• Title/Summary/Keyword: 공기 냉각기

Search Result 139, Processing Time 0.024 seconds

A brief review of recent Antarctic climate change (최근 남극의 기후변화 고찰)

  • Seong-Joong Kim;Chang-Kyu Lim
    • The Korean Journal of Quaternary Research
    • /
    • v.32 no.1_2
    • /
    • pp.30-40
    • /
    • 2018
  • In response to the increase in anthropogenic greenhouse gases, the Arctic temperature is increasing rapidly by 2-3 times other regions. This larger Arctic warming than lower latitudes is called 'Arctic Amplification'(Overland et al., 2017; Goose et al., 2018). Associated with the Arctic Amplification, the Arctic sea ice is declining rapidly and Greenland ice sheet is melting rapidly, especially around the coastal margins (State of Climate, 2018). However, Antarctic climate change appears to be different from the Arctic. In the western part of Antarctica, surface temperature is rising rapidly with large sea and land ice melting, but in the eastern part, there is little temperature change with slight increase in sea ice extent. The contrasting east-west temperature response is illustrated by the deepening of the Amundsen Sea Low whose upstream brings warm maritime air to the Antarctic peninsula and Amundsen-Bellingshausen Seas, but downstream air provides cold air to the Ross Sea, increasing sea ice. Besides, the increase in Southern Annular Mode (SAM) phase due to stratospheric ozone reduction enhances westerly winds, pushing sea ice northward by Ekman divergence and cooling east Antarctica. In this study, we review the recent Antarctic climate change and its possible causes.

Temperature Distributions of Inner Microwave for Various Working Conditions (구동조건에 따른 전자레인지 내부 온도 분포)

  • Choi, Yoon-Hwan;Kim, Dong-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.792-797
    • /
    • 2010
  • Microwave oven and household cooker are devices of high voltage producer and high voltage storage batteries respectively for formation of necessary high frequencies at drive. These devices emit much heat energy because they are run at high voltages. Therefore, emitted heat energy becomes a factor that raises temperature of microwave ovens' main frame. In this research, the analysis shows the temperature distribution in microwave oven with the cooling fan drive conditions and the heat energy occurrence conditions. According to the analysis, as the speed of air outpoured in cooling fan increases, and the internal temperature decreases quantitatively. Also the inside temperature distribution was investigated by controlling heat energy emission.

A Study on Optical Properties of Aspheric Glass Lens using DLC Coated molding core (성형용 코어면 DLC 코팅에 의한 비구면 Glass렌즈 광학적 특성에 관한 연구)

  • Kim, Hyeon-Uk;Jeong, Sang-Hwa;Cha, Du-Hwan;Lee, Dong-Gil;Kim, Sang-Seok;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.243-244
    • /
    • 2007
  • 본 연구에서는 성형용 코어 가공에서 초경합금(WC, Co 0.5%)의 초정밀 가공특성을 파악하기 위하여 다이아몬드 휠의 메시, 주축 회전속도, 터빈 회전속도, 이송속도 및 연삭깊이에 따른 표면거칠기를 측정하여 최적연삭조건을 규명하였다. 규명된 최적연삭가공조건을 활용하여 페러렐 연삭법으로 초정밀 연삭가공을 수행하였다. 연삭가공은 초정밀가공기(ASP01, Nachi-Fujikoshi Co., Japan)를 사용하였다. 최종 정삭가공을 수행한 비구면 성형용 코어의 형상측정결과 형상정도(PV; ${\varphi}$ 3.0mm) 0.15${\mu}m$(비구면), 0.10${\mu}m$(평면)으로 3M급 이상의 고화질 카메라폰에 채용되고 있는 비구면 Glass렌즈 양산용 성형용 코어 규격에 만족한 결과로서 본 연구에 수행된 초정밀 가공조건 및 측정방법이 매우 유효함을 알 수 있었다. 형상정도(PV) 및 표면조도(Ra) 측정은 초정밀 자유곡면 측정기(UA3P, Panasonic Co., Japan)와 3차원 표면조도 측정기(NewView5000, Zygo Co., USA)를 각각 사용하였다. 초정밀 가공된 성형용 코어면에 이온증착법을 활용하여 DLC 코팅을 수행하였다. 코팅 전후의 성형용코어를 활용하여 Glass소재(K-BK7, Sumita Co., Japan)를 최적의 성형조건(성형온도, 압력, 냉각속도)으로 성형하였다. DLC 코팅과 성형은 DLC 코팅기(NC400, Nanotech Co., Japan)와 Glass렌즈 성형기(Nano Press-S, Sumitomo Co., Japan)을 각각 사용하였다. Fig. 1은 초정밀 연삭가공, DLC 코팅막 구조, 코팅된 성형용 코어, 그리고, 성형된 비구면Glass렌즈를 각각 나타낸다.

  • PDF

Exergetic Analysis of Ammonia-fueled Solid Oxide Fuel Cell Systems for Power Generation (암모니아 활용 고체산화물 연료전지 발전시스템의 엑서지 분석)

  • Thai-Quyen Quach;Young Gyun Bae;Kook Young Ahn;Sun Youp Lee;Young Sang Kim
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • Using ammonia as fuel for solid oxide fuel (SOFC) cells has become an attractive topic nowadays due to its high efficiency, environmental friendliness, and ease of storage and transportation. Several configurations of ammonia-fed SOFC systems have been proposed and investigated, demonstrating high electrical efficiency. However, to further enhance efficiency, it is crucial to understand the inefficient components of the system. The exergy concept is well-suited for this purpose, making exergetic analysis essential for ammonia-fed SOFC systems. This study conducts an exergetic analysis for three selected systems: a simple fuel cell system (FC), an anode off-gas recirculation system (RC-FC), and a recirculation system with water removal (RC-WR-FC). The results reveal that the exergetic efficiencies of the FC, RC-FC, and RC-WR-FC are 48.7%, 51.6%, and 58.4%, respectively. In all three systems, the SOFC stack is the main source of exergy destruction. However, other components with relatively low exergetic efficiency, such as the burner, air heat exchanger, and cooler/condenser, offer greater opportunities for improvement.

Simulation and Experimental Study on an Air-Cooled $NH_3/H_2O$ Absorption Chiller (공랭형 $NH_3/H_2O$ 흡수식 냉동기의 모사 및 실험적 연구)

  • Oh Min Kyu;Kim Hyun Jun;Kim Sung Soo;Kang Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1028-1034
    • /
    • 2005
  • The objective of this paper is to study the effects of the cooling air mass flow rate and the heat input variation by the simulation and the experiment. An air-cooled $NH_3/H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect machine is 17.6 kW (5.0 USRT). The overall conductance (UA) of each component, the cooling capacity, coefficient of performance and each state point are measured with the variation of the cooling air mass flow rate and the heat input. It is found that the COP and cooling capacity increase and then decreases with increasing the heat input. It is also found that the COP and the cooling capacity increase and keep constant with increasing the cooling air mass flow rate. The maximum COP is estimated as 0.51 and the optimum cooling air mass flow rate is $217\;m^3/min$ from the present experiment.

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Analysis of Loss of HVAC for Nuclear Power Plant (원전의 공기조화설비(HVAC) 상실사고 분석방법)

  • Song, Dong-Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2014
  • Environmental qualification (EQ) for safety-related equipment is required to ensure that those equipment will perform their required function even under the harsh environment conditions arising from design basis accident in the nuclear power plant. As a part of EQ program, the room temperature analysis in case of a loss of Heating, Ventilation, and Air Conditioning(HVAC) system was carried out to ensure the operability of the safety-related equipment of a nuclear power plant randomly chosen among the Korean nuclear power plants. In this paper, this analysis was performed in the conservative perspective using GOTHIC code. The room temperature analysis includes selecting the rooms in which the safety related equipment are located but not supported by safety related HVAC and determining the temperature of the selected rooms. Target rooms for the analysis consist of W229/W237 (Aux. feedwater pump room), W232 (Aux. feedwater tank room) and W230 (Equipment passageway). The results showed the temperature range from $43^{\circ}C$ to $83^{\circ}C$, in 72 hours after a loss of HVAC. Those values are far below of generic EQ temperature($171^{\circ}C$). Therefore, it is satisfied with EQ requirement of temperature limits on safety related equipment.

Effects of Biomass Gasification by Addition of Steam and Calcined Dolomite in Bubbling Fluidized Beds (기포유동층에서 수증기 및 소성된 백운석 첨가에 의한 바이오매스 가스화의 영향)

  • Jo, WooJin;Jeong, SooHwa;Park, SungJin;Choi, YoungTai;Lee, DongHyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.783-791
    • /
    • 2015
  • A fluidized-bed reactor with an inside diameter of 0.1 m and a height of 1.2 m was used to study the effect of steam and catalyst additions to air-blown biomass gasification on the production of producer gas. The equipment consisted of a fluidized bed reactor, a fuel supply system, a cyclone, a condenser, two receivers, steam generator and gas analyzer. Silica sand with a mean particle diameter of $380{\mu}m$ was used as a bed material and calcined dolomite ($356{\mu}m$), which is effective in tar reduction and producer gas purification, was used as the catalyst. Both of Korea wood pellet (KWP) and a pellet form of EFB (empty fruit bunch) which is the byproduct of Southeast Asia palm oil extraction were examined as biomass feeds. In all the experiments, the feeding rates were 50 g/min for EFB and 38 g/min for KWP, respectively at the reaction temperature of $800^{\circ}C$ and an ER (equivalence ratio) of 0.25. The mixing ratio (0~100 wt%) of catalyst was applied to the bed material. Air or an air-steam mixture was used as the injection gas. The SBR (steam to biomass ratio) was 0.3. The composition, tar content, and lower heating value of the generated producer gas were measured. The addition of calcined dolomite decreased tar content in the producer gas with maximum reduction of 67.3 wt%. The addition of calcined dolomite in the air gasification reduced lower heating value of the producer gas. However The addition of calcined dolomite in the air-steam gasification slightly increased its lower heating value.

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

A Glove Box for the Subsampling of Suboxic and Cold Core Sediment (아산화 및 저온의 코아 퇴적물 중 부시료 채취를 위한 글러브박스)

  • JUNG, HOI-SOO;KWEON, SOO-JAE;KIM, CHONG-KUN
    • 한국해양학회지
    • /
    • v.25 no.4
    • /
    • pp.240-244
    • /
    • 1990
  • To solve two problems, temperature shock to the man and difficulty in exchanging the air in the glove box into N2 gas, during the subsampling of Suboxic and cold core sediments, a portable glove box with a refrigerating machine and a gas exchanging bag was constructed for subsampling of sediment cores on board. The refrigerator of the glove box can cool down 200 litter air at 30$^{\circ}C$ to 2$^{\circ}C$${\pm}$2$^{\circ}C$ within 5 minutes. The box was successfully operated during the second KORDI's deep sea research cruise of 1989 in the North equatorial Pacific. Pore water data obtained from the cruise show no evidence for artifacts caused by warming up or oxidation of sediments during subsampling.

  • PDF