• Title/Summary/Keyword: 관통균열

Search Result 149, Processing Time 0.034 seconds

New Engineering Estimation Method of J-Integral and COD for Circumferential Through-Wall Cracked Pipes (원주방향 관통균열이 존재하는 배관의 J-적분 및 COD 계산을 위한 새로운 공학적 계산식)

  • Kim, Yun-Jae;Heo, Nam-Su;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.548-553
    • /
    • 2001
  • A new method to estimate the elastic-plastic J-integral and the crack tip opening displacement (COD) for circumferential through-wall cracked pipes under tension and under bending is proposed for Leak-Before-Break (LBB) analysis. Being based on the reference stress method with further modifications, the proposed method is simple to use and easy to be generalised in practice. Comparison of the CODs, predicted using the proposed method with published pipe test data show overall excellent agreement.

Crack Growth Behavior of Tensile Overload for Small Load Amplitude (하중진폭이 작은 인장과대 하중의 균열성장 거동)

  • 유헌일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.2
    • /
    • pp.54-61
    • /
    • 1998
  • This paper examines the crack growth behavior of 7075-T651 aluminum alloy for small tensile overload under high-low block loading condition. The cantilever beam type specimen with a chevron notch is used in this study. The crack growth and closure are investigated by compliance method. The applied initial stress ratios are R=-0.5 R=0.0 and R=0.25 Crack length, effective stress intensity factor range, ratio of effective stress intensity factor range and crack growth rate etc, are inspected with fracture mechanics estimate.

  • PDF

Acoustic emission during fatigue crack penetration behavior of surface cracked plate (표면균열재의 피로균열 관통거동에 따른 어코스틱에미션)

  • 남기우;김선진;오세규;이건찬;오정환;이주석
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.29-38
    • /
    • 1997
  • Crack penetration behavior by fatigue crack propagation and measurements of AE before-and-after crack penetration were examined using SS41 steel plate. Experimental crack shape of SU type was in good agreement with calculated shape rather than S type. Crack propagation behavior on the front surface appears not to change markedly after penetration. However, crack growth on the back surface appears to accelerate as reported by author. As a crack propagates, AE occurred heavily just before penetration. Then, it decreases and crack is penetrating. A transition from plane strain to plane stress was observed by fractographic study. At this time, separation of fracture surface was shown which affects AE occurrence.

  • PDF

Evaluation Model for Restraint Effect of Pressure Induced Bending on the Circumferential Through-Wall Crack Opening Considering Plastic Behavior (소성거동을 고려한 원주방향 관통균열 열림에 미치는 압력유기굽힘의 구속효과 평가 모델)

  • Kim, Jin-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1134-1141
    • /
    • 2006
  • This paper presents the model for evaluating restraint effect of pressure induced bending (PIB) on the circumferential through-wall crack opening displacement (COD), which considers plastic behavior of crack. This study performed three-dimensional elastic-plastic finite element (FE) analyses for different crack angle, restraint length, pipe geometry, stress level, and material conditions, and evaluated the influence of each parameter on the PIB restraint effect on COD. Based on these evaluations and additional perfectly-plastic FE analyses, a closed-form model to evaluate the restraint effect of PIB on the plastic crack opening of circumferential through-wall crack, was proposed as functions of crack angle, restraint length, radius to thickness ratio, axial stress corresponding to an internal pressure, and normalized COD evaluated from linear-elastic crack opening condition.

고리 1호기 원자로냉각제 배관의 파단전누설 개념 평가

  • 우호길;송동수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.344-349
    • /
    • 1998
  • 고리 1호기 원전의 원자로냉각재 배관의 파단전누설개념 적용성을 평가하기 위하여 일반적인 파단전누설 절차 및 기준을 검토하였다. 파단전누설 타당성을 검토하기 위하여는 한계하중방법 및 J-T 방법을 비교검토 하였다. 그리고 원자로냉각재 배관에 대해서는 탄소강일 경우와 스테인레스강에 대하여 분석하였고, 가압기 밀림관에 대해서는 열응력을 계산하였다. 그리고 원자로 냉각재 배관에 가상의 관통균열의 파괴안전성은 유한요소법을 이용한 탄소성파괴역학을 통하여 분석하였다. 분석결과 한계하중법과 J-T 방법 모두 스테인레스강과 탄소강재질에 대해 적용 가능한 것으로 나타났다.

  • PDF

Damage Analysis of Singly Oriented Ply Fiber Metal Laminate under Concentrated Loading Conditions by Using Acoustic Emission (음향 방출법을 이용한 집중하중을 받는 일방향 섬유 금속 적층판의 손상 해석)

  • 남현욱;김용환;한경섭
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.46-53
    • /
    • 2001
  • In this research, damage behavior of singly oriented ply (SOP) fiber metal laminate (FML) subjected to concentrated load was studied. The static indentation tests were conducted to study fiber orientation effect on damage behavior of FML. During the static indentation tests, acoustic emission technique (AE) was adopted to study damage characteristics of FML. AE signals were obtained by using AE sensor with 150kHz resonance frequency and the signals were compared with indentation curves of FML. The damage process of SOP FML was divided by three parts, i.e., crack initiation, crack propagation, and penetration. The AE characteristics during crack initiation show that the micro crack is initiated at lower ply of the plate, then propagate along the thickness of the plate with creating tiber debonding. The crack grow along the fiber direction with occurring 60∼80dB AE signal. During the penetration, the fiber breakage was observed. As fiber orientation increases, talc fiber breakage occurs more frequently. The AE signal behaviors support these results. Cumulative AE counts could well predict crack initiation and crack propagation and AE amplitude were useful for the prediction of damage failure mode.

  • PDF

A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구)

  • Song, Suk-Jun;Yoo, Sang-Geon;Park, Ji-Woong;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1024-1029
    • /
    • 2009
  • According to increase of massive concrete structures, Thermal crack done by heat of hydration have been increased in a process of the execution. In case of a subway concrete box structure, thickness of structures are almost over 1 meter, and penetrating crack by external restraint takes a bad effect on the durability with a water leakage and deterioration in especially concrete wall. A try of shortening a constructing period often occurs as subway is generally constructed according to a road to decrease a traffic jam. The research proposes executing method by skipping one block as a plan of shortening a constructing period and investigate an influence on thermal cracking control. Additionally, sensitivity analysis is accomplished by changing a height of a concrete wall, and concrete placing and air temperature met with a field condition.

Influence of Stress Ratio of Elastic Waves Generated by Fatigue Crack Growth and Penetration in 6061 Aluminum Plates (6061알루미늄의 피로 균열 성장과 관통에 따른 탄성파의 응력비 영향)

  • Ahn Seok Hwan;Kim Jin Wook;Nam Ki Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.822-827
    • /
    • 2005
  • The characteristics of elastic waves emanating from crack initiation and propagation in 6061 aluminum alloy subjected to fatigue loading with different stress ratio was investigated. The objective of this study is to determine the properties of the signals generated from each stage of fatigue crack growth. AS a crack propagates, substantial elastic wave occurred just prior to penetration. Then it decreased and the crack penetrated. The waveforms and their power spectra were found to be dependent on the different stress ratio associated with the signals. It is determined that high-frequency signal $0.5{\sim}0.75$ MHz is most likely emitted during crack propagation at peak load of fatigue cycle which release the highest energy. It is determined that 0.3 MHz is closely related to crack closure effect. The frequency peaks below 0.25 MHz may be attributed to fretting or hydraulic noise.

Plastic Limit Pressure Solutions for Cracked Pipes Using 3-D Finite Element Method (3차원 유한요소해석을 통해 도출한 균열배관의 소성한계압력식)

  • Shim, Do-Jun;Huh, Nam-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.26-33
    • /
    • 2003
  • Based on detailed FE limit analyses, the present paper provides tractable approximations fer plastic limit pressure solutions fur axially through-wall-cracked pipe; axially (inner) surface-cracked pipe; circumferentially through-wall-cracked pipe; and circumferentially (inner) surface-cracked pipe. In particular, for surface crack problems, the effect of the crack shape, the semi-elliptical shape or the rectangular shape, on the limit pressure is quantified. Comparisons with existing analytical and empirical solutions show a large discrepancy in circumferential short through-wall cracks and in surface cracks (both axial and circumferential). Being based on detailed 3-D FE limit analysis, the present solutions are believed to be the most accurate, and thus to be valuable information not only for plastic collapse analysis of pressurised piping but also for estimating non-linear fracture mechanics parameters based on the reference stress approach.

Failure behavior analysis of a penetration type pile head stiffener (관통형 말뚝두부 보강의 파괴거동해석)

  • Park, Jun-Hwa;Moon, Keun-Ho;Lee, Gye-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.446-449
    • /
    • 2009
  • 본 연구에서는 강관말뚝과 기초와의 연결시 보강에 사용되는 관통형 말뚝두부보강에 대한 파괴거동을 파악하기 위한 구조해석을 수행하였다. 구조물의 관공부에 대한 해석에서 철근의 인장파괴시 발생하는 관통부의 응력을 검토하고 철근의 파괴형상과 실험에서 얻어진 철근의 파괴형상을 비교하였다. 대상구조물의 전체적인 파괴거동은 인장, 압축, 전단, 휨모멘트에 대하여 파괴가 발생할 때까지 변위를 증가시키고 이때 발생하는 반력과 구조물의 파괴거동을 파악하였다. 이 때 강재의 비선형 거동 및 충진콘크리트의 비선형및 균열거동이 고려되었다. 해석의 결과로 대상구조물의 파괴거동 및 극한하중 저항능력이 평가되었다.

  • PDF