• Title/Summary/Keyword: 교차축

Search Result 107, Processing Time 0.028 seconds

The Effect of Aspect Ratio on the Flow Characteristics of Elliptic Jets (종횡비에 따른 타원제트의 유동특성에 관한 실험적 연구)

  • 권영철;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1156-1162
    • /
    • 1992
  • The effect of aspect ratio on the flow characteristics of elliptic jets was experimentally investigated. The flow characteristics of sharp-edged elliptic nozzles with aspect ratio of 1 (round nozzle), 2 and 4 were measured by using a 3-D LDV system along the major and minor axis at X/De = 2, 3, 5, 7 and along the centerline up to X/De = 14. At each measurement point mean velocites, turbulent intensities, skewness of three orthogonal velocity components, and Reynolds shear stress were obtained. The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter(De) was about 4 * 10$^{4}$. Difference in the spreading rate along the major and minor axis was remarkable. The jet half width along the major axis decreased at first and then increased again with going downstream. But the jet width along the minor axis increased steadly. The elliptic jet of AR = 2 had two switching points within the measurement range, while that of AR = 4 had only one. (AAA) : The elliptic jet of AR = 2 showed larger velocity decay rate than that of AR = 1 and AR = 4. The effect of aspect ratio on the flow characteristics of elliptic jets was dominant in the near jet regions of X/De < 7, and the skewness and Reynolds shear stress had quite different distribution depending on the aspect ratio of the elliptic nozzle.

Digital Linear Control System for a Magnetic Bearing System of a High Vacuum Turbomolecular Pump (고진공 터보 분자펌프용 자기베어링 시스템의 디지털 선형 제어시스템)

  • Ro, Seung-Kook;Kyung, Jin-Ho;Park, Jong-Kweon;Nam, Woo-Ho;Koh, Deug-Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.256-264
    • /
    • 2010
  • In this paper, a digital controller of magnetic bearing system for a high vacuum turbomolecular pump (TMP) is designed and examined. For stabilizing and providing damping in magnetic bearing, the digital PID controller is applied for each 5 control axes, and the inter-axis cross feedback controller is also applied to suppress low frequency vibration caused by gyroscopic moment of the rotor at high speed of rotation. The fabricated rotor-shaft has its first flexible natural frequency lower than maximum speed, about 614Hz, so the two lead filters are applied to increase damping of flexible mode. Notch filters with rotating frequency were selected to reduce vibration of the pump housing caused by unbalance load. The implemented controllers are verified by examination of frequency response and rotating test up to 40,000 rpm, which is higher than critical speed of backward flexible mode.

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF

Validation of PCR and ELISA Test Kits for Identification of Domestic Animal Species in Raw Meat and Meat Products in Korea (국내 유통 식육 및 식육가공품에서 축종감별을 위한 PCR 및 ELISA 검사법 검증)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Seo, Kun-Ho;Kim, Young-Jo;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.158-163
    • /
    • 2014
  • In this study, two commercial PCR and ELISA test kits were examined for identification of eight animal species (beef, pork, chicken, duck, turkey, goat, lamb, and horse) from raw meat and meat products in Korea. The detection limit in RAW meat ELISA kit$^{(R)}$ on three types of meat samples blended with beef, pork and chicken, demonstrated that all meat species were differentiable down to 0.2%. RAW meat ELISA kit$^{(R)}$ on animal species resulted in differentiation rate of 94.5% for beef, 93.3% for pork, 90% for lamb, and 100% for chicken, duck, turkey, goat, and horse. In contrast, Powercheck Animal Species ID PCR kit$^{TM}$ resulted in 100% specificity at 0.05% limit of detection for all meat species. The detection limit of Cooked Meat ELISA kit$^{(R)}$ on mixed meat samples heat-treated with different temperatures and times, resulted in 0.1% for all heat-treated mixed meat except for chicken at 1.0%. Additionally, ELISA kit on sixty meat products resulted in specificity of 31.8% for ham, 13.6% for sausages, and 12.5% for ground processed products, and relatively low rate for more than 2 types of mixed meats. On the contrary, meat species differentiation using PCR kit showed higher percentage than that using ELISA kit$^{(R)}$: 50.0% for ham, 41.7% for sausages, and 28.6% for ground processed meat. Futhermore, PCR kit on 54 dried beef meats detected pork genes in 13 products whereas ELISA kit showed negative results for all products. Hence, the possibility of cross-contamination during manufacturing process was investigated, and it was found that identical tumblers, straining trays, cutters and dryers were used in both beef and pork jerky production line, suggesting the inclusion of pork genes in beef products due to cross-contamination. In this study, PCR and ELISA test kits were found to be excellent methods for meat species differentiation in raw meat and heat-processed mixed meat. However, lower differentiation rate demonstrated in case of meat processed products raised the possibility of inclusion of other species due to cross-contamination during manufacturing process.

Uplink Pilot Signal Design for Mobile Wireless Backhaul (이동무선백홀을 위한 상향링크 파일럿 신호 설계)

  • Choi, Seung Nam;Kim, Ilgyu;Kim, Dae Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1005-1013
    • /
    • 2015
  • In this paper, an uplink pilot signal structure is proposed for millimeter wave(mmWave)-based mobile wireless backhaul. For the transmit diversity of two antenna ports, uplink pilot signals generated from the Zadoff-Chu sequence can be mapped in an interleaved mode or continuous mode on the frequency axis, and channel estimation algorithms are different depending on the pilot signal mapping schemes. Through a simulation under Rayleigh fading channel assuming a subway scenario, the interleaved mapping scheme showed no performance degradation compared to the continuous mapping scheme and the implementation complexity of the uplink channel estimator was reduced due to the interleaved mapping scheme.

Analysis of Cassegrain Dual Offset Reflectors for Compact Payload Test Range (CPTR용 카세그레인 오프셋 복 반사경의 해석)

  • Rho, Sung-Min;Choi, Hak-Keun;Lim, Sung-Bin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • In general, the cassegrain dual offset reflector is used for the satellite communication antenna, but is analyzed as the reflector system for the CPTR(Compact Payload Test Range) facility in here. The near-field at the test zone of the CPTR is obtained by using the physical optics approximation. The CPTR has to provide a uniform plane wave with the minimum amplitude and phase ripple and the low cross polarization. Therefore, in this paper, the near-field pattern are calculated, and the ripple and taper of the field and the cross polarization are investigated with the variation of the reflector geometry and the position of the test region. Especially, the cross polarization of the antenna axis direction which is not found in the satellite reflector antennas is investigated.

Technology Intelligence based on the Co-evolution Analysis : Semiconductor Package Process Case (공진화 분석기반 기술 인텔리전스 : 반도체 패키지공정 사례)

  • Lee, Byungjoon;Shin, Juneseuk
    • Journal of Technology Innovation
    • /
    • v.28 no.4
    • /
    • pp.63-93
    • /
    • 2020
  • We suggest a new way of specifying the co-evolution of product and process technologies, and integrating it into one of the well-received technology intelligence tools - a technology radar. Cross impact analysis enables us to identify the core technologies of product-process co-evolution. Combining expert judgment with its results, we can clarify the technological co-evolution trajectory with mainstream as well as emerging core technologies. Reflecting these in the assessment process of a technology radar, we could improve reliance of the technology assessment process and technology portfolio. From the academic perspective, our research provides a point where the co-evolution theory encouners technology intelligence methods. Practically, strategic capability of future-preparedness and strategic management could improve by adopting our method based on our example of co-evolution of semiconductor product and process technologies.

Rotor Dynamic Analysis of the High Speed Centrifugal Chiller (고속회전용 터보냉동기의 회전체 동역학 해석)

  • 이준근;박용석
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.193-198
    • /
    • 2003
  • A rotor dynamic analysis is implemented to confirm the vibration stability of the high speed centrifugal chiller coupled with gear system. As the rotating speed of the centrifugal chiller under investigated is increased up to 17,605 rpm at the pinion rotating part, the bearing instability is getting higher and, furthermore, the rotor-bearing system might experience a few critical speed which lead to system failure due to the excessive vibration. In this study, considering the loading capacity and stability conditions, offset journal bearings are adopted for the pinion rotating system and general cylindrical bearing are used for motor part. From the modal analysis, the system is found to be stable as the synchronous rotating frequency does not come across with any whirl natural frequency and, in addition, the critical damping ratio which shows the damping characteristics of the system are positive over the all operating ranges. From these results the authors confirm the vibration stability of the rotor-bearing system suggested in this study.

  • PDF

Six-axis Biodynamic Response to Vertical Whole-body Vibration (수직방향 진동에 대한 인체의 6축 방향 반응특성분석)

  • Jeon, Gyeoung-Jin;Kim, Min-Seok;Ahn, Se-Jin;Jeong, Weui-Bong;Yoo, Wan-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.218-223
    • /
    • 2011
  • Seated human subjects have been exposed to vertical vibration so as to investigate six-axis biodynamic response. Sixteen males were exposed to random vertical vibration in the frequency range(3~40Hz) at one vibration magnitude(0.224m/$s^2$ r.m.s.). Forces were measured in the vertical, fore-and-aft, lateral, roll, pitch and yaw direction on the seat. The median of cross-axis apparent mass magnitude in the fore-and-aft direction could reach up to 20% of the apparent mass magnitude at resonance frequency. And the median of apparent eccentric mass magnitude in the roll direction could reach up to 15% of the apparent eccentric mass magnitude in the pitch direction at resonance frequency. But cross-axis apparent mass in the lateral direction and apparent eccentric mass in the yaw direction showed very small.

  • PDF

A Study on the Branch Composition of an Optimum Polarization Diversity by Considering XPD in Indoor Radio Environments (실내무선 환경에서 XPD를 고려한 최적편파 다이버시티의 브랜치 구성에 관한 연구)

  • 하덕호;이주현;윤영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.302-311
    • /
    • 1999
  • In this paper, in order to suggest an optimal polarization diversity composition method in indoor radio wave propagation environments, the variation of the cross polarization discrimination(XPD) was theoretically analyzed by a computer simulation and compared to the actual measured data. From the results, it can be seen that the cross polarization discrimination of the case, a circularly polarized antenna was used at the transmitting end as well as the vertical and horizontal polarized antenna branches were used at receiving end (CV-CH), is lower than that of the case, horizontal polarized antenna at the transmitting end as well as the horizontal and vertical polarized antenna branches at the receiving end(HH-HV), and that of the case, vertical polarized antenna at the transmitting end as well as the vertical and horizontal polarized antenna branches at the receiving end(VV-VH). In this paper, to get more effective CV-CH polarization diversity composition, the amount of cross polarization discrimination values at the signals received by horizontal polarized antenna is compensated and the polarization diversity effect through the cumulative probability distribution is estimated. From the evaluation results, it was found that the polarization diversity effect was better at the compensated case than at the uncompensated case. On the other hand, it can be known that the polarization diversity effect is getting better as the cross polarization discrimination values are getting lower, and also be known that the effect can be improved if a transmitting antenna is composed of the ellipse polarized antenna by adjusting the axial ratio of the circularly polarized antenna and, a receiving antenna is made up of the vertical and horizontal polarized antenna branches.

  • PDF