• Title/Summary/Keyword: 광대역신호

Search Result 673, Processing Time 0.028 seconds

Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment (세포 실험용 다중 주파수 동시 노출 장치 제작)

  • Kim, Tae-Hong;Seo, Min-Gyeong;Mun, Ji-Yeon;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.213-219
    • /
    • 2012
  • Recently, we are simultaneously exposed by various electromagnetic sources due to an increase of mobile communication services. However, EMF(Electric, Magnetic and Electromagnetic Field) study has been performed mainly about only single frequency. The objective of this paper is to develop an multiple-frequency exposure system for in vitro experiment. The exposure unit for in vitro experiments was designed by radial transmission line type to get broadband characteristics to generate signals of CDMA at 836.5 MHz and WCDMA at 1950 MHz frequency simultaneously. The modulated signals were delivered to the conical antenna through amplifier, digital attenuator and RF combiner. SAR values were obtained by the averaged values of 3 measured values at 9 points in petri dish using the fiber optic temperature probe. The measured return loss was under -15 dB. For 1 W input power, the mean value and standard deviation of SAR were $0.105{\pm}0.019$ for the CDMA frequency and $0.262{\pm}0.055$ for the WCDMA frequency.

A Dual-Channel 6b 1GS/s 0.18um CMOS ADC for Ultra Wide-Band Communication Systems (초광대역 통신시스템 응용을 위한 이중채널 6b 1GS/s 0.18um CMOS ADC)

  • Cho, Young-Jae;Yoo, Si-Wook;Kim, Young-Lok;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.47-54
    • /
    • 2006
  • This work proposes a dual-channel 6b 1GS/s ADC for ultra wide-band communication system applications. The proposed ADC based on a 6b interpolated flash architecture employs wide-band open-loop track-and-hold amplifiers, comparators with a wide-range differential difference pre-amplifier, latches with reduced kickback noise, on-chip CMOS references, and digital bubble-code correction circuits to optimize power, chip area, and accuracy at 1GS/s. The ADC implemented in a 0.18um 1P6M CMOS technology shows a signal-to-noise-and-distortion ratio of 30dB and a spurious-free dynamic range of 39dB at 1GS/s. The measured differential and integral non-linearities of the prototype ADC are within 1.0LSB and 1.3LSB, respectively. The dual-channel ADC has an active area of $4.0mm^2$ and consumes 594mW at 1GS/s and 1.8V.

Size-Reduced Ring-Hybrid Coupler Using Phase-Inverting Ultra-Wideband Transitions and Its Frequency Doubler Application (초광대역 위상 역전 전이 구조를 이용한 소형화된 링 하이브리드 결합기 및 주파수 체배기 응용)

  • Song, Sun-Young;Kim, Young-Gon;Park, Jin-Hyun;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.1037-1044
    • /
    • 2010
  • In this paper, a new size-reduced, wideband ring-hybrid coupler is presented, and a design of a planar single-balanced doubler using the ring-hybrid is shown. This ring-hybrid coupler employs a pair of ultra-wideband transitions for phase inversion, which consists of in-phase and out of-phase transitions providing a good amplitude and phase balances for wide frequency ranges. The implemented ring-hybrid is 65 % smaller than conventional ring-hybrids, and provides 92.5 % and 81.3 % bandwidth at $\sum$ and $\Delta$ ports, respectively. Thanks to good amplitude and phase balances over wide bandwidth, the ring-hybrid can be applied to implement various balanced components. The implemented single-balanced doubler utilizing the ring-hybrid exhibits typical conversion loss of 10.5 dB for the output frequency range of 4~12 GHz with fundamental suppression level of 30 dB. The performance was also well-predicted with the nonlinear circuit simulation.

Study on Development of HDD Integrity Verification System using FirmOS (FirmOS를 이용한 HDD 무결성 검사 시스템 개발에 관한 연구)

  • Yeom, Jae-Hwan;Oh, Se-Jin;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung;Shin, Jae-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.2
    • /
    • pp.55-61
    • /
    • 2017
  • In radio astronomy, high-capacity HDDs are being used to save huge amounts of HDDs in order to record the observational data. For VLBI observations, observational speeds increase and huge amounts of observational data must be stored as they expand to broadband. As the HDD is frequently used, the number of failures occurred, and then it takes a lot of time to recover it. In addition, if a failed HDD is continuously used, observational data loss occurs. And it costs a lot of money to buy a new HDD. In this study, we developed the integrity verification system of the Serial ATA HDD using FirmOS. The FirmOS is an OS that has been developed to function exclusively for specific purposes on a system having a general server board and CPU. The developed system performs the process of writing and reading specific patterns of data in a physical area of the SATA HDD based on a FirmOS. In addition, we introduced a method to investigate the integrity of HDD integrity by comparing it with the stored pattern data from the HDD controller. Using the developed system, it was easy to determine whether the disk pack used in VLBI observations has error or not, and it is very useful to improve the observation efficiency. This paper introduces the detail for the design, configuration, testing, etc. of the SATA HDD integrity verification system developed.

  • PDF

A Study on the Digital Filter Design using Software for Analysis of Observation Data in Radio Astronomy (전파천문 관측데이터 분석을 위해 소프트웨어를 이용한 디지털필터 설계에 관한 연구)

  • Yeom, Jae-Hwan;Oh, Se-Jin;Roh, Duk-Gyoo;Oh, Chung-Sik;Jung, Dong-Kyu;Shin, Jae-Sik;Kim, Hyo-Ryoung;Hwang, Ju-Yeon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, we propose a design method for a digital filter using software in order to analyze the radio astronomy observation data. Recently the analysis method for radio astronomy observing system is transferring from hardware to software by developing of state-of-the-art of computer system. The existing hardware system is not able to easily change the specification because it is implemented to meet special requirements and it takes a high cost and time. In case of software, however, it has an advantage to implement with small cost if open software is used, and flexibly changes to satisfy the desired specification. But, in order to analyze the massive data like radio astronomy with software, the good performance system is needed for computer. Therefore, this paper proposes a digital filter design method using software with the same performance as that of digital filter implemented with hardware in observation system which is operated by the KVN(Korean VLBI Network). To design a digital filter, the proposed method is performed with standard C language and the simulation is conducted with GNU(GNU's Not Unix) Octave and investigated to show its effectiveness. In addition, for the high speed operation of the designed digital filter, the SSE(Streaming SIMD Extensions) library is adopted for available parallel operation. By the proposed digital filter, the digital filtering is performed for the wide band observation data in the KVN observation mode, the filtering result of narrow band observation has no ripple inside of stop band, and confirmed the effectiveness of the proposed method.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

MIMIC 94 GHz high isolation single balanced cascode mixer (94 GHz 대역의 높은 격리 특성의 MIMIC single balanced cascode 믹서)

  • Lee, Sang-Jin;An, Dan;Lee, Mun-Kyo;Moon, Sung-Woon;Bang, Suk-Ho;Baek, Tae-Jong;Kwon, Hyuk-Ja;Jun, Byoung-Chul;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.9
    • /
    • pp.25-33
    • /
    • 2007
  • In this paper, the high isolation and wideband 94 GHz MIMIC(Millimeter-wave Monolithic Integrated Circuit) single balanced cascode mixer was designed and fabricated. Also, we designed and fabricated a 3 dB tandem coupler which has a high isolation and wideband characteristic. The single balanced resistive mixer which does not require an external IF balun was designed using the 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs metamorphic HEMT(High Electron Mobility Transistor). The DC characteristics of MHEMT's are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency($f_T$) is 189 GHz and the maximum oscillation frequency($f_{max}$) is 334 GHz. A 94 GHz single balanced cascode mixer was fabricated using our 0.1 ${\mu}m$ MHEMT MIMIC process. From the measurements, the fabricated couplers showed wideband characteristics. The conversion loss of single balanced cascode mixer was 9.8 dB at an LO power of 10.9 dBm. The LO to RF isolation of single balanced cascode mixer was 29.5 dB at 94 GHz. We obtained in this study a higher LO-RF isolation compared to some other single balanced mixers.

A Novel Idle Mode Operation in IEEE 802.11 WLANs: Prototype Implementation and Performance Evaluation (IEEE 802.11 WLAN을 위한 Idle Mode Operation: Prototype 구현 및 성능 측정)

  • Jin, Sung-Geun;Han, Kwang-Hun;Choi, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2A
    • /
    • pp.152-161
    • /
    • 2007
  • IEEE 802.11 Wireless Local Area Network (WLAN) became a prevailing technology for the broadband wireless Internet access, and new applications such as Voice over WLAM (VoWLAN) are fast emerging today. For the battery-powered VoWLAN devices, the standby time extension is a key concern for the market acceptance while today's 802.11 is not optimized for such an operation. In this paper, we propose a novel Idle Mode operation, which comprises paging, idle handoff, and delayed handoff. Under the idle mode operation, a Mobile Host (MH) does not need to perform a handoff within a predefined Paging Area (PA). Only when the MH enters a new PA, an idle handoff is performed with a minimum level of signaling. Due to the absence of such an idle mode operation, both IP paging and Power Saving Mode (PSM) have been considered the alternatives so far even though they are not efficient approaches. We implement our proposed scheme in order to prove the feasibility. The implemented prototype demonstrates that the proposed scheme outperforms the legacy alternatives with respect to energy consumption, thus extending the standby time.

Dependencies of Group Velocity and Attenuation Coefficient on Structural Properties in Copper and Nickel Foams with an Open-Celled Structure as Trabecular-Bone-Mimicking Phantoms (해면질골 팬텀으로서 개포된 구조를 갖는 구리폼 및 니켈폼에서 구조적 특성에 대한 군속도 및 감쇠계수의 의존성)

  • Kim, Seong-Il;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.158-166
    • /
    • 2011
  • In the present study, copper and nickel foams with an open-celled structure as trabecular-bone-mimicking phantoms were used to investigate the dependencies of group velocity and attenuation coefficient on structural properties such as trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) in trabecular bone. The group velocity and attenuation coefficient of the copper and nickel foams were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. The separation of the Biot's fast and slow waves was consistently observed in the ultrasonic signals transmitted through the copper and nickel foams. The group velocities of the copper and nickel foams showed highly positive correlations with Tb.Th and Tb.Sp. The attenuation coefficient of the copper foam showed a highly negative correlation with Tb.Th and Tb.Sp, whereas that of the nickle foam showed a highly positive correlation with Tb.Th and Tb.Sp. These results advance our understanding of those previously reported by other researchers using trabecular bone samples or phantoms.

Analysis and Design of High Efficiency Feedforward Amplifier Using Distributed Element Negative Group Delay Circuit (분산 소자 형태의 마이너스 군지연 회로를 이용한 고효율 피드포워드 증폭기의 분석 및 설계)

  • Choi, Heung-Jae;Kim, Young-Gyu;Shim, Sung-Un;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.681-689
    • /
    • 2010
  • We will demonstrate a novel topology for the feedforward amplifier. This amplifier does not use a delay element thus providing an efficiency enhancement and a size reduction by employing a distributed element negative group delay circuit. The insertion loss of the delay element in the conventional feedforward amplifier seriously degrades the efficiency. Usually, a high power co-axial cable or a delay line filter is utilized for a low loss, but the insertion loss, cost and size of the delay element still acts as a bottleneck. The proposed negative group delay circuit removes the necessity of the delay element required for a broadband signal suppression loop. With the fabricated 2-stage distributed element negative group delay circuit with -9 ns of total group delay, a 0.2 dB of insertion loss, and a 30 MHz of bandwidth for a wideband code division multiple access downlink band, the feedforward amplifier with the proposed topology experimentally achieved a 19.4 % power added efficiency and a -53.2 dBc adjacent channel leakage ratio with a 44 dBm average output power.