• Title/Summary/Keyword: 기기 성능(instrument performance)

Search Result 19, Processing Time 0.321 seconds

위성 영상 탑재체에 관련된 영상품질 인자의 특성

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.66-74
    • /
    • 2002
  • The characteristics of the satellite image quality parameters driven by satellite imaging instrument are investigated. Since the satellite image is directly produced by the satellite imaging instrument, the satellite image quality depends on the imager performance highly. This is why the imager performance parameters are considered as an important part of the satellite image quality parameters. The imager performance parameters consist of spectral band parameters, ground sample distance(GSD) parameters, swath width parameters, imager Modulation Transfer Function (MTF), imager Signal to Noise Ratio(SNR), radiometric response characteristics parameters, pixel registration, and imager calibration.

  • PDF

A Study on the Problem and Improvement of Fire Detector Test in the Field Inspection (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Cha, Ha-Na;Ok, Kyung-Jae;Kim, Shi-Kuk;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.50-53
    • /
    • 2008
  • This study has been conducted for the purpose of considering the problems expected when checking the smoke detector at site and how to improve the smoke detector. We have conducted this study focused on checking the problems expected upon site inspection and finding out the way of improving the site inspection by analyzing the reliability and performance of instrument used upon site inspection. The test results show that some problems exist in the reliability and performance of instrument used for the site inspection of smoke detector way of inspecting the inspection instrument.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

The Proposed Validation Guidelines and Their Application for Performance Verification of UV-VIS Spectrophotometer (UV-VIS 분광기기의 성능검증을 위한 밸리데이션 가이드라인의 제정 및 응용)

  • Jin, Jing-Yu;Kang, Young-Koo;Lee, Won-Jae
    • YAKHAK HOEJI
    • /
    • v.50 no.3
    • /
    • pp.154-159
    • /
    • 2006
  • For the increasing demand for the validation of analytical results, one of the important concerns of the analyst is to be assured that the instrumentation is working to qualified conditions. In this study, we have investigated and compared several validation guidelines of the performance verification of UV-VIS spectrophotometer used in pharmacopoeias of major countries and UV-VIS instrument analytical companies, and we proposed the practically useful validation guidelines of UV-VIS spectrophotometer. Based on our proposed validation guidelines of UV-VIS spectrophotometer, several UV-VIS spectrophotometers used in drug manufacturing laboratories were validated for their performances.

Robust Object Tracking System Based on Face Detection (얼굴검출에 기반한 강인한 객체 추적 시스템)

  • Kwak, Min Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • Embedded devices with the development of modern computer technology also began equipped with a variety of functions. In this study, to provide a method of tracking efficient face with a small instrument of resources, such as built-in equipment that uses an image sensor in recent years has been actively carried out. It uses a face detection method using the features of the MB-LBP in order to obtain an accurate face, specify the region (Region of Interest) around the face when the face detection for the face object tracking in the next video did. And in the video can not be detected faces, to track objects using the CAM-Shift key is a conventional object tracking method, which make it possible to retain the information without loss of object information. In this study, through the comparison with the previous studies, it was confirmed the precision and high-speed performance of the object tracking system.

An Instrument for Continuous Measurement of Double Layer Capacitance (이중층 전기용량 연속 측정 장치)

  • Czae Myung-Zoon;Woo Seung-Soo;Choi Q. Won
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.674-678
    • /
    • 1992
  • An instrument is described that can obtain directly the whole capacitance vs. potential curve and accurately even in dilute solutions using positive feedback for IR correction. Applying a small (7∼10 mV) triangular signal, controlled rectification of the resulting square wave using sample-and-hold circuit allows one to plot the corrected double layer capacitance over a wide potential range. Several illustrations involving the improved performance characteristics of its applicability are given and its limitations discussed.

  • PDF

The Influence of Eccentric Error in Horizontal Angle Measurement (수평각관측에 있어서 구심오차가 관측치에 미치는 영향)

  • 이계학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1991
  • The accidential errors of horizontal angles are influenced by sighting, reading and eccentric errors etc. This paper deals with the influence of eccentric error by the formula of theory and evaluation, and actually testing measurement. The results show that the eccentric error is calculated through the sighting distance, observed angle, eccentric distance and angle. And then, three repeating method is of practical use, and also, eccentric error is able to evaluate through the sighting distance and observed angle in according to performance of each instrument.

  • PDF