• Title/Summary/Keyword: 균일분포

Search Result 1,486, Processing Time 0.024 seconds

Design and Dose Distribution of Docking Applicator for an Intraoperative Radiation Therapy (수술중 방사선치료를 위한 조립형 조사기구의 제작과 선량 분포)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, John-Kyu
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.123-130
    • /
    • 1991
  • A docking intraoperative electron beam applicator system, which is easily docking in the collimator for a linear accelerator after setting a sterilized transparent cone on the tumor bearing area in the operation room, has been designed to optimize dose distribution and to improve the efficiency of radiation treatment method with linear accelerator. This applicator system consisted of collimator holder with shielded metals and docking cone with transparent acrylic cylinder, A number of technical innovations have been used in the design of this system, this dooking cone gives a improving latral dose coverage at therapeutic volume. The position of $90\%$ isodose curve under suface of 8 cm diameter cone was extended $4\sim7$ mm at 12 MeV electron and the isodose measurements beneath the cone wall showed hot spots as great as $106\%$ for acrylic cone. The leakage radiation dose to tissues outside the cone wall was reduced as $3\sim5\%$ of output dose. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented.

  • PDF

Effect of Concentration of Polyacrylic Acid and Sulfate ion on the Cystal growth - A Topographic Study (법랑질표면에서 폴리아크릴산용액 농도와 황산이온 농도가 결정형성에 미치는 영향)

  • Kim, Joo-Hyung;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.877-891
    • /
    • 1998
  • This study was designed to observe the effects of various concentration of polyacrylic acid containing different concentration of sulfate ion on the crystal formation on the enamel surface. Experimental crystal growth solutions were made of $10\%,\;20\%,\;30\%\;and\;40\%$ polyacrylic acid(molecular weight,5,000) solutions which containing 0.1M, 0.2M, 0.3M, 0.5M, and 1.0M sulfate ion respectively. The extracted human first bicuspid enamel surface was contacted for n seconds with these solutions, washed for 15 seconds, dried, and then the crystal topography on the enamel surface was observed under the scanning electron microscope. The crystal topography were evaluated on the SEM photographs by degree of crystal coverage, crystal length, and consistency of crystal morphology, and conclusions were as the follows. 1. Polyacrylic acid solution etched slightly the enamel surface, and the difference of etching effect by its concentration was not observed. 2. The effect of concentration of polyacrylic acid on the crystal formation was less, especially that of $20\%\~40\%$ polyacrylic acid was almost not different. 3. Concentration of the sulfate ion was a determinant factor in precipitating crystals on the enamel. The experimental crystal growth solutions containing 0.1 M sulfate ion did not make crystal formation but those containing over 0.2 M sulfate ion did. 4. The degree of crystal coverage showed a tendency to increase and then decrease according to the concentration of sulfate ion in the $20\%-40\%$ polyacrylic acid. The experimental solutions containing 0.5 M sulfate ion showed the peak of degree of crystal coverage. 5. The crystal length showed a tendency to decrease by increment of sulfate ion in the polyacrylic acid solution. 6. There was a tendency to increase the frequency of random arragement of short crystals when increasing the concentration of sulfate ion in the polyacrylic acid solution. The lower concentration of sulfate ion in the polyacrylic acid solutions tended to make spherulitic arrangement of crystals, the higher concentration of sulfate ion, the more random arrangement of crystals. The experimental solutions containing 0.5M sulfate ion showed more spherulitic arrangement than random arrangement of crystals. 7. The best one of these experimental crystal growth solutions was $30\%$ polyacrylic acid solution containing 0.5M sulfate ion.

  • PDF

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

A Study on the Improvement of Skin-affinity and Spreadability in the Pressed Powder using Air Jet Mill Process and Mono-dispersed PMMA (Air Jet Mill 공법과 PMMA의 단분산성이 프레스드 파우더의 밀착성 및 발림성 향상에 대한 연구)

  • Song, Sang Hoon;Hong, Kyong Woo;Han, Jong Seob;Kim, Kyong Seob;Park, Sun Gyoo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • The key quality attributes of the pressed powder, one of base makeup products, are skin-affinity and spreadability. In general, there was a limit to meet skin-affinity and spreadability simultaneously, which are opposite attributes each other. In this study, air jet mill process was tried to satisfy two main properties. Skin-affinity was improved by a wet coating of sericite with a mixture of lauroyl lysine (LL) and sodium cocoyl glutamate (SCG). The application of mono-dispersed polymethyl methacrylate (PMMA) and diphenyl dimethicone/vinyl diphenyl dimethicone/silsesquioxane crosspolymer (DDVDDSC) improved both qualities. Air jet mill process has been mainly applied in the pharmaceutical and food industries, and is a method used for processing powder materials in cosmetic field. In this study, we were able to complete makeup cosmetics with an optimum particle size $6.8{\mu}m$ by combining the air jet mill process at the manufacturing stage. It was confirmed that the Ti element was uniformly distributed throughout the cosmetics by EDS mapping, and that the corners of the tabular grains were rounded by SEM analysis. It is considered that this can provide an effect of improving the spreadability when the cosmetic is applied to the skin by using a makeup tool. LL with excellent skin compatibility and SCG derived from coconut with little skin irritation were wet coated to further enhance the adhesion of sericite. SEM images were analyzed to evaluate effect of the dispersion and uniformity of PMMA on spreadability. With the spherical shapes of similar size, it was found that the spreading effect was further increased when the distribution was homogeneously mono-dispersed. The dispersion and spreadability of PMMA were confirmed by measuring the kinetic friction and optimal content was determined. The silicone rubber powder, DDVDDSC, was confirmed by evaluating the hardness, spreading value, and drop test. Finally, it was found that the dispersion of PMMA and silicone rubber powder affected spreadability. Such makeup cosmetics have excellent stability in drop test while having appropriate hardness, and good stability over time. Taken together, it is concluded that air jet mill process can be utilized as a method to improve skin-affinity and spreadability of the pressed powder.

A STUDY ON THE MAXIMUM BITE FORCE AND FACIAL MORPHOLOGY ACCORDING TO CHEWING SIDE PREFERENCE (저작습관에 따른 교합력과 안면골격형태의 비교연구)

  • Jeong, Mi-Ra;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.311-321
    • /
    • 1995
  • This study was undertaken to investigate the distribution of the chewing side preference and variations in the maximum bite force and facial morphology according to chewing side preference since unilateral chewing may cause morphologic and functional anomalies. 50 dental students who had no signs or symptoms of masticatory system and Angle's Class I relationship in posterior segments were selected, and divided into two groups, that is, 25 in bilateral chewing group(19 male and 6 female) and 25 in unilateral chewing group(10 male and 15 female). Maximum bite force was estimated ana posteroanterior cephalogram were measured ana statistically analyzed. The results were as follows : 1. Their were more students with bilateral chewing side preference($68\%$) and unilateral chewing side group consisted of right side preference($68\%$) and left side preference($32\%$). 2. There was no significant difference in the strength of max. bite force between the right and left side in bilateral chewing group. The bite force of the chewing side nab greater in the unilateral chewing group but less in the non-chewing side compared to those of bilateral chewing group with Bo significant difference. Max. bite force of chewing side was greater than that of non-chewing side in the unilateral chewing group(Female p<0.05). Max. bite force of males was about twice in that of females in both groups(p<0.05). Max. bite force of chewing side of the unilateral chewing group was similar to that of the bilateral chewing group, but that of non-chewing side was less than that of the bilateral chewing group. 3. In comparison of the facial morphology, there was no statistically significant difference in the size between the right and left side of the bilateral chewing group and between chewing and non-chewing side of the unilateral chewing group.

  • PDF

A Study on Temperature Change Profiles by Land Use and Land Cover Changes of Paddy Fields in Metropolitan Areas (대도시 외곽지역 논경작지의 토지이용 및 피복변화에 따른 온도 변화모형 연구)

  • Ki, Kyong-Seok;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • The purpose of this study is to understand the scale of temperature change following large-scale urban developments in paddy fields to present possible measures to preserve suburban area paddy fields and to lower the scale of temperature increase after developing paddy fields in urban areas. The study was conducted in Bupyeong and Bucheon of Incheon Metropolitan City. The satellite image($1989{\sim}2000$) before and after the development of old paddy fields were used to analyze the land surface temperature changes according to the land use types. Building coverage, green coverage, non-permeable pavement coverage, and floor area ratio(FAR) were selected as the factors that influence urban temperature changes and the temperature estimation model was constructed by using correlation and regression analyses. The before and after satellite images of Bupyeong and Bucheon were classified into forests, greens and plantations, paddy fields, unused lands, and urban areas. The results indicate that most of the paddy fields that existed in the center of Bupyeong and Bucheon were converted into unused lands which were undergoing construction to become new urban areas. The difference between the surface temperatures of May 17th, 1989 and May 7th, 2000 was analyzed to reveal that most land converted from paddy fields to unused lands or urban areas saw an increase in surface temperature. Han River was used as a comparison to analyze the average surface temperature changes($1989{\sim}2000$) in former paddy fields. The scale of temperature changes were: $+1.6697^{\circ}C$ in urban parks; $+2.5503^{\circ}C$ in residential zones; $+2.9479^{\circ}C$ on public lands, $+3.0385^{\circ}C$ in commercial zones, and $+3.1803^{\circ}C$ in educational zones. The correlation between building coverage, green coverage, non-permeable pavement coverage, or floor area ratio(FAR) and surface temperature increases was also analyzed. The green coverage to temperature increases, but building coverage, non-permeable pavement coverage, and floor area ratio(FAR) had no statistically significant temperature increases. The factors that influence urban temperature changes were set up as independent variables and the surface temperature changes as dependent variables to construct a surface temperature change model for the land use types of former paddy fields. As a result of regression analysis, green coverage was selected as the most significant independent variable. According to regression analysis, if farmland is converted into an urban area, a temperature increase of $+3.889^{\circ}C$ is anticipated with 0% green coverage. The temperature saw a decrease of $-0.43^{\circ}C$ with every 10% increase of green coverage.

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF