• Title/Summary/Keyword: 교체용

Search Result 318, Processing Time 0.034 seconds

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Sludge reduction by Enzyme Pretreatment (효소 전처리를 통한 슬러지 저감)

  • 김정래;심상준;최수형;염익태
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.93-97
    • /
    • 2004
  • We investigate the effect of enzyme pretreatment using protease, carbohydrase, and lipase on improvement of sludge treatment efficiency by measuring SCOD and TCOD. The enzyme-pretreatment increases SCOD of excess sludge. In addition, the amount of sludge reduction during digestion, in terms of SCOD and TCOD, are enhanced by enzyme-pretreatment. Among pretense, carbohydrase, and lipase, pretense showed the best enhancement of the sludge treatment efficiency. Sludge digestion followed by ozone and enzyme treatments showed more effective sludge treatment when compared with ozone treatment alone. Therefore, we expect that enzyme pretreatment can be used as a useful tool for enhancing the sludge treatment efficiency.

Electricity Demand in the Korean Households-A Technology/Sustainable Option- (우리 나라 가정부문 전력수요에 관한 연구-기술개발/지속적 개발 시나리오)

  • 박희천
    • Journal of Technology Innovation
    • /
    • v.2 no.1
    • /
    • pp.1-57
    • /
    • 1994
  • 본 고는 지속적 개발 론에 입각한 적극적인 에너지수요 관리정책을 추진한다는 전제하에 2001년과 2006년의 우리 나라 가정부문 전력수요를 전망하고자 한다. 본 고는 지속적 개발 시나리오를 추정함에 있어서 기존의 계량모형보다 일종의 공학적 모형인 공정분석(process analysis)을 선호한다. 계량모형이 주로 과거 수요의 소득 및 가격 탄성 치를 바탕으로 미래의 수요를 예측하는데 비하여 공정분석모형은 기술발전에 따른 미래의 효율변화(향상)를 비교적 잘 반영할 수 있기 때문이다. 본 고는 덴마크공과대학교 Norgard 교수팀이 개발한 모형을 도입하여 분석모형(수식 (6))을 전력수요 = 기기 수 $\times$ 전력서비스$\times$ 전력집약도와 같이 설정하고 이를 사용하여 냉장고, 텔레비전, 조명 기기, 난방기기 등과 같은 전력사용 기기 별로 2001년과 2006년이 전력수요를 전망하였다. 본 고는 전력수요를 전력사용 기기의 사용용량(300리터 용량의 냉장고 등)과 사용시간을 나타내는 전력서비스와 전력 서비스당 필요 전력사용량을 나타내는 전력집약도로 나누어 구분하고 있는 모형을 이용함으로써 소득향상효과와 함께 기술발전에 따른 효율개선효과를 분석할 수 있다. 1) 생활수준 향상에 따라 전력서비스는 지금과 같이 증가한다, 2) 현실적으로 가능한 범위 내에서 전력사용 기기에 대한 최저 에너지 효율 제를 실시한다, 3) 현재 사용중인 기기 들은 원칙적으로 수명이 다한 후 고효율 기기 들로 자연 교체한다, 4) 최저 에너지 효율 제를 제외한 다른 제도 및 정책개선, 사용자의 에너지소비형태 개선에 따른 절전 잠재 량을 고려하지 않는다 등의 가정 하에 전력수요를 추정한 결과 1992년에 796 GWh(100)이었던 우리 나라 가정부문 전력수요는 2001년과 2006년에 29,237 GWh(134)와 33,118 GWh(152)로 각각 34%와 52%증가할 것으로 나타났다. 이 경우 1992년부터 2006년까지 가정용 전력수요 증가율은 연평균 3%로 추정된다. 기기의 서비스(가구수$\times$기기의 보급 율$\times$기기의 전력서비스)가 소득향상에 따라 증가하는데도 불구하고 전력수요의 증가율이 GDP(같은 기간 동안 연평균 증가율 5.7%)보다 매우 낮은 것은 기기의 대형화와 기기의 보급을 증가에 따른 전력의 추가수요가 기기의 에너지효율 개선으로 대부분 상쇄될 것이기 때문이다. 향후 10년 내에 기기에 따라 전력사용량을 25%~50%정도까지 줄일 수 있을 것으로 분석된다. 기술발전에 따른 기기의 에너지효율 개선효과는 본 고의 2006년도 가정용 전력수요의 전망치 33,118 GWh가 기존방식에 의한 한전의 전망치 61,155 GWh의 54%수준밖에 되지 않는데 서도 잘 나타나고 있다. 한편 본 고는 경제성장과 환경보존을 동시에 달성할 수 있는 지속적 개발의 실천방안으로서 에너지 수요관리를 논하고자 한다. 고효율 기기의 개발과 조기도입을 촉진시키는 에너지 수요관리 통하여 우리는 에너지효율을 대폭 개선시키며 대기오염 배출량도 대폭 줄일 수 있다. 본 고는 에너지 공급관리(공급확충)위주에서 에너지 수요관리위주로서의 에너지정책 전환은 불가피하다고 판단한다. 에너지 공급시스템보다 에너지 수요시스템위주로 전체 에너지시스템을 획기적으로 개선시키기 위해서는 최저 에너지효율제의 광범위한 실시와 함께 고효율 기기의 개발과 보급에 필요한 유인책의 도입, 고효율 기기와 에너지의 효율적 이용에 대한 정보 등이 필요시 되고 있다. 우리 나라의 경우 현재의 산업구조와 기술수준을 고려하여 에너지 효율의 기준을 미국보다 다소 낮게 설정한다면 최저 에너지효율제의 도입이 문제가 되지 않을 것으로 판단된다. 본 고는 고효율 기기의 개발과 조기도입을 지원하기 위한 가칭 대기환경보존 및 에너지 수요관리기금의 창설을 제안한다. 전력부문의 경우 기금은 1. 탄소세, 2. 전력소비에 대한 수요 관리 세의 도입 혹은 3. 한국전력공사 전력판매수입의 일정 분으로 조성될 수 있을 것으로 본다. 예를 들어 선진국들이 탄소세를 예정대로 도입한다는 전제하에 우리 나라가 2000년을 기준으로 탄소 톤당 8달러(석유 배럴 당 85센트)의 탄소세를 도입한다면 연간 7억 2,000만 달러(약5,760억 원)규모의 기금을 조성할 수 있다. 이 중 연간 2,000억 원 정도를 고효율 기기의 개발과 조기도입에 지원한다면 우리 나라 에너지 시스템 효율은 대폭 개선될 수 있을 것으로 예상된다.

  • PDF

Mid-term Follow-Up Results of Cryopreserved Valved Conduit in RVOT Reconstruction (우심실 유출로에 사용된 냉동 동종 판막도관의 중기성적)

  • 장윤희;전태국;민호기;한일용;성기익;이영탁;박계현;박표원
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.384-390
    • /
    • 2003
  • Background: Since Ross and Sormeville first reported the use of aortic homograft valve for correction of pulmonary atresia in 1966, homograft valves are widely used in the repair of congenital anomalies as conduits between the pulmonary ventricle and pulmonary arteries. On the basis of these results, we have used it actively. In this report, we describe our experience with the use of cryopreserved valved homograft conduits for infants and children requiring right ventricle to pulmonary artery connection in various congenital cardiac anomalies. Material and Method: Between January, 1996 and December 2001, 27 infants or children with a median age of 16 months(range 9days to 18years) underwent repair of RVOTO using homograft valved conduit by two surgeons. We studied 22 patients who have been followed up at least more than one year. The diagnosis at operation included pulmonary atresia with ventricular septal defect (n=13), truncus arteriosus (n=3), TGA or corrected TGA with RVOTO (n=6). Homograft valved conduits varied in size from 15 to 26 mm (mean, 183.82 mm). The follow-up period ranged from 12 to 80.4 months (median, 48.4 months). Result: There was no re-operation due to graft failure itself. However, early progressive pulmonary homograft valve insufficiency developed in one patient, that was caused by dilatation secondary to the presence of residual distal pulmonary artery stenosis and hypoplasia after repair of pulmonary atresia with ventricular septal defect. This patient was required reoperation (conduit replacement). During follow-up period, there were significant pulmonary stenosis in one, and pulmonary regurgitation more than moderate degree in 3. And there were mild calcifications at distal anastomotic site in 2 patients. All the calcified homografts were aortic in origin. Conclusion: We observed that cryopreserved homograft conduits used in infant and children functioned satisfactorily in the pulmonic position at mid-term follow-up. To enhance the homograft function, ongoing investigation is required to re-establish the optimal strategy for the harvest, preservation and the use of it.

Dissemination of Bacillus Subtilis by using Bee-vectoring Technology in Cherry Tomato Greenhouses (방울토마토 시설재배에서 비벡터링(bee-vectoring) 기술을 이용한 Bacillus Subtilis 포장내 전파)

  • Park, Hong-Hyun;Kim, Jeong Jun;Kim, Kwang-Ho;Lee, Sang-Guei
    • Korean journal of applied entomology
    • /
    • v.52 no.4
    • /
    • pp.357-364
    • /
    • 2013
  • Bee-vectoring is a new crop protection technology used for suppressing insect pests and diseases in crops by disseminating microbial agents into plants during bee pollination activities. In this study, we conducted bee-vectoring trials in cherry tomato greenhouses by using the bumble bee (Bombus terrestris), a microbial agent (Bacillus subtilis) and a new dispenser, and we measured the delivered quantity of microbial agent. Bacterial colony forming units (CFUs) in bees exiting a dispenser ranged from $9.0{\times}10^5$ to $1.9{\times}10^6$ per bee. At greenhouse trials in the National Academy of Agricultural Science (NAAS) trials, 3,300 - 8,500 CFUs per flower were counted and 80 - 100% of the flower samples contained detectable concentrations. There was no significant difference in CFU density between microbial replacement intervals (once a week vs twice a week) in the NAAS trials. In a commercial greenhouse trial, 1,800 - 2,400 CFUs per flower were found, and 83 - 93% of the flower samples contained detectable concentrations. CFUs detected in bee-vectored flowers increased by approximately 75 times before bee-vectoring. The mortality of bumble bees in the NAAS trials was, on average, 22% and little negative effects were observed on the bumble bee colonies. The yield difference for cherry tomatoes in the NAAS trials was not significant between treatments. When we select additional microbial agents that can be disseminated using this technology and create a detailed plan based on insect pests and disease incidence, we can apply this technology in greenhouses for growing tomatoes and strawberries in the near future.

Effect of the Feeding Belly Fat on Plasma Lipids Levels in Rats (삼겹살기름의 섭취가 흰쥐의 혈액지질 수준에 미치는 영향)

  • 박병성
    • Food Science of Animal Resources
    • /
    • v.24 no.2
    • /
    • pp.189-197
    • /
    • 2004
  • This study investigated the effect of belly fat on the plasma lipid concentrations in rats. The results were obtained from the rats that had been fed the experimental purified diets containing 5% corn oil (C) as the control, 5% commercial lard (Tl), 5% belly fat (T2), 10% belly fat(T3), and those given diet(T4) by feeding either C or T3 alternately every 3 days for 30 days. The food intake and food efficiency were not show any significant difference among the treatments. The body weight gain tended to significantly increased when the feeding of added-belly fat in diets (p<0.05). The plasma triacylglycerides of T3 was higher than the other treatments, and significantly elevated as the number of feeding days of the diets with the belly fat passed when compared to diet C (p<0.05). The plasma total cholesterol of T3 showed the highest levels in the treatment groups, and was high in the order of T1, T2, T4, and there was a significant difference between the rats given the diet with belly fat and C (p<0.05). The plasma HDL-C of T2 and T3 was showed the lowest levels in the treatment groups. The plasma HDL-C of T1, T2, T3 and T4 groups were significantly decreased as the number of feeding days of the diets with the belly fat increased when compared to diet C (p<0.05). The plasma LDL-C and Al of T3 showed the highest levels in the treatment groups, and the levels were in order of T1, T2, T4. There was a significant difference between the groups of rats given the belly fat and C (p<0.05). The bleeding times significantly decreased as the number of feeding days of the belly fat diets increased, and T3 showed the lowest levels, there was a significant difference among the treatment groups (p<0.05). The whole blood clotting times of T3 showed the lowest values, and significantly decreased according to the number of days of the rats were fed the belly fat diet (p<0.05). These results showed that frequent consumption and high intake of pork belly can elevate the plasma triacylglyceride and cholesterol levels, and also accelerate red thrombus formation because belly fat contains high levels of saturated fatty acids and cholesterol.

Developing a Dental Unit Waterline Model Using General Laboratory Equipments (실험실 일반 장비를 이용한 치과용 유니트 수관 모델 개발)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Water supplied through dental unit waterlines (DUWLs) has been shown to contain high number of bacteria. To reduce the contamination of DUWLs, it is essential to develop effective disinfectants. It is, however, difficulty to obtain proper DUWL samples for studies. The purpose of this study was to establish a simple laboratory model for reproducing DUWL biofilms. The bacteria obtained from DUWLs were cultured in R2A liquid medium for 10 days, and then stored at $-70^{\circ}C$. This stock was inoculated into R2A liquid medium and incubated in batch mode. After 5 days of culturing, it was inoculated into the biofilm formation model developed in this study. Our biofilm formation model comprised of a beaker containing R2A liquid medium and five glass rods attached to DUWL polyurethane tubing. Biofilm was allowed to form on the stir plate and the medium was replaced every 2 days. After 4 days of biofilm formation in the laboratory model, biofilm thickness, morphological characteristics and distribution of the composing bacteria were examined by confocal laser microscopy and scanning electron microscopy. The mean of biofilm accumulation was $4.68{\times}10^4$ colony forming unit/$cm^2$ and its thickness was $10{\sim}14{\mu}m$. In our laboratory model, thick bacterial lumps were observed in some parts of the tubing. To test the suitability of this biofilm model system, the effectiveness of disinfectants such as sodium hypochlorite, hydrogen peroxide, and chlorhexidine, was examined by their application to the biofilm formed in our model. Lower concentrations of disinfectants were less effective in reducing the count of bacteria constituting the biofilm. These results showed that our DUWL biofilm laboratory model was appropriate for comparison of disinfectant effects. Our laboratory model is expected to be useful for various other purposes in further studies.

Availability and Reproducibility Evaluation of High-dose-rate Intraluminal Brachytherapy for Unresectable Recurrent Cholangiocarcinoma (재발한 간담도암 환자에서 시행 한 high-dose-rate intraluminal brachytherapy의 유용성 및 재현성 평가)

  • Park, Ju-Kyeong;Lee, Seung-Hun;Cha, Seok-Yong;Kim, Yang-Su;Lee, Sun-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • General treatment for cholangiocarcinoma is complete surgical resection. However recurrence is common in those patients. In most of cases the purpose of the treatment for patients with recurrent is palliative. Therefore we adopt intraluminal catheter to treat a recurrent patient with high-dose-rate intraluminal brachytherapy. This study aims to evaluate the treatment procedure and set-up reproducibility of intraluminal brachytherapy in the recurrent patient. Study patient was diagnosed at rcT1N0M0 and undergone intraluminal brachytherapy after Arrow Sheath insertion. 3 Gy was delivered in every fraction with a total dose of 30 Gy. We planned dose normalization at distal, proximal and central axis point of narrowed bile duct far from 1 cm. To evaluate set-up reproducibility, we measured distance between distal, proximal treatment target volume point and anterior surface of the thoracic vertebral body respectively for five times before every treatment with dummy seed insertion. Mean distance between distal, proximal treatment target volume point and anterior surface of 10th and 11th thoracic vertebral bodies is 0.5 cm, 6.1 cm and standard deviation is 0.06, 0.08 respectively. In addition, set-up reproducibility was maintained significantly. The patient has been alive with no evidence of disease recurrence for more than a year and has not yet reported severe complications. In conclusion, high-dose-rate intraluminal brachytherapy for unresectable recurrence of cholangiocarcinoma maintains high set-up reproducibility without severe side effects.

Establishment of a Dental Unit Biofilm Model Using Well-Plate (Well-Plate를 사용한 치과용 유니트 수관 바이오필름 모델 확립)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.17 no.4
    • /
    • pp.283-289
    • /
    • 2017
  • The water discharged from dental unit waterlines (DUWLs) is heavily contaminated with bacteria. The development of efficient disinfectants is required to maintain good quality DUWL water. The purpose of this study was to establish a DUWL biofilm model using well-plates to confirm the effectiveness of disinfectants in the laboratory. Bacteria were obtained from the water discharged from DUWLs and incubated in R2A liquid medium for 10 days. The bacterial solution cultured for 10 days was made into stock and these stocks were incubated in R2A broth and batch mode for 5 days. Batch-cultured bacterial culture solution and polyurethane tubing sections were incubated in 12-well plates for 4 days. Biofilm accumulation was confirmed through plating on R2A solid medium. In addition, the thickness of the biofilm and the shape and distribution of the constituent bacteria were confirmed using confocal laser microscopy and scanning electron microscopy. The average accumulation of the cultured biofilm over 4 days amounted to $1.15{\times}10^7CFU/cm^2$. The biofilm was widely distributed on the inner surface of the polyurethane tubing and consisted of cocci, short-length rods and medium-length rods. The biofilm thickness ranged from $2{\mu}m$ to $7{\mu}m$. The DUWL biofilm model produced in this study can be used to develop disinfectants and study DUWL biofilm-forming bacteria.

Deterioration Diagnosis and Source Area of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea (감은사지 서탑의 풍화훼손도 진단 및 석재의 산지추정)

  • Lee Chan Hee;Lee Myeong Seong;Suh Mancheol;Choi Seok-Won;Kim Man Gap
    • Economic and Environmental Geology
    • /
    • v.37 no.5
    • /
    • pp.569-583
    • /
    • 2004
  • The rock properties of the West pagoda in the Gameunsaji temple site are composed mainly of dark grey porphyritic granodiorite with medium grained equigranular texture and developed with small numerous dioritic xenoliths. These xenoliths occurred with small holes due to different weathering processes. As a weathering results, the rock properties of this pagoda occur wholly softened to physical hardness because of a complex result of petrological, meteorological and biological causes. Southeastern part of the pagoda deteriorated seriously that the surface of rock blocks showed partially exfoliations, fractures, open cavities in course of granular decomposition of minerals, sea water spray and crystallization of salt from the eastern coast. The Joint between blocks has small or large fracture cross each other, contaminated and corrupted for inserting with concrete, cement mortar, rock fragments and iron plates, and partially accelerated coloration and fractures. There are serious contamination materials of algae, fungus, lichen and bryophytes on the margin and the surface on the roof stone of the pagoda, so it'll require conservation treatment biochemically for releasing vegetation inhabiting on the surface and the discontinuous plane of the blocks because of adding the weathering activity of stones and growing weeds naturally by soil processing on the fissure zone. Consisting rock for the conservation and restoration of the pagoda would be careful choice of new rock properties and epoxy to reinforce for the deterioration surfaces. For the attenuation of secondary contamination and surface humidity, the possible conservation treatments are needed.