• Title/Summary/Keyword: 관심 영역

Search Result 2,425, Processing Time 0.035 seconds

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

Evaluation on Spectral Analysis in ALOS-2 PALSAR-2 Stripmap-ScanSAR Interferometry (ALOS-2 Stripmap-ScanSAR 위상간섭기법에서의 스펙트럼 분석 평가)

  • Park, Seo-Woo;Jung, Seong-Woo;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.351-363
    • /
    • 2020
  • It is well known that alluvial sediment located in coastal region has been easily affected by geohazard like ground subsidence, marine or meteorological disasters which threaten invaluable lives and properties. The subsidence is a sinking of the ground due to underground material movement that mostly related to soil compaction by water extraction. Thus, continuous monitoring is essential to protect possible damage from the ground subsidence in the coastal region. Radar interferometric application has been widely used to estimate surface displacement from phase information of synthetic aperture radar (SAR). Thanks to advanced SAR technique like the Small BAseline Subset (SBAS), a time-series of surface displacement could be successfully calculated with a large amount of SAR observations (>20). Because the ALOS-2 PALSAR-2 L-band observations maintain higher coherence compared with other shorter wavelength like X- or C-band, it has been regarded as one of the best resources for Earth science. However, the number of ALOS-2 PALSAR-2 observations might be not enough for the SBAS application due to its global monitoring observation scenario. Unfortunately, the number of the ALOS-2 PALSAR-2 Stripmap images in area of our interest, Busan which located in the Southeastern Korea, is only 11 which is insufficient to apply the SBAS time-series analysis. Although it is common that the radar interferometry utilizes multiple SAR images collected from same acquisition mode, it has been reported that the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometric application could be possible under specific acquisition mode. In case that we can apply the Stripmap-ScanSAR interferometry with the other 18 ScanSAR observations over Busan, an enhanced time-series surface displacement with better temporal resolution could be estimated. In this study, we evaluated feasibility of the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometric application using Gamma software considering differences of chirp bandwidth and pulse repetition frequency (PRF) between two acquisition modes. In addition, we analyzed the interferograms with respect to spectral shift of radar carrier frequency and common band filtering. Even though it shows similar level of coherence regardless of spectral shift in the radar carrier frequency, we found periodic spectral noises in azimuth direction and significant degradation of coherence in azimuth direction after common band filtering. Therefore, the characteristics of spectral bandwidth in the range and azimuth direction should be considered cautiously for the ALOS-2 PALSAR-2 Stripmap-ScanSAR interferometry.

Nursing Professor's inspection and Status of Patient's Records and Informed Consent for Clinical Practice of Nursing Student in Korea and Japan (한·일 간호대학생의 임상실습 시 환자의 설명동의 및 기록관리와 지도실태)

  • Cho, Yooh-Yang;Kim, In-Hong;Yamamoto, Fujie;Yamasaki, Fujiko
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.1
    • /
    • pp.35-46
    • /
    • 2006
  • Objectives: In recently. the management and protection on individual information in patient's medical & nursing records have been very important, and that need a guideline. The purpose of this study was to investigate the status of using the patient's nursing records of nursing students in clinical practice, to find and discuss the patient's informed consent, and status of education and management concerned to patient's nursing records. Methods: This study used a mailing survey. data collected from September 24th to October 31th in 2002. The subject were 333 professors who are major in adult nursing, pediatric nursing, psychological nursing of 111 university of nursing department and nursing college. And then we received the survey mail from 103 professors that respondent rate was 30.9%. Results: The characteristics of study subjects showed 49.0% of university. 51.0% of college of nursing. 50.0% of the subjects practiced point the patient by oral approval in clinical practice. But when the decision of the patient was very difficult, 21.6% of the subjects take to informed consent from his or her families. During the clinical practice, 49.0% of the subjects were explain to patient about clinical practice and contents of the nursing student, only 7.8% of the subjects were explain to patient with nursing records. 52.0% of the subjects were took out records from the hospital, only 17.6% of the subjects had standard of the patient's informed consent and standard of handling practice records. 17.6%-92.2% of the subjects that educate and manage concern to patient's nursing records.

  • PDF

A study on the self-concept and the appearance management behavior in middle school students' (중학생의 자아개념과 외모관리행동 연구)

  • Lee, Jin-Young;Wee, Eun Hah
    • Journal of Korean Home Economics Education Association
    • /
    • v.25 no.3
    • /
    • pp.19-38
    • /
    • 2013
  • This study focuses on the differences in general self-concept, academic self-concept, significant others self-concept and emotional-physical self-concept in relation to appearance management behavior. It goes on to show that appearance management behaviors such as styles in clothing, makeup, skin care, hair care, cosmetic surgery and body shaping, weight control management are strongly influenced by self-concept. Therefore, this study was carried out with the aim of providing basic understanding and information on the appearance management behavior of middle school students. It was also done in an effort to find ways of improving the self-concept of students through education as a part of the domestic science curriculum. The results obtained in this study are as follows: On average, the middle school students who took part in this study showed low self-concept and appearance management behavior which indicates a negative image of themselves. This suggests that efforts need to be made so that students can see themselves in a positive way and improve their self-concept through appearance management behavior. Middle school students with a positive self-concept try to present themselves by keeping their skin clean and their hair attractive. They express their self-esteem and personality through fashion and by keeping and maintaining their clothing, shoes and bags. They also tend to show a positive attitude towards their studies and are more likely to understand and get along with others. The students who showed positive attitudes towards their bodies and emotions have a higher interest in clothing and try to express the image that they want for themselves. They are also less likely to change their bodies unnaturally through cosmetic surgery and body shaping. Appropriate appearance management behavior can help middle school students see themselves in a more positive way.

  • PDF

A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA) (단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법)

  • Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Kim, Dong-Hyun;Jeon, Ho-Sang;Nam, Ji-Ho;Lim, Sang-Wook
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.340-347
    • /
    • 2010
  • DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the ${\gamma}$-index analysis. In ${\gamma}$-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the ${\gamma}$-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than $24.3{\times}16.6cm^2$ the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.

Preoperative Evaluation of Brain Lesion with $^{201}Tl$ Brain SPECT: Is It Useful to Differentiate Benign and Malignant Lesions? (수술 전 뇌 병변의 $^{201}Tl$ 뇌 SPECT: 양성과 악성 병변을 감별하는데 유용한가?)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Chung, Yong-An;Chung, Soo-Kyo;Bong, Yong-Gil;Lee, Youn-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.371-380
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT, which can represent cellular activity of brain lesions, may provide more useful information in differentiating between benign and malignant brain lesions more so than CT of MRI, that merely represents anatomic changes or breakdown of blood brain barrier. We used $^{201}Tl$ brain SPECT prospectively to evaluate the utility of $^{201}Tl$-indices as an indicator of benign or malig nant lesions. Materials and Methods: We studied 28 patients. There were 13 cases of benign lesions (3: nonspecific benign lesion, 3: meningioma, 2: low grade glioma, 1: tuberculoma, central neurocytoma, hemangioblastoma, radiation necrosis, and choroid plexus papilloma) and 15 cases of malignant lesions (6: glioblastoma multiforme, 5: anaplastic glioma, 2: medulloblastoma, 1: metastasis and lymphoma). In all patients, CT and/or MRI were obtained and then $^{201}Tl$ brain SPECT was obtained with measuring mean $^{201}Tl$ index and peak $^{201}Tl$ index. An unpaired t-test was performed to compare the $^{201}Tl$-indices and pathologic diagnoses to evaluate the utility of $^{201}Tl$-indices as all indicator of benign or malignant lesions. Results: There were no statistically significant difference in $^{201}Tl$-indices between benign and malignant brain lesion (p>0.05). Conclusion: These results demonstrated that we could not use $^{201}Tl$ indices on brain SPECT alone as an indicator of benign or malignant brain lesions.

  • PDF

Preliminary Landscape Improvement Plan for Gu-ryong Village (구룡 해안마을 경관형성 기본계획)

  • Kim, Yun-Geum;Choi, Jung-Min
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.23-34
    • /
    • 2012
  • This Study is about the "Comprehensive Landscape Improvement Plan for Gu-ryoung Seaside Village that was one of most exhibited projects for developing sea villages." The formulations of the plan were supervised by the Ministry of Land, Transport, and Maritime Affairs and were executed by the Goheung Country. Rather than proposing renovations for the landscape, this study maintains the existing order and attempts to examine the plan by scrutinizing the vernacular design language of the landscape. In the study, community members had the opportunity to express their opinions and ideas about the community through workshops composed of community participation programs, and participated in the decision-making process through consultation meetings. The conclusion of this study was relevant to the activities of the committee on landscape improvement. The Comprehensive Landscape Improvement Plan has three objectives: (1) resorting and modifying the natural landscape, (2) restructuring the roadways, and (3) modifying key spaces. In the end, the role of Gu-ryong Mountain as a background of the landscape was focused on tree planting drives that were undertaken, and accessibility to the sea front was improved. Second, in restructuring the roadways, rough roads were restored and unconnected roads were connected to ensure a network of roads along the sea front, inner roads in the village, roads at the Fringes Mountains, and stone roads on the mud flat. In addition, roads were named according to the character of the landscape and signs were installed. Finally, the existing key spaces, in which community members came together, were restored and new key spaces were created for the outdoor activities of the inhabitants and the diverse experience of visitors. A guideline was also created to regulate private areas such as roofs, walls, fences of residential buildings, and private container boxes and fishing gear along the sea front. The strength of this study is that it is seeking to determine the greatest potential of the landscape and set the plan by examining the lives of community members. Some problems were found during the development of this study. Further, there were problems in the community's understanding as elaborated below. First is the gap between community members' awareness and practice. Even though they were aware of the problems with the village landscape, they hesitated to implement improvements. Second, community members have misunderstandings about the landscape the improvement plan. The local government and the residents have understood this plan as a development project; for example, new building construction or the extension of roads. Third, residents are not aware that continuous attention and improvements are required for the upkeep of the landscape in the sea village. The plan to improve the landscape should promote a balance between making the area as a tourist attraction and maintaining the lives and cultural activities, because the sea village system incorporates settlements, economy, and culture.

The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times (상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구)

  • Kim In-Sung;Lee Young-Ju;Kim Ju-Hyun;Sujit Dutta;Kim Suk-Kyung;Kim Tae-Jeong;Kang Duk-Sik;Chang Yong-Min
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2006
  • To evaluate the T1, T2 magnetic relaxation properties of water molecule according to molecular weight of paramagnetic complex. 4-aminomethyicyclohexane carboxylic acid (0.63 g, 4 mmol) was mixed with the suspension solution of DMF (15 ml) and DTPA-bis-anhydride (0.71 g, 2 mmol) to synthesize the ligand. The ligand was then mixed with $Gd_2O_3$ (0.18 g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1 mM and then the relaxation times were measured at 1.57 (64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG (Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. In case of inversion recovery sequence, total 35 images with different inversion time(T1)s ranging from 50 msec to 1,750 msec. To estimate the relaxation times, the signal intensity of each sample was measured using region of Interest (ROI) and then fitted by non-linear least square method to yield T1, T2 relaxation times and also R1 and R2. Compared to T1=($205.1{\pm}2.57$) msec and T2=($209.4{\pm}4.28$) msec of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, T1 and T2 values of new paramagnetic complexes were reduced along with their molecular weight. That is, T1 value was ranged from $(96.35{\pm}2.04)\;to\;(79.38{\pm}1.55)$ msec and T2 value was ranged from $(91.02{\pm}2.08)\;to\;(76.66{\pm}1.84)$ msec. Among new paramagnetic complexes, there is a tendency that the R1 and R2 increase as the molecular weight is increases. As molecular weight of paramagnetic complex increases, T1 and T2 relaxation times reduce and thus the increase of relaxivity (R1 and R2) Is proportional to molecular weight.

  • PDF

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

Does the ADC Map have Additional Clinical Significance Compared to the DWI in the Brain Infarction? (뇌경색에서 확산강조영상과 비교하여 현성확산계수 지도의 부가적인 임상적 중요성이 있는가?)

  • Choi, Sunseob;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin Hwa;Yoon, Seong Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.267-274
    • /
    • 2013
  • Purpose : To re-evaluate additional clinical significance of the apparent diffusion coefficient (ADC) map in the inference of infarction stage, authors studied the evolution patterns of the DWI and the ADC map of the brain infarction. Materials and Methods: In 127 patients with cerebral infarctions, including follow-up checks, 199 studies were performed. They were classified as hourly (117 studies)-, daily (108 studies)-, weekly (62 studies)-based groups. The signal intensity (SI) was measured at the core of the infarction and contralateral area with ROI of 0.3 $cm^2$ or more on the images of the DWI and the ADC map, and calculated the ratios of SI and ADC value of the infarction area / contralateral normal area, and compared the patterns of the change according to the evolution. Results: Infarction was detected as early as 1 hour after the attack, and the ratio of SI in the DWI became over than 2 after 12 hours, which showed a plateau until the 6th day. Thereafter, it decreased slowly to 1 on the 30th day, and changed to lower SI than the surrounding brain. The ratio in the ADC map became 0.46 in 24 hours after the attack, and increased slowly to 1 in the 15th day. Thereafter, it became a higher value than the surrounding brain. Overall, the ratio in the ADC map changed earlier than in the DWI, and the ratio curves showed inverse pattern each other according to the evolution of the infarction. Conclusion: The evolution patterns of infarction on the ADC map showed an inverse curve of DWI curve, which means that the ADC value is accurately predictable from DWI, and the ADC map joined with the DWI seems helpful in the determination of subacute infarction between 15 to 30 days.