• Title/Summary/Keyword: 극한상태

Search Result 307, Processing Time 0.026 seconds

The Current Methods of Landslide Monitoring Using Observation Sensors for Geologic Property (지질특성 관측용 센서를 이용한 산사태 모니터링 기법 현황)

  • Chae, Byung-Gon;Song, Young-Suk;Choi, Junghae;Kim, Kyeong-Su
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.291-298
    • /
    • 2015
  • There are many landslides occurred by typhoons and intense rainfall during the summer seasons in Korea. To predict a landslide triggering it is important to understand mechanisms and potential areas of landslides by the geological approaches. However, recent climate changes make difficult to predict landslide based on only conventional prediction methods. Therefore, the importance of a real-time monitoring of landslide using various sensors is emphasized in recent. Many researchers have studied monitoring techniques of landslides and suggested several monitoring systems which can be applicable to the natural terrain. Most sensors of landslide monitoring measure slope displacement, hydrogeologic properties of soils and rocks, changes of stress in soil and rock fractures, and rainfall amount and intensity. The measured values of each sensor are transmitted to a monitoring server in real-time. The ultimate goal of landslide monitoring is to warn landslide occurrence in advance and to reduce damages induced by landslides. This study introduces the current situation of landslide monitoring techniques in each country.

Characteristics of Submarine's Turbulent Wake using Analytical Solution of B(ξ) for the given λ (임의 λ에 대한 근사해 B(ξ)를 이용한 잠수함 난류항적 특성 연구)

  • Lee, Yong-Chol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1604-1610
    • /
    • 2017
  • Using analytical solution of $B({\xi})$, I could find out the characteristics of Submarine's turbulent wake for the given various ${\lambda}$, which were unknown facts before. As the results, $B({\xi}){\approx}{\frac{B({\xi})_{max}}{2}}$ and ${{\int}_{0}^{{\approx}0.6}}B({\xi})d{\xi}{\approx}0.85{{\int}_{0}^{1}}B({\xi})d{\xi}$ in the vicinity ${\xi}{\approx}0.6$, there was some dependencies on the given ${\lambda}$ though. The values of ${\lambda}$, in the range of $4{\leq}{\lambda}{\leq}8$, are more suitable to describe submarine's turbulent wake realistically, due to the bases on the quasi equilibrium state of turbulent wake. ${\lambda}$ mainly affects on the radius and detection range of the submarine's turbulent wake on the surface, however, the speed of submarine mainly affect on the duration of the wake rather than shape. If $7{\leq}{\lambda}{\leq}8$, it can be expected that the turbulent wake can be seen on the surface in the West sea, however, snorkeling(or snorkeled) submarine's wake can be found easily in the East sea.

Test of Hypothesis in Assessing Process Capability Index Cpmk (공정능력지수 Cpmk를 평가함에서의 바람직한 가설검정)

  • Cho, Joong-Jae;Yu, Hye-Kyung;Hana, Jung-Su
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.3
    • /
    • pp.459-471
    • /
    • 2010
  • Higher quality level is generally perceived by customers as improved performance by assigning a correspondingly higher satisfaction score. Usually, the quality level is measured by process capability indices. The index is used to determine whether a production process is capable of producing items within a specified tolerance. The third generation index $C_{pmk}$ is more powerful than two useful indices $C_p$ and $C_{pk}$. which have been widely used in six sigma industries to assess process performance. Most evaluations on process capability indices focus on point estimates, which may result in unreliable assessments of process performance. In this paper, we consider better testing procedure on assessing process capability index $C_{pmk}$ for practitioners to use in determining whether a given process is capable. It is easy to use the proposed method for assessing process capability index $C_{pmk}$. Whether a process is clearly normal or nonnormal, our bootstrap testing procedure could be applied effectively without the complexity of calculation. A numerical result based on our proposed method is illustrated.

Pathways to homelessness: The case of young adults in Korea (남성 청년의 노숙진입 시기에 따른 노숙 경로)

  • Kim, Soyoung
    • Korean Journal of Social Welfare Studies
    • /
    • v.47 no.4
    • /
    • pp.151-181
    • /
    • 2016
  • The objective of the study is to identify the sub-path of entry into homelessness of young men and enhance understanding them. In specific, homeless risk factors were extracted through their experiences, and based on which the entry paths into homelessness were drawn. The homeless young adults were divided into two groups of those who became homeless in their adolescence and those who entered into homelessness after 19 and their differences were analyzed. As a results, the most prominent differences between the two sub-groups included individual and social factors; most of those who entered homelessness after 19 had physical or psychological problems, while the other group showed delinquency factors in adolescence and adulthood. As for social factors, the former group experienced more financial damage in the process of achieving independence before being homeless, while the latter group had relatively more experience of physical and psychological damage such as bullying, harassment and violence before being homeless and financial frauds. As for investigating the causality relationship of key homeless risk factors by adding a variable of time, and based on which, a constant pattern of entry paths toward homelessness was drawn among each sub-group of homeless young adults. For policy on homelessness, it is required to develop according to the characteristics of homeless young adults. Especially, a specific approach is necessary for the different homeless pathways by sub-group. Furthermore, the study indicated that management and preemptive responses for various homeless risk factors that homeless young adults experienced throughout their lifetime could be important prevention policy against homelessness.

Compressive and Flexural Properties of Concrete Reinforced with High-strength Hooked-end Steel Fibers (고강도 후크형 강섬유로 보강된 콘크리트의 압축 및 휨 성능)

  • Wang, Qi;Kim, Dong-Hwi;Yun, Hyun-Do;Jang, Seok-Joon;Kim, Sun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.209-217
    • /
    • 2021
  • This paper investigates the effect of high strength hooked-end steel fiber content and aspect ratio on the compressive and flexural performance of concrete. A total of ten mixtures were prepared and tested. Concretes with specific compressive strength of 30 MPa were reinforced with three different aspect ratios (l/d) of steel fibers 64, 67, and 80 and three different percentages of steel fibers 0.25, 0.50, and 0.75% by volume of concrete. Tensile strengths of steel fibers with l/d of 64, 67, and 80 are 2,000, 2,400, and 2,100 MPa, respectively. The compressive and flexural properties of plain and steel fiber-reinforced concrete (SFRC) mixtures were evaluated and compared. The experimental results indicated that the incorporation of high-strength hooked-end steel fibers had significant effects on the compressive and flexural performance of concrete. With the increase of steel fiber content, compressive performances, such as Poisson's ratio and toughness, of concrete were improved. The steel fibers with the least l/d of 67 resulted in a larger enhancement of compressive performances. The residual flexural strength, that is, post-cracking flexural resistance and toughness, of concrete is mainly depended on the dosage and aspect ratio of steel fibers. The residual flexural strength at serviceability (SLS) and ultimate limit state (ULS) defined in fib Model Code 2010 (MC2010) is increased as the fiber content and aspect ratio increase.

Hydrological Drought Analysis and Monitoring Using Multiple Drought Indices: The Case of Mulrocheon Watershed (수문학적 가뭄감시 및 해석을 위한 다양한 가뭄지수 평가 -물로천 유역을 중심으로-)

  • Lee, Joo-Heon;Park, Seo-Yeon;Kim, Min Gyu;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.477-484
    • /
    • 2021
  • Due to climate change, parts of Korea are experiencing large and small droughts every 2-3 years and extreme droughts every 7 years. Since most droughts occur mainly in areas where small water supply facilities in the tributaries or upstream are located, more research on technology for securing water in these areas is required. In this study, a drought evaluation using SPEI (Standardized Precipitation Evapotranspiration Index), SDI (Streamflow Drought Index), and WBDI (Water Budget-based Drought Index) was performed to investigate hydrological drought in the Mulrocheon watershed of Chuncheon, a vulnerable area in terms of water supply. As a result of calculating hydrological drought indices SPEI and SDI, examining each duration, it was confirmed that the common drought in 2014 did not recover and continued until 2015. In the hydrological drought index evaluation result by WBDI, a very severe drought condition was observed in the spring of 2015 following 2014, and that drought was the most severe at -1.94 in November 2017. As a result of deriving a SDF (Severity-Duration-Frequency) curve through frequency analysis by duration using the drought index calculated on a monthly basis from 2003 to 2019 (17 years), most droughts in the Mulrocheon watershed were found to have a return period of less than 10 years, but droughts that occurred in 2014, 2015, and 2019 were found to cover more than 20 years, respectively.

Flexural Behavior of Concrete Beams Reinforced with Fe based Shape Memory Alloy Bar (철계-형상기억합금 바로 제작된 콘크리트 보의 휨 거동)

  • Hong, Ki-Nam;Yeon, Yeong-Mo;Ji, Sang-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.67-76
    • /
    • 2020
  • This paper reports an experimental study to evaluate the flexural behavior of concrete beams reinforced using Fe based shape memory alloy (Fe-SMA) bars. For the experiment, a concrete beam of 200mm×300mm×2,200mm was produced, and a 4% pre-strained Fe-SMA bar was used as a tensile reinforcement. As experimental variables, type of tensile reinforcement (SD400, Fe-SMA), reinforcement ratio (0.2, 0.39, 0.59, 0.78), activation of Fe-SMA (activation, non-activation), and joint method of Fe-SMA bar (Continuous, welding, coupler) were considered. The electric resistance heating method was used to activate the Fe-SMA bar, and a current of 5A/㎟ was supplied until the specimen reached 160℃. After the upward displacement of the specimen due to the camber effect was stabilized, a three-point flexural loading experiment was performed using an actuator of 2,000 kN capacity. As a result of the experiment, it was found that the upward displacement occurred due to the camber effect as the Fe-SMA bar was activated. The specimen that activated the Fe-SMA bar had an initial crack at a higher load than the specimen that did not activate it. However, as with general prestressed concrete, the effect of the prestress by Fe-SMA activation on the ultimate state of the beam was insignificant.

Experimental Study on the Strengthening Effect of External Prestressing Method Considering Deterioration (구조물 노후도를 반영한 외부긴장 보강 효과에 관한 실험적 연구)

  • Kim, Sang-Hyun;Jung, Woo-Tai;Kang, Jae-Yoon;Park, Hee-Beom;Park, Jong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Concrete structures gradually age due to deterioration of materials or excess loads and environmental factors, and their performance decreases, affecting the usability and safety of structures. Although external tension construction methods are widely used among the reinforcement methods of old bridges, it is insufficient to identify the effects and effects of reinforcement depending on the level of aging. Therefore, in this study, a four-point loading experiment was conducted on the subject with the non-reinforced and external tensioning method to confirm the reinforcement effect of the external tensioning method, assuming the aging of the structure as a reduction in the compressive strength and tensile reinforcement of concrete, to analyze the behavior of the reinforcement and confirm the reinforcement effect. As a result of the experiment, it was difficult to identify the amount of reinforcement in the extreme condition due to early elimination of the anchorage. Therefore, compliance with the regulations on anchor bolts is required when applying the external tension reinforcement method. Crack load and yield load increased depending on whether external tension was reinforced, but before the crack, the stiffness before and after reinforcement was similar, making it difficult to confirm the reinforcement effect.

Numerical Simulation of 72m-Long Ultra High Performance Concrete Pre-Stressed Box Girder (72m 초고강도 콘크리트 프리스트레스트 박스 거더의 수치 해석)

  • Mai, Viet-Chinh;Han, Sang Mook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.73-82
    • /
    • 2022
  • The study presents a three-dimensional approach to simulate the nonlinear behavior of a 72 m long Ultra High Performance Fiber Reinforced Concrete (UHPFRC) pre-stressed box girder for a pedestrian bridge in Busan, South Korea. The concrete damage plasticity (CDP) model is adopted to model the non-linear behavior of the UHPFRC material, in which the material properties are obtained from uniaxial compressive and tensile tests. The simulation model based on the proposed stress-strain curve is validated by the results of four-point bending model tests of a 50 m UHPFRC pre-stressed box girder. The results from the simulation models agree with the experimental observations and predict the flexural behavior of the 50 m UHPFRC pre-stressed box girder accurately. Afterward, the validated model is utilized to investigate the flexural behavior of the 72 m UHPFRC pre-stressed box girder. Here, the load-deflection curve, stress status of the girder at various load levels, and connection details is analyzed. The load-deflection curve is also compared with design load to demonstrate the great benefit of the slender UHPFRC box girder. The obtained results demonstrate the applicability of the nonlinear finite element method as an appropriate option to analyze the flexural behavior of pre-stressed long-span girders.

Structural Performance Evaluation of Offshore Modular Pier Connection using Ultra-high Performance Concrete (초고성능 콘크리트를 활용한 해상 모듈러 잔교 연결부의 구조성능 평가)

  • Lee, Dong-Ha;Kim, Kyong-Chul;Kang, Jae-Yoon;Ryu, Gum-Sung;Koh, Kyung-Taek
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.351-357
    • /
    • 2022
  • In this study, offshore modular pier system using the ultra-high performance concrete was developed for the offshore construction environment. For the application of offshore modular pier system, the design, fabrication, and construction performance evaluation were performed using ultra-high performance concrete a compressive strength 120 MPa or more and a direct tensile strength 7 MPa or more. For offshore piers previously constructed with precast concrete, it was intended to verify the idea and possibility of solving errors due to position or vertical deformation during the driving of the foundation pile part during the construction stage. Furthermore, a offshore modular pier system was fabricated with ultra-high performance concrete for the construction performance evaluation. The results showed that a offshore modular pier system secured about 9 % of sectional performance of load bearing capacity under ultimate load conditions. If the offshore modular pier system developed through this study is utilized in the future, it is judged that competitiveness due to sufficient durability and constructability can be secured.