• Title/Summary/Keyword: 공동 주택

Search Result 2,630, Processing Time 0.023 seconds

A Competitive Advantage Analysis of Construction Duration through the Comparison of Actual Data of Domestic Construction Firms - Focused on Mix-Use Residential Building and Officetel Building - (건설사별 공기비교를 통한 공기경쟁력 분석 - 주상복합 및 오피스텔 건물을 중심으로 -)

  • Ryu, Han-Guk;Kim, Sun-Kuk;Lee, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.1 s.29
    • /
    • pp.138-147
    • /
    • 2006
  • Construction companies have been interested in the construction duration which importantly affects the performance and the success of the construction projects in accordance with the systemic changes such as five days per week system, introduction of construction duration reduction bidding system and post sale system nowadays. It is also very important to estimate and forecast properly the construction duration as the construction companies compete for the projects in the situation of construction market reduction and the lowest bidding system. Recognizing the importance about the construction duration, the researches about comparing and analyzing or estiamting the construction duration have been performed. However, comparing studies about the construction duraion have been limited to the apartment and office building in domestic area. Many studies about forecasting construction duration have been performed through stochastic analysis and simulations. Little research has been addressed the comparison analysis of the real construction duration about the mix-use building and officetel building which occured according to the changes of the building requirements. Therefore, the objective of this study is to compare and analyze the real construction duration and the hypothetical construction duration about the mix-use building and officetel building of the domestic companies. Moreover, we select the most competitve construction company to get the strengths and analyze the competitive advatages of the construction companies about construction duration.

Economic Evaluation of Eco-friendly Demolition Work and Case study in Remodeling Project (친환경 리모델링 철거공사의 경제성 평가 및 사례적용)

  • Kim, Yoon-Duk;Kim, Ki-Hyun;Cha, Hee-Sung;Kim, Kyung-Rai;Shin, Dong-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.2
    • /
    • pp.45-53
    • /
    • 2010
  • When increasing quantity of construction wastes, how to deal with construction wastes and environmental problems relating to disposal of construction wastes are discussed as social issues, treatment of construction waste and subsidiary issues are raised as important problems. The demolition work produce construction wastes most in construction industry. Various researches on eco-friendly treatment of construction wastes, recycling rates and recycled materials were conducted aspect of sustainability in developed countries, however, domestic remodeling projects were performed demolition work with first-demolition and second-classification method which emphasize productivity focused on efficiency. It caused not only environmental problems, but also economical problems such as increasing disposal cost of construction wastes. Solving these problems, the previous study, suggested the process model of eco-friendly demolition work to recycle materials. This paper applied eco-friendly remodeling process to practical projects and economic feasibility on eco-friendly remodeling process. Moreover these results expect to contribute the revitalization of eco-friendly demolition work in remodeling projects.

A Study on Duration Calculation Method for Eco-Friendly Remodeling Demolition Work Using Productivity Analysis (생산성 분석에 기초한 친환경 리모델링 철거공사 기간 산출 방안)

  • Woo, Joong-Pyung;Cha, Hee-Sung;Kim, Kyung-Rai;Shin, Dong-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.1
    • /
    • pp.124-132
    • /
    • 2013
  • An influx of the population to the city has soared due to industrialization. As times go by, cities become densely populated so Korean government started to construct a number of buildings including apartment housings. Because they have become functionally, structurally, esthetically deteriorated over the past two decades. some improvements are needed. There are mainly two ways to improve old buildings: remodeling and reconstruction. Between the two, the first one is more popular as it is less time-consuming and more eco-friendly. Demolition work comes first for both of them and it should not give negative effects since it is regarded as a CP(Critical path) in the overall process. For this reason, a thorough construction management must be done. The reality, however, demolition is managed by the construction manager's experiences and decisions. If the key factor of demolition which is the planning of manpower and machine equipment, is determined by unscientific and subjective judgments, its period and risk also will increase. In particular, eco-friendly demolition can be more risky because it's been rarely conducted. Therefore, scientific and objective ways of demolition management are needed. In this context, this paper aims at analyzing productivity in each process of demolition focusing on manpower and machinery equipment which are the main parts of demolition assuming that the demands of eco-friendly remodeling demolition projects will be increasing. At the same time, by estimating working period through the output, this paper would be helpful to set up the plans for overall project in earlier stage.

A Study on the Analysis of Apartment Price affected by Urban Infrastructure System - Electricity Substation (도시기반시설이 공동주택가격에 미치는 영향분석에 관한 연구 - 전력통신시설(변전소)을 중심으로 -)

  • Hwang, Sungduk;Jeong, Moonoh;Lee, Sangyoub
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.74-81
    • /
    • 2015
  • As one of urban infrastructure system, the electricity substation is critical for urban life and industrial activity as the electricity demands get higher than ever. However the substation is generally regarded as unpleasant or dangerous facility, which finally results in the continuous opposition movement by resident due to the belief of unidentified negative effect in apartment prices. Accordingly, as the scientifically objective and quantitative analysis is required to solve the social conflict, this study intends to examine the variation affected by urban infrastructure system, expecially for substation. After the independent variable defining the price of apartment and the dependent variable, which is apartment price, are identified and their spatial data has been filed, the forecasting model has been developed through the hedonic price function as well as artificial neural networks system. The research finding indicated that the spatial range affected by substation is not notable and the range of some case was applicable for less than 600m. It is expected that these research findings can be applied for establishing the one of solid cases for the analysis of economical effect to local housing market by the urban infrastructure system.

Development of a Systemized Flying Net for Safety Improvement in Architectural Building Construction (건설 공사의 안전성 향상을 위한 충돌방지형 시스템 플라잉넷의 개발)

  • Lee, Jeong-Ho;Park, Seon-Joo;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.5
    • /
    • pp.71-80
    • /
    • 2011
  • Flying net should be installed on every 3 or 4 construction floor from 8m above ground according to the rule. In the apartment housing construction, flying net installation work has been recognized the most dangerous work among the whole works because a small mistake of labors might make their death accident. Sub-contractors specialized in flying net have been developing various flying net types. However, most works of installing flying net as working with the developed system are performed outside the apartment housing, so that the risk of fall in works of installing supports and unfolding net is still high. Furthermore, as using the previously developed flying net labors might bump into the frame or the wire rope for supporting so that it makes secondary accidents. The objective of this research is to produce the proto-type of anti-collision flying net system based on the result of problem analysis on the installation and detachment process and suggest the improved anti-collision flying net system, which is able to improve safety and field applicability by conducting field experiment and analyzing performance.

Study on the Extension of Reinforced Concrete Slabs (철근콘크리트 바닥판 평면확장 공법에 대한 연구)

  • Kim, Jin-Pyeng;Kim, Sang-Sik;Choi, Kwnag-Ho;Jeon, Byong-Gap;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.321-330
    • /
    • 2006
  • In order to remodel old aged reinforced concrete buildings, it is often required to extend the residence area of the buildings by increasing the slab area. The slab area is usually extended by attaching a new slab to the existing slab with hinged joint or rigid joint. Transmission of the loads of the attached slabs to the existing slabs depends on the connecting methods, such as hinged or rigid connection. In this research, 8 specimens and 24 RC slabs connected by rigid joints were tested. The new slab was connected to the existing slab by three types of rigid joints using dowel bars and longitudinal tensile bars. Main parameters of the slabs were three types of the rigid joints, anchor length of steel bars(0, 50, 60, 100, and 120mm), development length of steel bars(100, 200, and 300mm), and the spacing of the steel bars(150, 200, 300, and 450mm). The test results indicated that the flexural strength of the RC test slabs having various types of rigid joints was approximately the same to that of the slab without any connections.

Reversed Cyclic Load Tests on Deep Beam-and-Exterior Column Joints (깊은보-외부기둥 접합부의 반복 횡하중 실험)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.265-273
    • /
    • 2007
  • The most common structural system for apartment buildings in Korea is adopted to combine structural systems: for example, a moment-resisting frame will be used for lower stories and bearing wall system for the upper stories. This type of buildings have soft and/or weak stories in lower stories, and it may lead to collapse of those buildings during the large earthquake. Reversed cyclic load tests were conducted to estimate the performance and behavioral characteristics of deep beam and exterior column Joints. Experimental parameter is the amount of transverse reinforcement (designed by ACI code and Sheikh's procedure). The results of this study are as follows: (1) The required transverse reinforcement of column designed by Sheikh's procedure requires 2.9 times larger than that designed by ACI procedure. Large amount of transverse reinforcement increase the ductility of the column. (2) Most of the lateral drift in the column is due to the flexural deformation in the joint and plastic hinge region and up-lift rotation. (3) Transverse reinforcement in the exterior column shall be required not only in the hinge region but also in the joint.

Characterization of airborne bioaerosol concentration at the apartment in chungnam area (충남 지역 공동주택의 미생물농도 분포특성에 대한 연구)

  • Son Bu-Soon;Chun Jae-young;Yang Won-ho;Chung Tae-Woong
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.21-30
    • /
    • 2005
  • This research was performed to measure the concentration distribution of bioaerosol in apartment houses in the region of Chungnam (Chunan, Asan) for 1 month, December, 2004. The results are as follows. 1. By using SDA method, the average concentration of total microbe and fungus in the air inside and outside apartment house below 4 years are $69,42cfu/m^3\;and\;15.66cfu/m^3$, while apartment house over 4 years, $214.58cfu/m^3\;and\;216.43cfu/m^3$, respectively With gravitational sedimentation method, the average concentration of total microbe and fungus of apartmenthouse below 4 years are $100.63cfu/m^3\;and\;22.83cfu/m^3$, while apartment house over 4 years, $216.43cfu/m^3\;and\;70.000cfu/m^3$, respectively. 2. The I/O ratio of floating germ of apartment house below 4 years and over 4 years are 2.87 and 5.12 for total microbe, and 3.32 and 8.28 for fungus, respectively. The I/O ratio of falling germ of apartment house below 4 years and over 4 years are 1.55 and 2.81 for total microbe, and 2.85 and 4.08 for fungus, respectively. The apartment house below 4 years shows a low I/O ratio in all cases. 3. The difference in concentration of microbe between inside master bedroom and living room of apartment house below 4 years is $13.183cfu/m^3$, total microbe, and $4.787cfu/m^3$, fungus, while, apartment house over 4 years, $43.531cfu/m^3$, total microbe, and $21.932cfu/m^3$, fungus. The measured differences are statistically significant. 4. Air sampler was used to verify the difference in concentration of microbe with the age of apartment house. The difference in concentration of total microbe and fungus for outside apartment house below 4 years and over 4 years are $49.82cfu/m^3$ and $3.78cfu/m^3$, respectively. The difference of inside living room shows $160.23cfu/m^3$ for total microbe and $28.01cfu/m^3$ for fungus, and the difference of inside master bedroom shows $225.43cfu/m^3$ for total microbe and $56.73cfu/m^3$ for fungus. The differences are statistically significant. The difference in concentration of outside apartment house below 4 years and years 4 years are $34.66cfu/m^3$, total microbe, and $15.66cfu/m^3$, fungus, while inside apartment house below 4 years and over 4 years, $196.93cfu/m^3,\;and\;78.67cfu/m^3$, respectively. The measured differences are statistically significant.

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

Effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space (주거 공간에서 고령자 청력손실을 고려한 소음 및 잔향에 따른 음성 전송 성능의 주관적 평가)

  • Oh, Yang Ki;Ryu, Jong-Kwan;Song, Han-Sol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.369-377
    • /
    • 2018
  • This study investigated the effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space through listening test. Floor impact, road traffic, airborne, and drainage noise were employed as the residential noise, and several impulse responses were obtained through room acoustical computer simulation for an apartment building. Sound sources for the listening test consisted of residential noises and speech sounds for boh the young (the original sound) and the aged (the sound filtered out by filters with frequency responses of hearing loss of 65 years elderly person). In the listening test, subjects evaluated speech intelligibility and listening difficulty for the presented word ($L_{Aeq}$ 55 dB) at three noise levels ($L_{Aeq}$ 30, 40, 50 dB) and three reverberation times (0.5, 1.0, 1.5 s). Results showed that the residential space with noise level lower than equal to 50 dB ($L_{i,Fmax,AW}$) for jumping noise and 40 dB ($L_{Aeq}$) for road traffic, airborne, and drainage noise had speech intelligibility of 90 % and over and listening difficulty of 30 % and below. Speech intelligibility and listening difficulty for the aged sound source was shown to be 0 % ~ 5 % lower and 2 % ~ 20 % higher than those for the young sound source, respectively.