• Title/Summary/Keyword: 광 신호처리

Search Result 228, Processing Time 0.037 seconds

A Study on the Fabrication of Polarimetric Fiber Optic Current Sensor (편광측정법에 의한 광섬유 전류 센서 제작에 관한 연구)

  • Jang, Nam-Young;Chio, Pyung-Suk;Eun, Jae-Jeong;Park, Hae-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.33-41
    • /
    • 2004
  • In this paper, a polarimetric fiber optic current sensor(P-FOCS) is experimented and fabricated, and then a possibility to the commercial utilization of the P-FOCS is also investigated. The P-FOCS measures an applied current by a Faraday rotation linearly proportional to a magnetic field generated by the applied current. The bending-induced linear birefringence in the sensing fiber is minimized by using the low birefringent fiber. Also, all fiber-optic components are used to avoid optical losses coming from the use of bulk components. A signal processing circuit is constructed and used to eliminate the effects of intensity variations in the output signal due to losses coming from misalignments of components such as fiber connectors. Using the optical source of 632.8nm wavelength, Faraday rotation is measured by passing through the sensing fiber within the solenoid of about 1500 turns which is equivalent to a current source of about 7500A. In the range of 1000A to 7500A, the measurement error for linearity is within about 1.5%.

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Movement Monitoring System for Marine Buoy (해상 브이용 움직임 감시 시스템)

  • Oh, Jin Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.311-317
    • /
    • 2014
  • Buoy has different motion characteristics depends on the sea weather situations. The motion characteristics has an impact on antenna, solar power generation system and etc. installed within a buoy. Therefore, it is important to analyse motion characteristics for management and analyse the buoy conditions. This paper's Buoy motion monitoring system uses gyro sensor to detect motions of a light buoy, and the measured data transfers to the PC on the shore using signal processing algorithm. The aim of this research is to develop monitoring and management mechanism of a buoy by applying motion monitoring system. In this paper, the operation characteristic of movement monitoring system is verified through experiment. Further, in this paper, it can apply such as real-time visibility into the status of the buoy or many ocean facility's motion estimation of the future.

Recent Progress in Multiplexed Detection of Biomarkers Based on Quantum Dots (양자점 기반 다중 바이오마커 검출법의 연구동향)

  • Kim, Yerin;Choi, Yu Rim;Kim, Bong-Geun;Na, Hyon Bin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.451-458
    • /
    • 2022
  • Semiconductor quantum dots (QDs) are optical probes with excellent fluorescence properties. Therefore, they have been applied to various bio-medical imaging techniques and biosensors. Due to the unique optical characteristics of wide absorption and narrow fluorescence energy bands, multiple types of signals can be generated by the combination of fluorescence wavelengths from different QDs, which enables the simultaneous detection of more than two biomarkers. In this review, the advantages and applications of QDs and QD nanobeads (QBs) in multiple biomarker assays were described, and new developments or improvements in multiplexed biomarker detection techniques were summarized. In particular, recent reports were summarized, focusing on the design strategies in immunoassay construction and signal transducing materials for fluorescence-linked immunosorbent assays using QDs and immunochromatographic assays using QBs. New detection platforms will be developed for early diagnosis of diseases and other fields if multiplexed detection technologies of excellent accuracy and sensitivity are combined with artificial intelligence algorithms.

Implementation of FBG Sensor Network System for Monitoring Structure Deformation (구조물 변형 모니터링을 위한 FBG센서 네트워크 시스템 구현)

  • Park, Jang-Sik;Park, Keun-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.8
    • /
    • pp.841-846
    • /
    • 2014
  • FBG sensors are mainly used to measure deformation of structures such as tunnels, bridges and ships. In this paper, an interrogator of FBG sensors is developed and implemented to measure the status of structures. A developed interrogator includes CAN wired and Zigbee wireless communication for remote monitoring. Strain of structure is measured using shift of wavelength of reflected light from FBG sensor. A digital signal controller is used to process signals of a FBG sensor and transmit data for remote monitoring. As a result of experiment, developed interrogator is effective to measure deformation of structures.

Algorithm of Optical Camera Communications Using Rolling-Shutter Effect (롤링셔터 효과를 이용한 광학 카메라통신 알고리즘)

  • Lee, Jungho;Kim, Nayeong;Ju, MinChul;Park, Youngil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.4
    • /
    • pp.454-460
    • /
    • 2016
  • Unlike conventional visible light communications (VLC) adopting photo detectors (PD), optical camera communications (OCC) employs cameras in detecting the transmitted data. Especially, the data rate of OCC can be enhanced by using the principle of rolling-shutter, which is the operating scheme of a CMOS image sensor. In this study, we consider a novel OCC system for high-speed real time video processing to transmit high speed data from LED and to acquire image utilizing rolling-shutter effect of CMOS image sensor. Also, we demonstrate the improved performance of proposed system using a test-bed.

Study of Design for Convertible ROV (새로운 Convertible ROV의 설계 연구)

  • Choi, Hyeung-Sik;Jeon, Ji-Kwang;Jeong, Sang-Ki;Park, Han-Il;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.451-458
    • /
    • 2012
  • In this paper, the design study of a new convertible six d.o.f underwater robot which can be a ROV or AUV according to underwater work purpose is presented. A structure design about the ROV and the AUV and its design on the control system is presented. In case of the AUV, an analysis on thruster forces in accordance with operating speed has been performed. A sensor fusion board which can proceed various sensor signals to identify correct positions and speeds has been developed and a total control system including EKF(Extended Kalman Filter) has been designed and developed.

A Study on the Domestic Fireworks System (불꽃놀이 시스템의 국산화에 대한 연구)

  • Choi, Joon-Kee;Son, Moo-Yeol;Lee, Jong-Kwang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Fireworks are used in our country, most of U.S. equipment and software systems are old and outdated technology. If the Fireworks receives a signal, then the start of the pre-placed as the signal proceeds to the middle of a problem with the site manager directly turn off the power and turn on again. Manager, where it should be handled directly. So, in this paper, we researched a domestically developed technology to escape the reality that relies on foreign technology. Our technology should be suited the convenience, reliability and lower cost. This technology can generate revenue from overseas.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.