• Title/Summary/Keyword: 기능적전기자극

Search Result 164, Processing Time 0.038 seconds

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

ELECTROPHYSIOLOGICAL CHARACTERISTICS OF GABAERGIC INHIBITION IN THE HIPPOCAMPAL CA1 OF THE RAT IN VIVO (생체내 흰쥐 해마 CA1 세포에서 가바성 억제에 대한 전기생리학 특성)

  • Choi, Byung-Ju;Cho, Jin-Hwa;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.7-14
    • /
    • 2000
  • Inhibitory cells are critically involved in shaping normal hippocampal function and are thought to be important elements in the development of hippocampal pathologies. The present study was carried out in hippocampal CA1 area in vivo to compare with hippocampal slice studies. Intracellular and extracellular recordings with or without bicuculline electrodes were obtained in the intact brain of anesthetized rats, and cells were intracellularty labelled with neurobiotin. Electrical stimulation of fimbria-fornix resulted in an initial short-latency population spike. In the presence of $10{\mu}M$ bicuculline, orthodromic stimulation resulted in bursts of population spikes. The amplitude of population spikes in the CA1 region increased with stimulus intensity, as did the number of population spikes when the field recording electrode contained $10{\mu}M$ bicuculline. We measured the level of excitability in the CA1 area, using a paired-pulse stimulus paradigm to evoke population spikes. Population spikes showed strong paired-pulse inhibition at short interstimulus intervals. Burst afterdischarges up to 400 ms were observed after paired-pulse stimulus. These result suggest that hippocampal CA1 inhibitory interneurons can affect the excitability of pyramidal neurons that can not be appreciated in conventional in vitro preparation.

  • PDF

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

The immediate effect of electrical muscle stimulation on rectus femoris thickness during resisted knee extension exercise (전기근육자극을 적용한 무릎 폄 저항운동 시 넙다리곧은근의 두께 변화에 미치는 즉각적 효과)

  • Kim, Kang-hoon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.27-32
    • /
    • 2021
  • The purpose of this study was to compare the immediate effect of EMS (electrical muscle stimulation) on rectus femoris thickness during resisted knee extension exercise in healthy adults. This experiment was conducted on 20 healthy adults as pretest-posttest nonequivalent one group design. The subject's 1RM of both knee extension was measured indirectly using an elastic band, and the knee extension resistance exercise using an elastic band was applied to high intensity (80% of 1RM) on the right leg and low intensity (50% of 1RM with EMS) on the left leg, which were applied with 5 sets. Muscle measurements were performed on the rectus femoris (1/2 site, 1/4 site) using ultrasonography before and after exercise. There was a statistically significant difference on the thickness of the rectus femoris in low intensity exercise of the elastic band applied with EMS between pre-test and post-test (p<.05). The results of this study showed that elastic band low intensity exercise combined with EMS had an immediate effective in increasing the thickness of rectus femoris. Based on this result, it is also necessary to verify the effectiveness of intervention methods incorporating low-intensity resistance exercises applying EMS to elderly who cannot exercise high-intensity resistance training in the future, and to develop exercise programs for various body parts.

Development of a Musculoskeletal Model for Functional Electrical Stimulation - Noninvasive Estimation of Musculoskeletal Model Parameters at Knee Joint - (기능적 전기자극을 위한 근골격계 모델 개발 - 무릎관절에서의 근골격계 모델 특성치의 비침습적 추정 -)

  • 엄광문
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.293-301
    • /
    • 2001
  • A patient-specific musculoskeletal model, whose parameters can be identified noninvasively, was developed for the automatic generation of patient-specific stimulation pattern in FES. The musculotendon system was modeled as a torque-generator and all the passive systems of the musculotendon working at the same joint were included in the skeletal model. Through this, it became possible that the whole model to be identified by using the experimental joint torque or the joint angle trajectories. The model parameters were grouped as recruitment of muscle fibers, passive skeletal system, static and dynamic musculotendon systems, which were identified later in sequence. The parameters in each group were successfully estimated and the maximum normalized RMS errors in all the estimation process was 8%. The model predictions with estimated parameter values were in a good agreement with the experimental results for the sinusoidal, triangular and sawlike stimulation, where the normalized RMS error was less than 17%, Above results show that the suggested musculoskeletal model and its parameter estimation method is reliable.

  • PDF

Estimation of Causal Connectivity between Cortical Areas Using Near-Infrared Spectroscopy (NIRS) (근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석)

  • Lee, Seung-Deok;Go, Dal-Gwon;Jeong, Yeong-Jin;Kim, Do-Won;Im, Chang-Hwan;Kim, Beop-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.151-152
    • /
    • 2009
  • 최근 신경과학 분야에서 대뇌피질 영역 간 연관성 분석은 신경학적 질병 (자폐증, 간질, 정신 분열증)의 분석 및 진단에 적용되고 있다. 기존 대뇌피질 영역 간 연관성 분석은 뇌전도 (EEG), 기능적 자기공명영상 (fMRI), 뇌자도 (MEG)등이 이용되었지만, 뇌전도의 낮은 공간분해능, 기능적 자기공명영상의 낮은 시분해능 등은 영역 간 연관성 분석에 단점으로 작용되고 있다. 반면, 근적외선 분광법(NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxy-hemoglobin)를 비침습적이며 빠른 시분해능으로 측정할 수 있는 방법으로 최근 신경과학 분야에 응용되고 있다 [1-2]. 본 논문에서는 근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석의 효용성을 입증하기 위해, 쥐의 수염자극 시 대응되는 지역 (일차-, 이차 체감각피질, 일차 운동피질 영역)에서의 혈류변화 신호의 영역 간 연관성 분석을 하였다. 본 연구결과에 의하면 수염자극 시 일차-, 이차 체감각피질 영역에서의 방향성은 확인할 수 없었고, 일차-, 이차 체감각피질 영역에서 일차 운동피질영역으로의 방향성은 확인할 수 있었다. 본 결과는 기존 수염자극 시 활성화되는 전기신호의 패턴과 일치하며, 향후 신경과학적 질병의 분석 및 진단에 근적외선을 이용한 대뇌피질 영역 간 연관성 분석이 유용할 수 있음을 보여준다.

  • PDF

The Effect of Lower Extremity Muscle Strengthening Exercise using Biofeedback System on Lower Extremity Function and Gait in Community-based Elderly (바이오피드백 시스템을 활용한 하지근력 강화운동이 지역사회기반 노인의 하지기능과 보행에 미치는 효과)

  • Park, Tae-Sung;Lee, In-Sook;Jang, Myung-Hun;Shin, Myung-Jun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.1
    • /
    • pp.195-202
    • /
    • 2020
  • This study is to investigate the effect of lower extremity strength exercise using biofeedback system on community-based elderly. Ten community-based elderly were exercised using the biofeedback system (with functional electrical stimulation) three times a week for six weeks. Data analysis was performed using Wilcoxon signed rank test. Physical function improved significantly, but there was no significant difference in muscle strength and muscle mass. Although elderly people were able to confirm that community-based ICT home biofeedback training could be possible and could lead to improvements in the lower extremity function, further research is needed to demonstrate a clearer effect by expanding the target population, distinguishing the sexes, and providing a personalized training method.

A Study on the High Sensitivity Electrical Muscle Stimulation (EMS) Pad Using E-TEXTILE (E-TEXTILE을 이용한 고감성 전기 근육 자극(EMS)패드의 연구)

  • Yeun, Eun-Ji;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.3
    • /
    • pp.81-90
    • /
    • 2021
  • EMSCT (Electrical Muscle Stimulation Conductive Textile) is an electrical muscle stimulation pad that can compensate for ease of use and comfort, which are disadvantages of conventional hydrogel pads used in electrical muscle stimulation (EMS). With the concentration with SWCNT (Single-Walled Carbon Nanotube) and the number of impregnation processes, EMSCT was tested by giving conductivity to five fabrics (radirons, neoprene, spandex cushions, poly100%, and vergamo). The padding process with SWCNT was performed, and the alternating current measurement indicated that the most similar alternating current with hydrogel was the Vergamo fabric of SWCNT:=2:1. Furthermore, the usability evaluation of convenience, usability, and psychological satisfaction results in increased usability of EMSCT compared with conventional hydrogel pads.