• Title/Summary/Keyword: 구내 방사선

Search Result 100, Processing Time 0.022 seconds

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

A comparison of periapical radiographs and their digital images for the detection of dental caries (인접면 치아우식증의 진단의 치근단 X선사진과 디지털영상의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.31-35
    • /
    • 1994
  • 전남대학교 치과진료처에 내원한 환자의 구내방사선사진중 1단계 (Cl: 30개 병소)또는 2단계(C2: 213.8병소)의 인접면 치아우식을 가진 방사선사진 168장을 연구대상으로 하였다. 이들 방사선사진은 코닥사의 Ektaspeed(E group) 필름을 사용하여 평행촬영법으로 촬영하였다. 168장의 방사선사진에 대하여 1단계 및 2단계 치아우식증을 4명의 구강악안면방사선학을 전공한 치과의사들이 같이 판독하여 그 결과를 기록하였다. 또한 168장의 방사선사진을 필름-비디오 변환장치를 이용하여 디지털 영상으로 전환하였다. 이때 486 DX PC에 PCVision과 frame grabber를 이용하였다. 각각의 구내방사선사 진영상은 17"크기의 1280×768픽셀의 해상도를 갖는 모니터상에서 256단계 흑화도를 갖는 700×480픽셀로 제시되었다. 모니터상에서의 치아우식 판독 결과를 구내방사선사진 판독 결과와 비교하였다. 그 결과 sensitivity는 0.98이었다. 1단계 치아우식은 0.87, 2단계 치아우식 은 1.00의 sensitivity를 나타내었다.

  • PDF

Comparison Study of Textbook and Actual Clinical Incidence Angles in Intra-Oral Radiology Examinations (구내 방사선 검사에서 교과서와 실제 임상의 입사각도 비교연구)

  • Hyun-Jun Ahn;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.483-490
    • /
    • 2024
  • Existing Intra-oral radiography examinations have problems with information on the angle of incidence used in textbook and those used in the field, and radiologic examinations result vary depending on the operator's skill. Therefore, this study aimed to suggest an ideal angle of incidence for radiological examination so that the proximal areas between teeth are clearly visible without overlapping. First, patient's dental arch in the exact center, and the angle of incidence of the point where the teeth did not overlap was measured using a protractor tool in program. Second, based on the calculated results, we surveyed patient phantoms for student practice during Intra-oral radiography examination and conducted a survey based on qualitative evaluation using a 5-point Likert scale.When comparing the average value obtained by measuring actual patient data and the angle specified in the existing reference book, there is a statistically significant difference in the average between the two groups at p < 0.05 in the proximal area of all teeth, and even if the gender and age group are different, there is a significant difference. Because it did not deviate from the scope, we were able to obtain results that could be sufficiently presented as guidelines. In addition, in a qualitative evaluation based on the images presented by applying the actual measured data to the phantom, images were obtained in which the adjacent surfaces of teeth do not overlap. In conclusion, this study proposes guidelines for the angle of incidence during Intra-Oral Radiography examination to reduce cone-cut images or images with overlapping proximal area and prevent repeat.

Effects of Recombinant Human Epidermal Growth Factor (rhEGF) on Experimental Radiation-Induced Oral Mucositis in Rats (Rat의 방사선 조사성 구내염에 대한 Recombinant Human Epidermal Growth Factor (rhEGF)의 효과)

  • Jung Kwon-Il;Kim Sun-Hee;Moon Soo-Young;Kim Yeon-Wha;Hong Joon-Pio;Kim Hyun-Sook;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2006
  • Purpose: Oral mucositis is a common toxicity of radiation or chemotherapy, which is used a treatment for head and neck cancer. We investigated effects of recombinant human epidermal growth factor (rhEGF) on radiation-induced oral mucositis in rat model. Materials and Methods: Spraque-Dawley rats (7 per group) exposed to a single dose of 25 Gy (day 0) on their head, except for one group, were randomly divided into un-treated, vehicle-treated, and two rhEGF-treated groups. Rats were topically applied with rhEGF (15 or $30{\mu}g/oral$ cavity/day) or vehicle to their oral mucosa. Survival rate of rats, weight changes, and food intakes were examined from day 0 to 18 after radiation. Histology study was performed from oral mucosa of rats at day 7 and 18 after radiation. Results: rhEGF-treated groups (15 or $30{\mu}g/oral$) showed all survival rate 33%, whereas un-treated and vehicle-treated groups showed all survival rate 0% at the end of experiment. rhEGF-treated groups statistically had less weight loss compared to vehicle-treated group from day 2 to 7 after radiation. Food intake of rats with rhEGF treatment turned to increase at day 14 after radiation. At 7 day after radiation, un-treated and vehicle-treated groups showed severe pseudomembraneous or ulcerative oral mucositis. On the other hand, rhEGF-treated groups had no more than cellular swelling and degeneration of epidermal cells in oral mucosa of rats. Conclusion: These results suggest that rhEGF has significantly positive effects on radiation-induced oral mucositis in rats. rhEGF display a therapeutic potential on a clinical level.

Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator (구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성)

  • Lee, Kyung Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.465-471
    • /
    • 2012
  • In this study, three dimensional X-ray dose distribution from dental X-ray generator system was measured by ALOKA PDM-117 dosimeter. The X-ray dose distribution will be change with XCP-DS FIT in oral shot, because the distance between X-ray generator and the dosimeter. The X-ray dose change affects on patient exposure and radiograph image quality. Therefore, it is important to obtain relation between the X-ray dose and the distance. The X-ray dose at the central position was decreased with increasing the distance. Furthermore, the dose at the edge of the X-ray flux was increased with increasing the distance. The increased dose affects on the patient radiation exposure. The present results will provide for good dental radiograph image and reducing radiation over-exposure on patient.

A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface calculus (구내방사선사진과 컴퓨터영상의 치아 인접면 치석 진단능의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 1994
  • 전남대학교 치과대학 학생을 대상으로 평행촬영법으로 촬영한 168장의 구내방사선사진을 디지털 영상으로 변환하여, 필름상의 치석 유무 판독 결과와 모니터상의 판독 결과를 비교하였다. 3명의 구강악안면방사선학 전공 치과의사가 판독을 하되 필름상의 판독 결과를 판정의 기준으로 하였다. 디지털 영상은 상업용 필름-비디오 변환장치, 486DX PC, 그리고 PcVision과 frame grabber을 이용하여 얻었다. 모니터상의 개개 구내방사선사진상은 700×480 pixel로 나타내었다. 디지털 영상의 치석진단의 sensitivity는 0.79-0.90(평균 0.86) 이었고, specificity는 0.03-0.43(평균 0.17) 이었다.

  • PDF