• Title/Summary/Keyword: 교합접촉

Search Result 159, Processing Time 0.029 seconds

Finite Element Analysis of Stress Distribution around the Micro-Patterned Implants (마이크로패터닝을 부여한 임플란트 주변골에서의 하중 분포에 관한 유한요소분석법적 연구)

  • Hur, Bae-Young;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2008
  • Implant requires long lasting, strong osseointegration using bio-mechanical interlocking by bone ingrowth. In regarding the size level for bone ingrowth, the micro-patterning would enhance bone response. Micro-patterning can increase the area contacting the bone tissues. Therefore, it may distribute the load to the surrounding bone tissue, more effectively. This study compared and analyzed the load distributing effect with the shape and number of micro-patterning. For the optimal comparison of threads, the assumptions different from general finite element analysis model were made. It was assumed that the implant was axisymmetric and infinitely long. The implant was assumed to be completely embedded in the infinitely long cortical bone and to have 100% bone apposition. The implant-bone interface had completely fixed boundary conditions and received an infinitely big axial load. The condition of threads were as follows. The reference model 1 had conventional thread. Model 2 had 2 micro-patterns on the upper flank of the thread. Model 3 had 2 micro-patterns on the lower flank of the thread. Model 4 had 2 micro-patterns on the upper and lower flanks of the thread. Model 5 had 3 micro patterns on the upper and lower flanks of the thread. The results were as follows: 1. The thread with micro-patterns distributed stress better than the conventional thread. 2. The thread with micro-patterns on the lower flank distributed stress better than that with micro-patterns on the upper flank. 3. The thread with 3 micro-patterns distributed stress better than that with 2 micro-patterns, However, an area with stress concentration occurred.

Full mouth rehabilitation in partially edentulous patient with an unstable mandibular position (불안정한 하악위를 가진 부분 무치악 환자에서 전악 수복 증례)

  • Donghwi Yook;Younghoo Lee;Seoung-Jin Hong;Ahran Pae;Kwantae Noh;Hyeong-Seob Kim;Kung-Rock Kwon;Janghyun Paek
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.308-315
    • /
    • 2023
  • In the case of a patients who have lost the centric stop and have a staggered occlusion of the residual teeth, various movements occur when the denture is loaded. Implant placement is necessary to reinforce the retention, support, and stabilization elements to reduce denture movement. However, in this case, considering the patient's age, aversion to surgery, and bone loss, implants were not placed and restoration was performed with a removable partial denture. In this case, it is important to set the correct mandibular position for restoration because the patient has a habit of chewing with the remaining teeth. In this case, a stable mandibular position was established using a gothic arch tracing, and good results were obtained by restoring with partial dentures, so this is reported.

A STUDY OF THE OCCLUSAL CONTACT PATTERN DURING MANDIBULAR MOVEMENTS OF ADULT WITH NORMAL OCCLUSION (T-scan을 이용한 성인정상교합자의 하악운동시 치아접촉양상에 관한 연구)

  • Chai Young-Ah;Park Nam-Soo;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.565-579
    • /
    • 1993
  • This study was accomplished to analyse and compare the occlusal contact patterns during eccentric mandibular movements in adult with normal occlusion. 50 subjects(male 27, female 23), who had natural occlusion and no symptom of temporomandibular disorder, were selected. Teeth contact patterns during mandibular eccentric movements were recorded and the distribution of tooth contacts in maximum intercuspation analysed by T-scan system. And then, tooth contact numbers recored by T-scan and silicone bite registration at centric occlusion were analysed and compared. The results obtained were as follows : 1. Antero-posteriorly, the qualitative center of occlusal contacts in centric occlusion were in the first molar areas, but there was a slight deviation in left-right directions. Thus, distribution of occlusal contacts were not bilaterally symmetric. 2. During the mandibular movements from centric occlusal position to right lateral and left lateral directions, the frequency that maxillary canine joined in lateral guidance was relatively high, but pure canine protected occlusion or pure group function occlusion had small frequency. 3. During mandibular protrusive movement, one or more maxillary central incisors frequently joined in protrusive guidance. 4. During mandibular eccentric movements, working and balancing side premature contact was observered in relatively high frequency. 5. In centric occlusal position, the numbers of occlusal contacts recorded on T-scan were relatively smaller than on silicone bite registration.

  • PDF

A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns (교모면적과 교합접촉양태 간의 관계에 대한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

Case of making maxillary palatal augmentation complete denture for patient with dysphagia after partial glossectomy (부분 혀 절제술로 인해 연하 장애가 있는 환자에서 상악 구개 증대 총의치 제작 증례)

  • Kim, Hyung-Seok;Park, Ji-Young;Yim, Sun-Young;Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.239-245
    • /
    • 2018
  • If complication arises after glossectomy which leads to trouble in forming food bolus or transfer of the food, it is possible that either food bolus may block the airway or dysphagia may occur as the food bolus goes down into the airway. To solve the issue, palatal augmentation prosthesis could be used. In this case, the patient with an oral cancer is having difficulties swallowing food after glossectomy. Through taking impressions of polishing surface of his denture referring his tongue movement, the complete denture for the upper jaw was created using the concept of palatal augmentation prosthesis. This new upper denture increases the palatal-tongue contact pressure, allowing the patient to perform better swallowing and better pronunciation.

The Infection Control of Dental Impressions (치과용 인상체의 감염 관리)

  • Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.183-193
    • /
    • 2013
  • The characteristics of dental treatment makes the dental staff frequently contact with patient directly. Also the daily use of high-handpieces, sharp instruments, and needles often causes bleeding on oral cavity. Therefore, the risk of cross transmission grows up. The pathogen from dental practice could spread on not only the practice itself but also the dental laboratory with contaminated impressions and prosthesis. Dental clinic staffs (dentists, dental hygienists and dental technicians) should recognize all the patients have a possibility of cross contamination, and try to prevent the transmission of infection by proper infection control. In this study, we review the articles about disinfection methods and chemical infection agents used for dental impressions, and try to figure out the suitable and effective infection control system of dental impressions.

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.