• Title/Summary/Keyword: 구면렌즈

Search Result 137, Processing Time 0.037 seconds

Aspherical Lens Design and Development of Spherical Aberration Measuring System by use of Spherical Aberration (구면 수차를 이용한 비구면 렌즈의 설계와 수차 측정 장치 개발)

  • Park, Kyu-Yeol;Kim, Han-Seob
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.175-180
    • /
    • 2007
  • In this paper, an aberration free aspherical lens is designed and machined by new design method and the spherical aberration measuring system is developed. It confirmed the propriety of new design method by measuring optical characteristics of machined lens with the new measuring system. The system could measure a spherical aberration quantitatively by using CCD camera, laser, collimator and so on.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

Lens design for microdisplay system (마이크로디스플레이의 렌즈 설계)

  • 김혜경;신승연;박광범;최성호;문현찬
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.08a
    • /
    • pp.212-213
    • /
    • 2001
  • 본 논문에서는 마이크로디스플레이용 광학계의 렌즈 설계와 시뮬레이션으로 구면수차, 비점수차, 왜곡, 색수차를 보정하여 설계한 광학계의 성능 평가를 소개하고자 한다.

  • PDF

A Study of Abnormal Refraction Eye on the 30's employees (30대 직장인의 굴절이상안에 대한 연구)

  • Lee, Young-Il;Lee, Young-Dal
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.115-119
    • /
    • 2001
  • To research the refractive error of the eyes on the 30's employees, 510 eyes were tested by the object and subject methods. The results were as follows. 1. Among the 510 eyes, myopia is 74.4%, hyperopia is 0.9% and emmetropia is 24.7%, respectively. 2. In test, the low myopia (-0.50Dt < Spherical Equivalent ${\leq}$ -2.00Dt) is 24.1%, the middle myopia(-2.00Dt < Spherical Equivalent ${\leq}$ -6.00Dt) is 51.4%, the high myopia(-6.00Dt < Spherical Equivalent) is 14.8% and the low hyperopia(+0.50Dt < Spherical Equivalent ${\leq}$ +2.00Dt) is 1.2%, respectively. 3. In test of astigmatism, the amount of astigmatism with-the rule is 58.5%, the amount of astigmatism against-the rule is 22.6% and the amount of astigmatism with oblique is 18.9%, respectively.

  • PDF

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Implementation of 3D Undistorting Algorithm for Stereo Camera (스테레오 카메라를 위한 렌즈 왜곡 및 3차원 자세 보정 알고리즘 개발)

  • Lee, Seung-Min;Lee, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1850_1851
    • /
    • 2009
  • 본 논문에서는 스테레오 카메라를 이용한 대상물체의 3차원 정보 추출 및 가시화를 위하여 우선적으로 실시해야 하는 카메라 대한 렌즈 왜곡 보정 및 3차원 자세 보정알고리즘의 적용에 대하여 살펴보았으며, 렌즈의 왜곡 보정 부분에서는 렌즈의 구면 수차로 인한 왜곡은 각 카메라에 대하여 패턴 영상을 획득한 후 렌즈왜곡보정계수를 산출하여 왜곡 보정 실시하였다. 더불어 보정을 통하여 보다 입체감 있는 영상의 출력이 가능함을 확인할 수 있었다.

  • PDF

3. 최신 기술 동향 - 비구면 렌즈, 회절광학소자 동향

  • 이종웅
    • The Optical Journal
    • /
    • v.13 no.1 s.71
    • /
    • pp.39-42
    • /
    • 2001
  • 국내 광학산업계에서 결상광학계에 대한 기술은 구면 광학계를 위주로 하고 있고, 소형 플라스틱 렌즈분야에서 비구면의 활용이 일반화되어 가고 있다. 앞으로 고성능 결상광학계를 중심으로 유리 비구면 렌즈의 활용이 늘어날 것으로 예상돼 유리비구면 렌즈의 성형기술의 개발이 필요하다. 또한 비구면 플라스틱렌즈의 경우 비구면의 면정도를 0.1$\mu$m 수준으로 높여야 하며, 이를 위해 탐침법에 의한 기계적 형상측정에서 간섭계를 이용하는 정밀한

  • PDF

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Measurement of Small Aspheric Lens Using the Spherical Interferometer (구면 간섭계를 이용한 소형 비구면 렌즈 검사 방법에 관한 연구)

  • Jang, Nam-Young;Park, Kwang-Hee;Song, Hui-Young;Choi, Pyung-Suk;Eun, Jae-Jeong;Seo, Jung-Rang
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1589_1590
    • /
    • 2009
  • 본 논문에서는 구면 렌즈 검사를 위해 제작된 Fizeau형 위상 천이 간섭계(Fizeau-type Phase Shifting Interferometer : FPSI)에 비구면 해석 알고리즘을 적용한 소형 비구면 렌즈 해석 방법을 제안한다. 또한 본 논문에서 제안한 방법의 측정 결과와 기존 비구면 검사 시스템의 측정 결과를 비교하여 그 성능을 평가한다.

  • PDF