• 제목/요약/키워드: 광자

Search Result 1,321, Processing Time 0.032 seconds

The Analyses of Treatment Results and Prognostic Factors in Supradiaphragmatic CS I-II Hodgkin's Disease (횡경막상부에 국한된 임상적 병기 1-2기 호지킨병에서 치료 결과와 예후 인자의 분석)

  • Park Won;Suh Chang Ok;Chung Eun Ji;Cho Jae Ho;Chung Hyun Cheol;Kim Joo Hang;Roh Jae Kyung;Hahn Jee Sook;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 1998
  • Purpose : The aim of this retrospective study is to assess the necessity of s1aging laparotomy in the management of supradiaphragmatic CS I-II Hodgkin's disease. Prognostic factors and the usefulness of prognostic factor groups were also analyzed. Materials and Methods : From 1985 to 1995, fifty one Patients who were diagnosed as supradiaphragmatic CS I-II Hodgkin's disease at Yonsei Cancer Center in Seoul, Korea were enrolled in this study Age range was 4 to 67 with median age of 30. The number of patients with each CS IA, II A, and IIB were 16, 25, and 10, respectively. Radiotherapy(RT) was delivered using 4 or 6 MV photon beam to a total dose of 19.5 to 55.6Gy (median dose : 45Gy) with a 1.5 to 1.BGy per fraction. Chemotherapy(CT) was given in 2-12 cycles(median : 6 cycles). Thirty one Patients were treated with RT alone, 4 patients with CT alone and 16 patients with combined chemoradiotherapy. RT volumes varied from involved fields(3), subtotal nodal fields(18) or mantle fields(26). Results : Five-year disease-free survival rate(DFS) was $78.0\%$ and overall survival rate(05) was $87.6\%$. Fifty Patients achieved a complete remission after initial treatment and 8 patients were relapsed. Salvage therapy was given to 7 patients, 1 with RT alone, 4 with CT alone, 2 with RT+CT. Only two patients were successfully salvaged. Feminine gender and large media-stinal adenopathy were significant adverse prognostic factors in the univariate analysis for DFS. The significant adverse prognostic factors of OS were B symptom and clinical stage. When patients were analyzed according to European Organization for Research and Treatment of Cancer(EORTC) prognostic factor groups, the DFS in Patients with very favorable, favorable and unfavorable group was 100, 100 and $55.8\%$(p<0.05), and the 05 in each patients' group was 100, 100 and $75.1\%$(p<0.05), respectively. In very favorable and favorable groups, the DFS and 05 were all $100\%$ by RT alone, but in unfavorable group, RT with CT had a lesser relapse rate than RT alone. The subtotal nodal irradiation had better OFS than mantle RT in patients treated with RT. Conclusion : In present study, the DFS and OS in patients who did not undergo s1aging laparotomy were similar with the results in the literatures of which patients were surgically staged. Therefore, we may suggest that staging laparotomy would not influence the outcome of treatments. In univariate analysis, gender, large mediastinal adenopathy. B symptoms and clinical stage were significant prognostic factors for the survival rate. We confirm the usefulness of EORTC prognostic factor groups which may be a good.

  • PDF

Bladder Preserving Treatment in Patients with Muscle Invasive Bladder Cancer (근침윤성 방광암 환자의 방광 보존적 치료 결과)

  • Yu, Jeong-Il;Oh, Dong-Ryol;Huh, Seung-Jae;Choi, Han-Yong;Lee, Hyon-Moo;Jeon, Seong-Soo;Yim, Ho-Young;Kim, Won-Suk;Lim, Do-Hoon;Ahn, Yong-Chan;Park, Won
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.70-78
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study analyzed the tumor response, overall survival, progression free survival and related prognostic factors in patients with muscle invasive bladder cancer subjected to bladder preserving treatment. $\underline{Materials\;and\;Methods}$: Between August 1995 and June 2004, 37 patients with muscle invasive (transitional cell carcinoma, clinically stage T2-4) bladder cancer were enrolled for the treatment protocol of bladder preservation. There were 33 males and 4 females, and the median age was 67 years (range $38{\sim}86\;years$). Transurethral resection of the bladder (TURB) was performed in 17 patients who underwent complete resection. The median radiation dose administered was 64.8 Gy (range $55.8{\sim}67\;Gy$). The survival rate was calculated by the Kaplan-Meier method. $\underline{Results}$: An evaluation of the response rate was determined by abdomen-pelvic CT and cystoscopy at three months after radiotherapy. A complete response was seen in 17 patients (46%). The survival rate at three years was 54.7%, with 54 months of median survival (range $3{\sim}91$ months). During the study, 17 patients died and 13 patients had died from bladder cancer. The progression free survival rate at three years was 37.2%. There were 24 patients (64.9%) who had disease recurrence: 16 patients (43.2%) had local recurrence, 6 patients (16.2%) had a distant recurrence, and 2 patients (5.4%) had both a local and distant recurrence. The survival rate (p=0.0009) and progression free survival rates (p=0.001) were statistically significant when compared to the response rate after radiotherapy. $\underline{Conclusion}$: The availability of complete TURB and appropriate chemoradiotherapy were important predictors for bladder preservation and survival.

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

Studies on the Applications of PSL, TL and ESR Methods for The Detection of Irradiated Foods not Allowed to be Irradiated in Korea (광자극발광법, 열발광법 및 전자스핀공명법을 이용한 국내 방사선 조사 허용 외 식품에 대한 검지법 적용 연구)

  • Kim, Kyu-Heon;Choi, Eun-Jin;Chang, Ho-Won;Shin, Choon-Shik;Kim, Moon-Young;Hwang, Cho-Rong;Kim, Eun-Jeong;Jo, Tae-Yong;Park, Geon-Sang;Kang, Myung-Hee;Kim, Jae-I;Kim, Jin-Sook;Park, Sue-Nie;Seong, Rack-Seon;Jang, Young-Mi;Yoon, Hae-Sung;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.233-246
    • /
    • 2012
  • In this study, we investigated the applicability of the photostimulated luminescence(PSL), thermoluminescence(TL) and electron spin resonance(ESR) methods for various foods which are not allowed to be irradiated in Korea. All 15 foods including sesame, almond, peanut, cocoa powder etc. were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative(lower than 700). The photon counts irradiated(1 kGy) dried shrimp, roasted peanut and seasoned peanut showed positive(higher than 5,000) and the other samples were negative or intermediate(> 700 and < 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal(single-line) intensity of irradiated foods was higher than non-irradiated foods. In particular, the specific ESR signals of irradiation-induced crystalline sugar, cellulose and bone radical were detected in dried plum, raisin, dried cherry, mango(dried, frozen), rambutan, cocoa(powder), cinnamon, parsley, carrot, broccoli, dried arrow squid, dried pollack and dried shrimp. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods because TL method is not able to detect the irradiated foods rarely composed of minerals. ESR is also a difficult method to detect the changes of ESR signal patterns of food. It is concluded that TL analysis or ESR assay is suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

The Role of Primary Radiotherapy for Squamous Cell Carcinoma of the Suprag1ottic Larynx (성문상부 상피세포암에서의 근치적 방사선치료의 역할)

  • Kim, Won-Taek;Kim, Dong-Won;Kwon, Byung-Hyun;Nam, Ji-Ho;Hur, Won-Joo
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.233-243
    • /
    • 2000
  • Purpose : First of all, this study was performed to assess the result of curative radiotherapy and to evaluate different possible prognostic factors for squamous cell carcinoma of the supraglottic larynx treated at the Pusan National University Hospital. The second goal of this study was by comparing our data with those of other study groups, to determine the better treatment policy of supraglottic cancer in future. Methods and Material : Thirty-two patients with squamous cell carcinoma of the supraglottic larynx were treated with radiotherapy at Pusan National University Hospital, from August 1985 to December 1996. Minimum follow-up period was 29 months, Twenty-seven patients (84.4$\%$) were followed up over 5 years. Radiotherapy was delivered with 6 MV photons to the primary laryngeal tumor and regional iymphatics with shrinking field technique. Ail patients received radiotherapy under conventional fractionated schedule (once a day). Median total tumor dose was 70.2 Gy (range, 55.8 to 75.6 Gy) on primary or gross tumor lesion. Thirteen patients had Induction chemotherapy with cisplatln and 5-fluorouracil (1-3 cycles). Patient distribution, according to the different stages, were as follows: stage I, 5/32 (15.6$\%$): stage II, 10/32 (31.3$\%$); stage III, 8/32 (25$\%$): stage IV, 9/32 (28.1$\%$). Results :The 5-year overall survival rate of the whole series (32 patients) was 51.7$\%$. The overall survival rate at 5-years was 80$\%$ in stage I, 66.7$\%$ in stage II, 42.9$\%$ in stage III, 25$\%$ in stage IV (p=0.0958). The S-year local control rates after radiotherapy were as fellows: stage I, 100$\%$; stage II, 60$\%$ stage III, 62.5$\%$; stage IV, 44.4$\%$ (p=0.233). Overall vocal preservation rates was 65.6$\%$, 100% In stage I, 70% in stage II, 62.5$\%$ In stage III, 44.4$\%$ in stage IV (p=0.210). There was no statistical significance in survival and local control rate between neoadjuvant chemotherapy followed by radiotherapy group and radiotherapy alone group. Severe laryngeal edema was found in 2 cases after radiotllerapy, emergent tracheostomy was done. Four patients were died from distant metastsis, . three in lung, one in brain. Double primary tumor was found in 2 cases, one in lung (metachronous), another in thyroid (synchronous). Ulcerative lesions were revealed as unfavorable prognostic factor ( p=0.0215), and radiation dose (more or less than 70.2 Gy) was an important factor on survival (p=0.002). Conclusion : The role of radiotherapy treatment of supraglottic carcinoma is to important factor on survival and to preserve the laryngeal function. Based on our data and other studies, early and moderately advanced supragiottic carcinomas could be successfully treated with either consewative surgery or radiotherapy alone. Both modalities showed similar results in survival and vocal preservation. For the advanced cases, radiotherapy alone is Inadequate for curative aim and surgery combined with radiotherapy should be done in operable patients. When patients refuse operation or want to preserve vocal function, or for the patients with inoperable medical conditions, combined chemoradiotherapy (concurrent) or altered fractionated radiotherapy with or without radiosensitizer should be taken into consideration in future.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF