Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT

게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성

  • Paeng, Jin-Chul (Department of Nuclear Medicine, Seoul national University College of Medicine) ;
  • Lee, Dong-Soo (Department of Nuclear Medicine, Seoul national University College of Medicine) ;
  • Cheon, Gi-Jeong (Department of Nuclear Medicine, Seoul national University College of Medicine) ;
  • Kim, Yu-Kyeong (Department of Nuclear Medicine, Seoul national University College of Medicine) ;
  • Chung, June-Key (Department of Nuclear Medicine, Seoul national University College of Medicine) ;
  • Lee, Myung-Chul (Department of Nuclear Medicine, Seoul national University College of Medicine)
  • 팽진철 (서울대학교 의과대학 핵의학교실) ;
  • 이동수 (서울대학교 의과대학 핵의학교실) ;
  • 천기정 (서울대학교 의과대학 핵의학교실) ;
  • 김유경 (서울대학교 의과대학 핵의학교실) ;
  • 정준기 (서울대학교 의과대학 핵의학교실) ;
  • 이명철 (서울대학교 의과대학 핵의학교실)
  • Published : 2000.12.30

Abstract

Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

목적: 국소 심근 벽 운동과 수축기 심근두꺼워짐에 대한 자동정량화 소프트웨어의 재현성을 알아보고자 하였다. 대상 및 방법: 31명의 무작위 추출한 관상동맥질 환자에서 부하 게이트 Tc-99m-MIBI SPECT를 시행하는 중에, 게이트 심근 SPECT를 1회 시행한 이후 바로 이어 한번 더 게이트 SPECT를 시행하였다. 얻어진 영상으로부터 AutoQUANT 소프트웨어를 이용하여 분절별, 심근벽별로 심근벽 운동과 수축기 심근두꺼워짐의 자동정량값을 얻어, 1회째 값과 2회째 값 사이의 상관계수를 계산하고 Bland-Altman 도표를 통해 변이의 범위를 보았다. 또 각 값들을 등급화한 수치 간에 kappa 값을 구해보았다. 결과: 재현성 분석에서 1회와 2회 시행간의 상관계수는 각각 0.948, 0.878이었으며, weighted kappa 값은 0.807, 0.708로 아주 좋은 일치도를 보였다. Bland-Altman 분석에서 변이의 2 표준편차 범위는 각각 ${\pm}2.0mm,\;{\pm}20.2%$였다. 각각의 재현성은 분절영역, 성별, 관류의 수준에 따라 차이를 보이지 않았다. 결론: 이 연구에서 우리는, 심근 벽 운동과 수축기 심근두꺼워짐의 자동정량화 소프트웨어가 좋은 재현성을 가지고 있음을 알았으며, 또한 추적 검사나 치료효과 판정시 심근 벽 운동과 수축기 심근두꺼워짐의 변화 판정 기준을 마련하였다.

Keywords