• 제목/요약/키워드: 교류 급전시스템

검색결과 40건 처리시간 0.03초

교류 급전시스템 성능검증을 위한 시험방안에 관한 연구 (A Study on tests process for verification of AC Traction system performance)

  • 정호성;이기원;김주락;한문섭;김진희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2202-2203
    • /
    • 2011
  • AC substation of urban transit supplies a suitable AC power on electricity vehicles. AC substation is verified electrical safety of system through pre-operation inspection on electrical installations to be supplied power from KEPCO. However, because test items and method for AC traction system are unprepared on pre-operation inspection, the general safety and performance verification of AC traction system are very insufficient. Therefore this paper analyze the test examples such as factory equipment tests, factory combined tests and railway tests for the safety and performance verification of AC traction system and present a suitable test items and test standard in domestic.

  • PDF

철도차량 운행 및 선로조건에 따른 교류 급전시스템의 안정성 연구 (A study on stability of feeder system considering driving of railway vehicle and rail conditions)

  • 김재문;김양수;이종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2213-2214
    • /
    • 2011
  • It is important to consider power stability in case of design and construction of a substation at railroad because a train is operated by electricity and tains are drived simultaneous at the same section. This paper described stability of feeder system considering driving conditions and railroad conditions of train which is drived. Simulation tool, TOM(Train Operations Model) software is used to ensure stability of feeder system. As results of simulation, feeder voltage source is in limits on driving operation dia of trains.

  • PDF

교류전기철도시스템에서 급전계통 구성에 따른 급전성능 비교검토 (The comparison and investigation of power supply capability according to feeding schemes in AC electric railway system)

  • 이장무;오광해;창상훈;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1236-1238
    • /
    • 2001
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the collection voltage of train and supplying power from railway substation are greatly unlike. For simulation of collection voltage and power supply according to feeding scheme, using 6-port network analysis proposed previously simulate collection voltage and supply power according to feeding scheme(Parallel Post feeding system, normal feeding system and tie feeding system) and compare and investigate each characteristics.

  • PDF

에너지 효율 향상을 위한 직류/교류 하이브리드 급전시스템의 해석 (DC/AC Hybrid Distribution System Analysis for Improving Energy Efficiency)

  • 이영진;한동화;최중묵;반충환;김동진;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.244-245
    • /
    • 2010
  • Hybrid distribution system is able to use existing AC load under AC power and DC power by providing existing AC power and proper DC voltage at the same time. and, the future expected DC appliance is also available. Hybrid distribution system is divided into two different type. the one is DC common method and the other is AC common method. This paper design each system, and study operating characteristics for improving energy efficiency.

  • PDF

교류 급전시스템 보호를 위한 전차선로 고장특성 분석 (Analysis of fault characteristics in Catenary system for protection of AC feeding system)

  • 정호성;박영;김주락;권삼영;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1089-1090
    • /
    • 2006
  • This paper analyzes impedance convergence characteristics and harmonics of electric locomotives operation and fault condition. To simulate the various fault and operation condition, AT feeding system and various locomotives are modeled using PSCAD/EMTDC. Analysis shows that impedance are converged into protection area in the case of short fault between catenary and rail or catenary and feeder line but in the case of disconnection fault, impedance is rater bigger so protective relay can't detect the fault. Therefore more analysis of overload and high impedance fault caused disconnection fault is needed.

  • PDF

교류전기철도 급전시스템의 전차선 전압해석 (Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System)

  • 이승혁;정현수;김진오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.490-496
    • /
    • 2002
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode far locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Finally, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

  • PDF

부하 특성에 따른 교류 급전시스템에서의 보호방식 연구 (A Study on Protection system to the Load Characteristics on the AC Feeder System)

  • 정호성;한문섭;이장무;김주락
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

EMTDC에 의한 교류 전철급전시스템 사고 해석 (Fault Analysis of AC Electric Railway System Mode by EMTDC)

  • 이한민;오광해;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권9호
    • /
    • pp.521-527
    • /
    • 2003
  • This study presents the AC railway system modeled by EMTDC in detail. The ,model made by EMTDC have a lot of advantages. It could be available for the system change, simulated repeatedly and also applied regarding very complicated systems. EMTDC simulations to verify this model are compared with the hand calculations. It is confirmed that the model made by EMTDC is correctly designed.

PSCAD/EMTDC를 이용한 교류 전철급전시스템 해석 (Analysis of AC Electric Railway System using the PSCAD/EMTDC)

  • 이한민;한문섭;창상훈;오광해;이장무;김주락
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1241-1243
    • /
    • 2002
  • This study presents a AC electric railway system analysis using PSCAD/EMTDC for circuit analysis and fault studies. This PSCAD/EMTDC model includes feeder, contact line, rails. Scott-transformer. Auto-transformer and so on. This model is based on four-port network which is an extension of two-port network theory. In order to verify the proposed model, fault studies of a test system are performed.

  • PDF

축소형 교류급전시스템 절연구간 자동절체장치 성능시험 (Test results of small scale changeover system using in neutral section for AC feeding system)

  • 장동욱;한문섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.948-953
    • /
    • 2011
  • In AC railway feeding system, three phase received from the network is changed to two phase power sources with different phases. The main circuit breaker installed train is automatically open by track signal when the train passes the neutral section. In order to continuously supply power source to train, the changeover system was used in Japan. Therefore, the train is able to operate under powering condition when it was passing through the neutral section. We investigated the control method to reduce the inrush current flowing main transformer in train. To examine the inrush current and operate the static semiconductor switch such as thyristor, we manufactured the small scale the changeover system and carried out performance tests.

  • PDF