• Title/Summary/Keyword: 광학 재료

Search Result 1,518, Processing Time 0.029 seconds

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants (Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구)

  • Kang, Hyun-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The objective of this study was to investigate the effects of calcium phosphate coated titanium implant surface on bone response and implant stability at early stage of healing period of 3 weeks and later healing period of 6 weeks. Material and methods: A total of 24 machined, screw-shaped implants (Dentium Co., Ltd., Seoul, Korea) which dimensions were 3.3 mm in diameter and 5.0 mm in length, were used in this research. All implants (n = 24), made of commercially pure (grade IV) titanium, were divided into 2 groups. Twelve implants (n = 12) were machined without any surface modification (control). The test implants (n = 12) were anodized and coated with thin film (150nm) of calcium phosphate by electron-beam deposition. The implants were placed on the proximal surface of the rabbit tibiae. The bone to implant contact (BIC) ratios was evaluated after 3 and 6 weeks of implant insertion. Results: The BIC percentage of calcium phosphate coated implants ($70.8{\pm}18.9%$) was significantly higher than that of machined implants ($44.1{\pm}16.5%$) 3 weeks after implant insertion (P = 0.0264). However, there was no significant difference between the groups after 6 weeks of healing (P > .05). Conclusion: The histomorphometric evaluation of implant surface revealed that; 1. After 3 weeks early healing period, bone to implant contact (BIC) percentage of calcium phosphate coated implants (70.8%) was much greater than that of surface untreated machined implants (44.1%) with P = 0.0264. 2. After 6 weeks healing period, however, BIC percentage of calcium phosphate coated implants group (79.0%) was similar to the machined only implant group (78.6%). There was no statistical difference between two groups (P = 0.8074). 3. We found the significant deference between the control group and experimental group during the early healing period of 3 weeks. But no statistical difference was found between two groups during the later of 6 weeks.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

The effects of platelet-rich plasma(PRP) in combination with anorganic bovine bone($Bio-Oss^{(R)}$) on the early wound healing of rabbit cranial defects (혈소판 농축 혈장과 혼합된 이종골 이식재($Bio-Oss^{(R)}$)가 가토 두개골 결손부 초기 치유에 미치는 영향)

  • Lim, Dong-Woong;Jang, Hyun-Seon;Park, Ju-Chol;Kim, Heoung-Jung;Lee, Jong-Woo;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.217-234
    • /
    • 2005
  • 혈소판 농축 혈장은 구강과 안면부 재건수술에 새로이 사용되는 유용한 첨가물이다. 혈소판은 상처 치유과정에서 매우 중요하며, 혈소판은 상처부위에 빠르게 도달하여 응고를 형성한다. 그리고 다양한 성장인자를 분비한다. 이러한 성장인자는 골의 형성과 혈관의 증가, 골 이식재의 치유에 관여하는 것으로 생각된다. 본 연구의 목적은 실험 동물을 통하여 혈소판 농축 혈장에 함유된 혈소판의 정량화를 통한 성장인자 함유량을 추정하고, 방사선학적, 조직학적 평가를 통해 혈소판 농축 혈장이 초기의 골형성에 미치는 영향에 대한 평가를 하는데 있다. 15마리의 가토 두개골에 6mm trephine bur(외경 8mm)를 이용하여 경뇌막의 손상을 주지 않도록 하면서 4개의 결손부를 형성하였다. 각각의 두개골 결손부는 $Bio-Oss^{(R)}$만 이식한 군, PRP만 이식한 군, PRP와 $Bio-Oss^{(R)}$를 혼합하여 이식한군, 그리고 아무것도 이식하지 않은 군을 대조군으로 설정하였다. 각각의 재료를 이식한 후 비흡수성 차폐막($Tefgen^{(R)}$)을 위치시키고 흡수성 봉합사로 일차봉합을 시행하였다. 각 군 당 술 후 1, 2, 4주의 치유기간을 설정하였다. 동물을 희생시키고 두개골을 절제하였다. 먼저 방사선학적인 골 밀도 측정을 시행하고, 조직학적 평가를 위해 통법에 따라 조직 표본을 제작한 후 광학현미경으로 관찰하였다. 또한 가토 귀 변연정맥에서 채취한 10 ml의 혈액을 원심분리하여 혈소판 함유량을 평가하여 다음과 같은 결과를 얻었다. 1. 혈소판 농축 혈장은 일반 혈액에 비해 약 4.02배 많은 수의 혈소판이 함유되어 있었다. 2. 방사선적인 평가에서 1, 2, 4주 사이에 대조군과 비교하여 $Bio-Oss^{(R)}$에 PRP를 이식한 군에서 골의 밀도는 큰 차이를 보이고 있다(p<0.01). 하지만, 동일한 시기에 PRP만 이식한 군과 대조군의 차이는 발견할 수 없었으며 (p>0.05), $Bio-Oss^{(R)}$만 이식한 군과 $Bio-Oss^{(R)}$에 PRP를 이식한 군의 차이 또한 발견할 수 없었다(p>0.05). 3. 조직학적 평가에서 모든 이식재는 시간이 경과할수록 골 형성이 증가함을 알 수 있었다. 대조군에 비해 PRP만 이식한 군에서 더 두꺼운 섬유성 결합을 보이고 있다. 대조군과 PRP만 이식한 군과 비교해 $Bio-Oss^{(R)}$$Bio-Oss^{(R)}$에 PRP를 혼합 이식한 군에서 골의 형성이 더 진행됨을 알 수 있었다. $Bio-Oss^{(R)}$에 PRP를 혼합 이식한 군이 $Bio-Oss^{(R)}$만 이식한 군에서보다 더 많은 신생골 형성을 관찰할 수 있다. 이상의 결과에서 가토의 두개골 결손부에 $Bio-Oss^{(R)}$에 PRP를 혼합 이식하였을 경우 결손부의 초기 골 형성을 촉진 할 수 있음을 시사하였다.

The effect of enamel matrix derivative (EMD) in combination with deproteinized bovine bone material (DBBM) on the early wound healing of rabbit calvarial defects (법랑기질 단백질 유도체와 혼합된 이종골 이식재가 토끼 두개골 결손부 초기 치유에 미치는 영향)

  • Kim, You-Seok;Jang, Hyun-Seon;Park, Ju-Chol;Kim, Heoung-Jung;Lee, Jong-Woo;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.199-216
    • /
    • 2005
  • 치주치료의 가장 중요한 목적은 상실된 치주조직의 형태적, 기능적 재건이다. 법랑기칠 단백질 유도체(enamel matrix derivative: EMD)는 치주 병소에 사용시 상피세포의 증식을 억제하며 치주인대 및 백악아세포를 활성화시켜 무세포성 백악질 및 치주인대와 골조직의 생성을 유도한다고 보고되고 있다. 또한 법랑기질 단백칠 유도체는 골모세포의 증식 및 분화를 촉진시키며 alkaline phosphatase의 활성 및 mineralized nodule의 형성을 촉진시킨다고 보고되고 있다. 이에 본 연구에서는 토끼 두개골 결손부에 법랑기질 단백질 유도체와 이종골 이식재를 이식한 후 골밀도를 방사선학적으로 분석하고, 신생골 형성 및 주변 조직 반응을 조직학적으로 관찰, 평가하고자 하였다. 토끼 두개골에 6mm trephine bur(외경 8mm)를 이용하여 경뇌막에 손상을 주지 않도록 하면서 4개의 결손부를 형성하였다. 아무것도 이식하지 않은 군을 음성 대조군으로, 이종골 이식재 ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland)을 이식한 군을 양성 대조군으로 설정하였다. 법랑기질 단백질 유도체 ($Emdogain^{(R)}$, Biora, Inc., Sweden)만 이식한 군과 법랑기질 단백질 유도체와 이종골 이식재를 혼합하여 이식한 군을 설험군으로 설정하였다. 각각의 재료를 이식한 후 비흡수성 차폐막 ($Tefgen^{(R)}$, Lifecore Biomedical, Inc., U.S.A.)을 위치시키고 흡수성 봉합사로 일차봉합을 시행하였다. 각 군당 술 후 1, 2, 4주의 치유기간을 설정하였다. 동물을 희생시킨 후 두개골을 절제하여 먼저 방사선학적인 골밀도측정을 시행한 후 10% formalin에 고정한 후 통법에 따라 조직표본을 제작하여 광학현미경으로 관찰하였다. 1. 방사선학적인 평가에서 1, 2, 4주에 대조군과 법랑기질 단백질 유도체만 이식한 군과 비교해 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군에서 더 큰 골의 밀도를 보이고 있었다 (P<0.01). 하지만, 동일한 시기에 대조군과 법랑기질 단백질 유도체만 이식한 군과의 차이는 발견할 수 없었으며 (P>0.05), 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군의 차이 또한 발견할 수 없었다 (P>0.05). 2. 조직학적인 평가에서 1, 2, 4주에 대조군과 법랑기질 단백질 유도체만 이식한 군과 비교해 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한군에서 골의 형성이 더 진행됨을 알 수 있었다. 법랑기질 단백질 유도체만 이식한 군이 대조군보다 2주에서 더 많은 신생골을 볼 수 있었으며, 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군이 이종골 이식재만 이식한 군보다 1, 2주에서 더 많은 신생골을 관찰할 수 있었다. 이상의 결과에서 법랑기질 단백질 유도체는 토끼 두개골 결손부 치유단계에서 초기 골 형성을 촉진하는 것으로 사료되며 골 이식시에 법랑기질 단백질 유도체를 적용하는 것은 유용한 술식으로 사료된다.

Histomorphologic Change of Radiation Pneumonitis in Rat Lungs : Captopril Reduces Rat Lung Injury Induced by Irradiation (X-선 조사로 생긴 흰쥐 폐장 상해의 형태학적 변화: Captopril에 의한 폐장 상해의 경감 효과)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.238-248
    • /
    • 1999
  • Purpose : To assess the histomorphologic changes in the rat lung injury induced by radiation, to determine whether captopril reduces the rat lung injury and to evaluate change in TNF-${\alpha}$ and TGF-${\beta}$ in rat lung damage by radiation and captopril Methods and material : Right lungs in male Sprague-Dawley rats were divided irradiation alone (10, 20, 30 Gy) or radiation (same dose with radiation alone group) with captopril (500 mg/L). Radiation alone group were sacrificed at twelve hours and eleven weeks after radiation and radiation with captopril group (captopril group) were sacrificed at eleven weeks after radiation with captopril. We examined the light microscope and electron microscopic features in the groups. Results : In radiation alone group, there were patch parenchymal collapse and consolidation at twelve hours after radiation. The increase of radiation dose shows more prominent the severity and broader the affected areas. Eleven weeks after radiation, the severity and areas of fibrosis had increased in proportion to radiation dose given in the radiation alone group. There was notable decrease of lung fibrosis in captopril group than in radiation alone group. The number of mast cells rapidly increased with increase of radiation dose in radiation alone group and the degree of increase of mast cell number and severity of collagen accumulation more decreased in captopril group than in radiation alone group. In radiation alone group, expression of TNF-${\alpha}$ and TGF-${\beta}$ increased according to increase of radiation dose at twelve hours after radiation in both group. At eleven weeks after radiation, expression of TGF-${\beta}$ increased according to increase of radiation dose in radiation group but somewhat decreased in captopril group. In the captopril group the collagen deposition increased but less dense than those of radiation alone group. The severity of perivascular thickening, capillary change, the number and degranulation of mast cells more decreased in the captopril group than in the radiation alone group. Conclusion : It is concluded that the effect of captopril in the rat lungs after radiation was considered to be due to its effect on inhibition of mast cells and reduction of collagen deposition, and captopril may be protect in lung damage after radiation. We observed expression of TNF-${\alpha}$ and TGF-${\beta}$ increased at the early phase after radiation and expression of TGF-${\beta}$ increased in proportion to increase of radiation dose at the chronic phase after radiation. This results will contribute to future investigation in reduction mechanism of captopril in lung damage after radiation.

  • PDF

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

Effect of platelet-rich plasma on bone regeneration in ovariectomized osteoporotic rats (골다공증 유발 쥐에서 혈소판 농축 혈장이 골 재생에 미치는 영향)

  • Cho, Jong-Moon;Kang, Jeong-Kyung;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.16-27
    • /
    • 2010
  • Purpose: The aim of this experimental study is to observe the effect of platelet-rich plasma (PRP) on early bone regeneration of rats both in normal condition and in osteoporosis induced by ovariectomy. Material and methods: Total 40 Sprague-Dawley female rats were divided into 4 groups. A 8-mm-diameter calvarial critical-sized defect (CSD) was made by drilling with trephine at the center of calvaria in cranium of every rat. Every CSD was augmented with an osteoconductive synthetic alloplastic substitute ($MBCP^{TM}$) and PRP as follows. Group A; 10 non-ovariectomized rats grafted with only $MBCP^{TM}$. Group B; 10 non-ovariectomized rats grafted with $MBCP^{TM}$ and PRP. Group C; 10 ovariectomized rats grafted with only $MBCP^{TM}$. Group D; 10 ovariectomized rats grafted with $MBCP^{TM}$ and PRP. At 4 weeks after graft, every rat was sacrificed. And histomorphometric analysis was performed by measuring calcified area of new bone formation within the CSD. Results: Comparing four groups, results were obtained as follows. 1. In non-ovariectomized groups, PRP showed a positive effect somewhat but not significant (P > .05). 2. In ovariectomized groups, PRP showed a positive effect significantly (P < .05). 3. In PRP untreated groups, ovariectomy diminished bone regeneration significantly (P < .05). 4. In PRP treated groups, ovariectomy diminished bone regeneration somewhat but not significant (P > .05). Conclusion: Within the limitation of this study, it can be concluded that PRP in combination with an osteoconductive synthetic alloplastic substitute has an effect on bone regeneration more significantly in ovariectomized osteoporotic rats than in normal rats.

Marginal fidelity of zirconia core using MAD/MAM system (MAD/MAM을 이용한 치과용 지르코니아 코어의 변연 적합도)

  • Kang, Dong-Rim;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the fit of zirconia core using MAD/MAM system comparing to that of conventional metal-ceramic and CAD/CAM system. Materials and methods: Duplicating the prepared resin tooth, 50 improved stone dies were fabricated. These dies are classified as a group of 5 to create the core. The groups were composed of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Rainbow^{TM}$, and $Zirkonzhan^{(R)}$. Each core was cemented to stone die, and then, absolute marginal discrepancy was measured with microscope at a magnification of ${\times}50$. Statistical analysis was done with one-way ANOVA test and Tukey's HSD test. Results: The mean absolute marginal discrepancy for metal-ceramic was $51.97{\pm}23.38{\mu}m$, for $Cercon^{(R)}$ was $62.16{\pm}25.88{\mu}m$, for $Ceramill^{(R)}$ was $67.64{\pm}40.38{\mu}m$, for $Rainbow^{TM}$ was $125.07{\pm}42.19{\mu}m$, and for $Zirkonzhan^{(R)}$ was $105{\pm}44.61{\mu}m$. Conclusion: 1. Fit of margin was identified as in the order of metal-ceramic, $Cercon^{(R)}$, $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 2. Absolute marginal discrepancy of the zirconia core that designed by MAD/MAM system had significant differences in order of $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, and $Rainbow^{TM}$. 3. The mean absolute marginal discrepancy between $Cercon^{(R)}$ and $Ceramill^{(R)}$ did not show significant differences.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.