significant independent variables were R$\ddot{o}$hrer index and serum sodium in boys, and serum uric acid, fat percent, and R$\ddot{o}$hrer index in girls. In multiple regression analysis of the diastolic blood pressure, the significant independent variables were R$\ddot{o}$hrer index in boys and total serum protein in girls. This study indicated that important factors influencing blood pressure in school children were R$\ddot{o}$hrer index, fat percent, serum sodium, uric acid, and total protein. R$\ddot{o}$hrer index was most important among these. It is recommended to enforce the nutritional education for diet control of obesity to prevent hypertention in children and to adopt healthy life-styles that promote good health and prevent development of cardiovascular risk factors.

  • PDF

Effect of Hydroxocobalamin on Contractile Responses to Phenylephrine during Administration of Inhalational Anesthetics in Lipopolysaccharide-Treated Rat Aortae (흡입마취제 투여시 내독소혈증흰쥐 대동맥 수축반응에 미치는 Hydroxocobalamin의 효과)

  • Kim, In-Kyeom;Yang, Eun-Kyoung
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.3
    • /
    • pp.381-388
    • /
    • 1996
  • The hemodynamic changes in septic patients produced by inhalational anesthetics are sufficient to threaten the anesthesiologists. The effect of hydroxocobalamin, a vitamin $B_{12a}$, on contractile responses to phenylephrine during administration of inhalational anesthetics were evaluated in aortic ring preparations obtained from LPS-treated rats. The sepsis was developed by intraperitoneal injection of LPS (1.5 mg/kg for l8h) and confirmed by iNOS expression using RT-PCR. Statistical significances (P<0.05) were analyzed by Student's t-test or paired t-test according to data characteristics. The blood pressure, but not heart rate, was decreased in LPS-treated rats as compared to control rats. The contractile response to phenylephrine were dose-dependently increased from the doses of $10^{-8}\;M$ to that of $10^{-5}$ and were attenuated in LPS-treated rings. Both halothane and enflurane, at the doses of 1 MAC, decreased the contractile responses to phenylephrine while isoflurane did not significantly affect the contractile responses. Hydroxocobalamin ($10^{-5}$ M) significantly potentiated the contractile responses in the LPS-treated aortic ring preparations during administration of each inhalational anesthetic or not. From these results, it is suggested that hydroxocobalamin may improve the hemodynamics of septic patients during inhalational anesthesia. Abbreviations: LPS, lipopolysaccharide; RT-PCR, reverse transcription-polymerase chain reaction; MAC, minimum alveolar concentration; iNOS, inducible nitric oxide synthase; GAPDH, glyceraldehyde 3-phosphate dehydrogenase

  • PDF