• Title/Summary/Keyword: 관절방향각

Search Result 75, Processing Time 0.031 seconds

Study on Lower Extremities Activities Pattern of ADL and Treadmill Gait According to Harness Body-Weight Support Percentages (일상생활 동작 및 하네스 체중지지율에 따른 트레드밀 보행 시 하지 패턴에 관한 연구)

  • Song, S.M.;Yu, C.H.;Kim, K.;Kim, J.J.;Song, W.K.;Hong, C.U.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.4
    • /
    • pp.319-329
    • /
    • 2015
  • The purpose of this paper is to analyze lower extremities pattern of daily activities and walking on the treadmill with passive body support system. The experiments will be used for basic research of developing active harness system. The experimental procedure has been validated on 5 healthy male subjects and we measured foot pressure and 8 section of lower limb muscles activities. The EMG results of ADL indicate that there have specific muscle activity patterns followed by each activities. The vastus lateralis muscle activities were highly seems on the activities that requires flection and extension of knee joint. The foot pressure value of stair descent activity was the highest due to the fact that it is come down to the direction of gravity. The results with the passive body weight support percentages show that the EMG and foot pressure values were declined according to increasement of the body weight support percentages. Therefore the body weight support system could apply gait rehabilitation system for various patients by changing the percentages of the body weight support.

  • PDF

A Study of the Stability on Standing posture of Single leg in Yoga practicing (요가 수련을 통한 한발서기 자세의 안정화 연구)

  • Yoo, Sil;Hong, Su-yeon;Yoo, Sun-sik
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.6
    • /
    • pp.749-757
    • /
    • 2016
  • The purpose of this study was to investigate the effect of stability on one leg standing posture in yoga practice. Thirteen women college student who have never done yoga participated in this study. In order to collect data before and after yoga practicing for two years, we were used 3D motion capture system and electromyography. The results were as follows. First, ranges of motions for Y axis of left knee joint and X axis of right ankle joint were significantly different in dancer posture(p<.05), and then X axis of right ankle and Y axis of left ankle joint were significantly different in tree posture of pre and post training. Second, the planar alignment angle of trunk-pelvis was not significant difference in dancer and tree posture. Third, CoM-distances of Y, Z directions were significant difference in the tree posture(p<.05). Fourth, Muscle activities of both rectus abdominis, erector spinae and left quadriceps were significant difference in tree posture(p<.05). These findings suggested that yoga training played important roles in stable postures as results of decreasing rotation ankle joint and movement of CoM and enforcing core muscles. This study provides evidence for effectiveness of the stability on standing posture and can get a great effect on posture correction by means of yoga training. Hereafter, study on alignment angle, which is a measurement of postural stabilization will be needed by future yoga training.

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

Evaluation of Bonwill triangle using cone beam computerized tomography in Korean (콘빔형 전산화단층영상을 이용한 한국인의 본윌 삼각에 대한 평가)

  • Kong, Hyun-Jun;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the Bonwill triangle of Korean using the cone beam computerized tomography (Cone-beam CT). Materials and Methods: 120 Koreans (60 males and 60 females) who visited Daejeon Dental College Hospital of Wonkwang University and who underwent the Cone-beam CT were selected. The Cone-beam CT images were analysed with Invivo 5.1 (Anatomage, San Jose, USA). After reorientation of axis, the intercondylar distance was measured by clicking both middle points of condyle. And the condyle-incisor distance was measured by clicking the middle point of condyle and contact point of the mandibular central incisor's incisal edge. The collected data were analysed using the SPSS Version 23.0 (IBM Inc., Armonk, USA) and statistical significance was verified by gender using independent t-test. Results: The mean intercondylar distance of Korean was 105.9 mm, and the male (108.3 mm) was statistically significantly larger than the female (103.4 mm). The mean condyle-incisor distance of Korean was 105.2 mm, and the male (108.1 mm) was statistically significantly larger than the female (102.3 mm). Conclusion: The mean intercondylar distance of Korean in this study was 105.9 mm that was smaller than well-known 110 mm of Caucasian and the male was statistically significantly larger than the female. Within the limitations of this study, it would be necessary to use the articulator which can adjust the intercondylar distance according to the individual for prosthodontic treatment of Korean.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.

The Effect of Types of Abutment and Dynamic Loading on Microgap between Implant Fixture and Abutment (임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향)

  • Oh, Byung-Doo;Choi, Yu-Sung;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.389-403
    • /
    • 2010
  • Titanium and gold-alloy abutments have been used for a long-time in the clinical situations, but the use of zirconia abutments also increased. This study was designed to compare and evaluate the microgap differences according to types of abutment and dynamic loading. Titanium abutment, zirconia abutment and gold-alloy abutment (UCLA plastic) were connected into titanium implants of external hexagonal structure US II ${\phi}$ $3.75{\times}11.5$ mm (Osstem Co., Seoul, Korea) with the tightening torque of 30 Ncm. A sine type dynamic loading of 25-250 N and $30^{\circ}$ inclination from long axis was applied for $10^5$ times. Using the SEM both before and after the loadings, implant-abutment interfaces were analyzed on the labial, palatal, mesial and distal surface. The microgaps before and after the loading were compared, no statistically significant difference was observed caused by the dynamic loading on the labial, palatal, mesial or distal surface. Statistically significant difference was observed between UCLA and titanium group and between UCLA and zirconia group on both before and after the loading(p<0.05). No statistically significant difference was found between titanium and zirconia group. Loadings for $10^5$ times did not show significant effect to the microgaps between implants and abutments.

The Development of Classification System of Dental Services for Temporomandibular Joint Disorders (측두하악장애 의료행위분류에 관한 연구)

  • Song, Yun-Heon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.257-268
    • /
    • 2005
  • It is recently suggested in Korea that Resource-Based Relative Value Scale (RBRVS) is an alternative plan of Korean Dental Fee Schedule which has been operated on a fee-for-service basis since the introduction of the national health insurance program in 1977. RBRVS applicable to diagnosis and treatment for temporomandibular disorders (TMD), a common cause of orofacial pain, is needed to be estimated in Korea and the establishment of the standard terminology of dental procedures for TMD should be preceded. The purposes of this study were to develop a new classification system of health care service items for TMD and to investigate time needed for each item, which enables RBRVS to be estimated prior to establishment the payment system of health care services for TMD. The dental service items for TMD in this study were categorized through Delphi process which 10 TMD specialists were participated in and the time needed for each service item was investigated by work sampling and time study method with a stopwatch. The results of this study demonstrated the new classification system of dental services for TMD comprising 151 service items and exhibited the average time for each items ranging from 7.22 min for cold laser therapy to 171.71 min for direct fabrication of anterior repositioning splint. Conclusively, it is suggested that the classification system for TMD developed in this study, considering specific characteristics on basis of resources for health care service of dental procedures, should be helpful to estimate payment level for each service item.

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

Characteristic Analysis of Flexibility and Muscle Strength according to Exercise using Lumbar Strengthen Exercise Instrument (요추강화 운동기기의 훈련을 통한 유연성 및 근력 특성 분석)

  • Kang, S.R.;Kim, K.;Jeong, G.Y.;Moon, D.A.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In this paper, We investigated the characteristic analysis of flexibility and muscle strength for exercise to verify capacity in rehabilitation exercise of lumbar using lumbar strengthen exercise instrument. We have experiment in 20th years man and woman who are 20 subject with no medical history, we divided subjects into control group with no exercise and training group with lumbar strengthen exercise. We used Hi-Spine(Medicalscience.korea) also, provided exercise 40 minute a day, three days a week and progressed total four weeks. Moreover in our experiment, subjects exercised four postural position as lay down, sit, stand and stretch each ten minute. We measured trunk extension backward, trunk flexion forward, evaluation of based physical fitness and lumbar joint torque. The reults have shown that there more improved all for flexibility, based physical fitness and lumbar joint torque in training group than control group. We indicated that by rotating 3-D axis movement flatform of exercise instrument, muscle spindle in subject have been stimulated and these rotation direction and angle caused muscle tonus and contraction that makes muscle, flexibility and based physical fitness improve more. Our study can be used rehabilitation exercise program to aged people and patient with lumbar injury.