• Title/Summary/Keyword: 근거리 측정

Search Result 324, Processing Time 0.037 seconds

Techniques of deformations measurement in Electric Power structure by using Close Range Photogrammetry (근거리사진측량을 이용한 전력구조물의 미소변위 측정기법)

  • 김감래;김명배
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.1
    • /
    • pp.77-87
    • /
    • 1994
  • One of the often espoused merits of close-range photogrammetry is the effectiveness of the method for measuring non-accessible objects of unusual and complex shape. In this study, techniques of deformation measurement using close-range photogrammetry for electric power structures were developed. Absolute deformation could be found efficiently through close-range photogrammetry in the structure deformation analysis based on time variation. Also, feasibility of the structures management system was presented based on this study.

  • PDF

Far-Field Sound Field Estimation from Near-Field Sound Field Data Using Boundary Collocation Method ; Decision of Optimum Points of Measurement (경계 배치법(Boundary Collocation Method)에 의한 근거리 음장 자료로부터 원거리 음장의 예측 ; 최적 측정점 개수의 결정)

  • 김원호;윤종락
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.31-37
    • /
    • 1999
  • This paper describes the far-field estimation using the near-field measurement data. Measurement in far-field region gives us the acoustical characteristics of the source but in general measurement is made in near-field such as acoustic water tank or anechoic chamber, so far-field acoustical characteristics of the source should be predicted from near-field data. In this case, the number of measurement points in the near field which relates to the accuracy of the predicted field and the amount of data processing, should be optimized. Existing papers say that measurement points is proportional to kL and depends on geometry and directivity of the source. But they do not give us any definite criterion for the required number of measurement points. Boundary Collocation Method which is one of the far-field prediction methods, is analyzed based on Helmholtz integral equation and Green function and it has been found that the number of measurement points is optimized as 0.54kL which is about one half of the existing results.

  • PDF

A Dosimeter System using a short distance radio communication (근거리 무선 통신을 이용한 선량계 구현)

  • Seo, Yong-Chil;Son, Jong-Dae;Lee, Heung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.571-573
    • /
    • 2004
  • 본 논문에서는 휴대용 선량계 시스템에 거리 무선 통신 방식중 Bluetooth를 이용하여 선량계를 구현한 것에 대해 논하였다. 휴대용 선량계란 감마선과 속중성자 및 열중성자를 현장에서 실시간으로 측정 할 수 있는 기기이다. 휴대용 선량계는 선랑계의 소형화를 위해 모듈별로 구성하여 공간의 최적화를 취하였다. 모듈의 구성은 시스템의 전반적인 제어를 하는 CPU부 센서로부터 측정한 데이터를 처리하는 신호처리부 방사선량을 측정하는 센서부로 구성되어졌다. 센서 모들의 PIN 다이오드와 MODFET 센서를 이용하여 감마선, 속중성자, 열중성자를 측정한다. 휴대용 선량계를 관리하고 측정한 데이터의 백업 및 분석을 위하여 PC용 관리프로그램과 근거리 무선 통신(Bluetooth)을 사용하여 통신하도록 만들어 사용하였다. 측정 지역의 방사선량을 휴대용 선량계로 측정하여 PC용 관리프로그램에서 실시간으로 방사선량을 확인 할 수 있다.

  • PDF

A Study on Implementation of a Short Distance Wireless Transceiver System with Commercial RF Module (상용 RF 모듈을 이용한 근거리 무선 송수신 시스템 구현에 관한 연구)

  • 차용성;강성진;강병권
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.53-56
    • /
    • 2000
  • 본 논문에서는 ISM 대역에서 동작하는 상용화된 RF 모듈을 사용하여 근거리 통신용 송수신 시스템을 구현하고 그 특성을 측정하였다. 기저 대역 데이터를 발생시켜 RF 모듈에 연결하여 전송하고, 수신측에서는 RF 모듈에서 복조된 데이터를 오실로스코우프를 사용하여 확인하였다. 본 실험에서 사용한 RF 모듈은 424MHz부터 429MHz까지의 영역에서 동작하며, FM 방식을 사용한다. 본 대학의 산학협동관 건물내에서 측정한 결과 거리에 따른 신호 감쇠와 신호 수신 감도를 파악할 수 있었으며, 이를 이용하여 건물 내에서의 근거리 통신에 적용할 수 있음을 확인하였다.

  • PDF

Adoption of Wireless Near Field Communication Method in the Discharge Measurements using Microwave Water Surface Current Meter (전자파표면유속계를 이용한 유량측정시 근거리 통신의 적용)

  • Kim, Young-Sung;Yang, Jae-Rheen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1784-1788
    • /
    • 2008
  • 전자파표면유속계는 여러 측정지점을 가능한 신속하게 이동하면서 홍수시 유속을 측정하는데 그 목적이 있다. 또한 홍수시 유속은 시간대 별로 급격히 변하는 속성을 가지고 있으므로 유량측정 지점의 유량을 실시간으로 획득하기 위해서는 현장 측정에서 측정한 유량데이터가 실시간으로 집계 되어야한다. 현재의 시스템은 측정 정보를 실시간으로 전송하기 위하여 현장 측정자에게 PDA가 보급되어 있으며 CDMA망을 통해서 유량 측정을 위한 각종 정보 및 측정결과를 실시간 전송하도록 되어있다. 그러나 전자파표면유속계를 비롯한 각종 유속계가 PDA와 무선으로 통신을 할 수 있게 되어있지 않기 때문에 열악한 여건의 현장에서 측정한 데이터를 야장에 수기로 기록한 후 이를 다시 PDA에 수동으로 입력시켜야하는 불편함이 있다. 전자파표면 유속계를 제외한 다른 측정 장비는 제조회사가 수자원공사와 독립적인 업체이므로 통신 접속을 하기위한 특정 인터페이스를 알아내기가 어려운 실정이다. 그러나 전자파표면유속계는 수자원공사에서 개발한 장비로서 핵심기술을 수자원공사에서 보유하고 있으므로 PDA와 통신을 가능하게 하는 장치의 개발이 가능하다. 이에 이러한 불편한 문제점을 개선하여 현장에서 홍수 유량 측정시 작업자들의 편이성을 증대시키고자 전자파표면유속계와 PDA간에 근거리통신기법을 적용하였다. 이를 위하여 Bluetooth, UWB(Ultra-Wide Band, 초광대역통신), Zigbee 등 적용가능한 근거리 통신기법을 조사하였다. 그 결과 Zigbee가 소비전력이 적어 현장에서 홍수유량측정에 이용되는 전자파표면유속계에 적용성이 가장 뛰어난 것으로 나타났다. 무선통신 모듈과 연동되는 전자파표면유속계는 이동식을 기준으로 적용하였으며 기존 신호처리부에 무선통신 모듈을 장착할 수 있는 구조로 설계하였다. 장착 방식은 기존 이동식 유속계의 신호처리부의 RS-232 포트에 무선통신 모듈을 장착하면 사용할 수 있는 구조로 되어있다. 신호처리부 RS-232 포트는 현재까지는 측정한 유속값을 PC로 전송받는 용도로 활용되었으나 무선모듈 장착 시에는 무선통신 할 수 있는 이중화 구조를 채택하였다. 두 가지 방식에 대한 통신구별은 초기에 송수신하는 데이터에 따라 구별되도록 하였다. 신호처리부에서 무선통신 추가에 따른 운용 방식은 별도의 수자원공사 모드를 추가하여 운용하도록 수정하였다. 유속 측정 시에는 무선통신 모듈을 제거한 상태에서 측정한 후, 측정한 데이터를 PDA로 전송할 때 아를 부착하여 사용할 수 있는 구조를 갖도록 제작하였다. 이러한 방식을 적용시킨 이유는 기존에 보급된 유속계에 무선모듈을 장착한 후, 신호처리부 운용 프로그램을 업그레이드하면 바로 사용할 수 있도록 하기 위함이다.

  • PDF

Relationship of Fixation Disparity and Heterophoria According to Fixation Distance (원, 근거리에서 주시시차와 사위와의 관계)

  • Kim, Chang-Jin;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • Purpose: This study measured Y-intercept that means a fixation disparity, X-intercept that means a associated phoria and slope of a fixation disparity curve (FDC), which are variables of dissociated phoria and the FDC. We searched for the result value and examined the direction, distribution pattern and a variable that give an most affect on dissociated phoria and the FDC at distance and near. Also this study examined that there were statistically significant differences between distance and near, comparing the result value. Methods: We measured the dissociated phoria and the fixation disparity for 51 subjects at distance and near in June, 2007. All subjects ranged from 20 to 25 years of age (average 21.72${\pm}$1.88 years old) and had no eye disease. At distance the dissociated phoria measured with the distance MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the modified Mallett Far Unit (Bernell co., USA). At near the dissociated phoria measured with the near MIM card (muscle imbalance measure card, Bernell co., USA), and the fixation disparity measured with the Wesson fixation disparity card (American Optical co., USA). Results: The percentage distribution of types of fixation disparity curves was that at distance prevalence of Type I (74.6%) was the highest, followed by Type IV (17.6%) and Type II (3.9%), Type III (3.9%) and that at near prevalence of Type I (53.0%) was the highest, followed by Type III (29.4%), Type IV (13.7%) and Type II (3.9%). 2. There were significantly correlation in dissociated phoria, fixation disparity (Y-intercept) and associated phoria (X-intercept). 3. The fixation disparity at distance was most affected by associated phoria (X-intercept) (p=0.000). The distance dissociated phoria was most affected by fixation disparity (Y-intercept) (p=0.342), but the influence was weak. 4. The fixation disparity at near was most affected by associated phoria (X-intercept) (p=0.000). The near also dissociated phoria was most affected by associated phoria (X-intercept) (p=0.009). The result that compared the each variables with the same variables at distance and near had statistically significant on paired t-test for among dissociated phoria (t=7.529, p=0.000), X-intercept (t=5.860, p=0.000), the Y-intercept (t=4.640, p=0.000) but slope of the FDC did not differ significant (t=1.336 p=0.188). Conclusions: Relationship of fixation disparity and Heterophoria had close correlation at distance and near.

  • PDF

Measurement and analysis of the near-field HRTFs for virtual audio enhancement (가상음장 재현을 위한 근거리 머리전달함수 측정 및 해석)

  • Shin Ki H.;Park Youngjin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.335-338
    • /
    • 2004
  • 효과적인 가상음장 재현을 위한 머리전달함수(Head Related Transfer Function: HRTF) 측정 시도는 1994년에 이루어진 MIT의 Bill Gardner에 의한 KEMAR 머리전달 함수 측정 이후 이미 여러 차례에 걸쳐 이루어졌다. 그러나 대부분의 시도는 음원이 머리중심점에서 1 m 이 후에 위치한 원거리에 국한되었고 음원이 1 m나 그 이내에 위치한 근거리에서의 측정은 스피커에서 반사된 음파가 dummy head 나 피험자의 귀에 다시 들어가는 것을 막기 어려워 시도된바가 적으며 data 도 공개되지 않은 것이 현 실정이다. 음원이 머리중심점에서 1 m 보다 가까운 거리에 있는 경우 머리전달함수의 특성은 고도와 방위뿐만 아니라 거리에도 영향을 받는 것으로 알려져 있으며, 이를 알아보기 위해 무향실에 B&K HATS (Head and Torso Simulator)를 설치하고 단극음원에 가까우며 반사가 적은 스피커를 따로 제작하여 근거리 머리 전달함수를 측정하였고 이를 분석하였다.

  • PDF

Numerical analysis for nearfield measurement error in a three-dimensional intensity probe. (3차원 인텐시티 프로브의 근거리 음장 측정에서의 오차 수치해석)

  • Kim, Suk-Jae;Jee, Suk-Kun;Suzuki, Hideo;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • We studied an inherent error be caused by a measuring acoustic intensity using probe which can measure simultaneously the three-dimensional acoustic intensity. This three-dimensional intensity probe was constructed with four microphones, proposed by Suzuki et al. . In the computer simulation, we analyzed the nearfield measurement error with arbitary direction and each of axis direction on the ideal point source and the plate sound source which have finite size. From the results, in case of point source, we obtained accurate measurement below about 1dB when the distance of measurement was about 2.5 times with the distance among microphones in this probe. And in the case of plate sound source, the nearfield measurement error was decreased as the length of one side became above 0.02m, we obtained accurate measurement below about 1dB when the length of one side is 0.2m. The nearfield measurement error of finite size sound is small to ignore. Therefore this probe is useful to measure nearfield intensity.

  • PDF

Enhancement Technologies of Signal-to-Noise Ratio in the Near-Field Scanning Systems (근거리 전자장 스캐닝 시스템의 잡음 대 성능 비 향상 기술)

  • Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.510-513
    • /
    • 2018
  • Recently, EMC (electromagnetic compatibility) becomes very important, which demands the measurement of EMI (electromagnetic interference) in the chip level. NFS (near-field scanning) systems defined in IEC 61967 and IEC 62508 are typical methods to analyze EMI in the chip level. As chips becomes faster, frequency measurement of NFS system should become wideband, but it degrades SNR (singal-to-noise ratio) of the NFP (near-field probe). This paper surveys SNR enhancement technologies of the NFS while maintaining wideband characteristics.

Far-Field Radiated Noise From Near-Field Measurement (근거리 음장 측정을 통한 원거리 음장 예측에 관한 스피커 실험)

  • Kim Tae-Jin;Son Keun-Young;Shin Hyun-Oak;Yoon Jong-Rak
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.125-128
    • /
    • 1999
  • 근거리음장 측정으로부터 원거리음장을 예측할 수 있는 이론적 모델 및 실험적 연구가 수행되고 있다. 본 논문에서 채택한 방법은 Helmholtz 적분식의 간단한 모델로써 단일주파수 코히어런트 음원의 근거리측정음장으로부터 원거리음장 예측이 가능한 기술이다. 이러한 단일 주파수, 코히어런트 음원의 원거리 수평방향지향성을 예측하기 위한 모델식 및 무향실에서 수행한 검증실험 결과를 소개한다 제안된 방법은 일반 소음원은 물론 잠수함 등의 수평방향 지향성의 예측에 적용가능하다고 판단된다.

  • PDF