• Title/Summary/Keyword: 공기저항

Search Result 496, Processing Time 0.033 seconds

Oxidation Behavior of U-2wt%Nb, Ti, and Ni Alloys in Air (U-2wt%Nb, Ti, Ni 합금의 공기중 산화거동)

  • 주준식;유길성;조일제;국동학;서항석;이은표;방경식;김호동
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.395-400
    • /
    • 2003
  • For the long term storage safety study of the metallic spent fuel, U-Nb, U-Ti, U-Ni, U-Zr, and U-Hf simulated metallic uranium alloys, known as corrosion resistant alloys, were fabricated and oxidized in oxygen gas at $200^{\circ}C~300^{\circ}C$. Simulated metallic uranium alloys were more corrosion resistant than pure uranium metal, and corrosion resistance increases Nb, Ni, Ti in that order. The oxidation rates of uranium alloys determined and activation energy was calculated for each alloy. The matrix microstructure of the test specimens were analyzed using OM, SEM, and EPMA. It was concluded that Nb was the best acceptable alloying elements for reducing corrosion of uranium meta] considered to suitable as candidate.

  • PDF

A Case Study on Settlement Promotion of a Large Size Open Caisson using Air-Jet an Method (공기분사공법을 이용한 초대형 Open Caisson의 침하촉진에 대한 사례연구)

  • Jeong, Jin-Seob;Lee, Jong-Cheon;Kim, Hae-Woog;Kim, Tae-Hyung
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.227-233
    • /
    • 2009
  • This experimental study has been carried out to investigate the reduction in side friction of open caisson using air-jet method. For this study, the large size caisson having air-pockets was used. This caisson was used as substructure of bridge. By using air-jet method, settlement time was decreased and even settlement was reached to the depth which conventional methods could not be. We found that the side resistance decreases to less then half the expected value. In addition to these merits, the air-jet method can result in self-weight settlement without applying additional load. Also the open caisson damage caused by blasting can be prevented with this method.

Analysis of Air Voids System Using Image Analysis Technique in Hardened Concrete (화상분석법을 통한 경화 콘크리트의 미세 공극 구조 분석)

  • Yun Kyong-Ku;Jeong Won-Kyong;Jun In-Koo;Lee Bong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.741-750
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as freeze-thaw resistance, surface scaling resistance, and water permeability, and they have been characterized by spacing factor Linear traverse and point count methods in ASTM standard have been used in estimating an air void system in hardened concrete. However, these methods require lots of time and efforts, further they are not repeatable. Image analysis method could be utilized In estimating an air void systems in hardened concrete with a developments of microscope, digital camera and computer program. The purpose of this study was to develope image analysis method and provide a guideline by comparing the results from ASTM method and image analysis method. The concerns were at air void content and diameter distribution, air voids system as well as spacing factors. The experimental variables included air content by air entrained agent (0, 0.01, $0.03\%$) and depth of specimen (top, middle, bottom). The result showed that it was possible to calculate spacing factor using image analysis technique, as well as air content, air diameter distribution, and air structure. This study also contributed in developing an reasonable and repeatable image analysis method.

The Simultaneous Nitrification and Organics Oxidation of Wastewater in Airlift Biofilm Reactors (공기리프트 생물막 반응기에서의 폐수 질화 및 유기물 동시산화)

  • 서일순;허충희
    • KSBB Journal
    • /
    • v.16 no.6
    • /
    • pp.573-578
    • /
    • 2001
  • The effects of organic supplement (acetate) and dissolved oxygen concentration on the nitrification rate of wastewater were investigated in the 27.7 L pilot-scale airlift biofilm reactor with the granular activated carbon media of 0.613 mm diameter. The ammonium oxidation rate increased stepwise up to 5 kg N/㎥$.$d at the riser air velocity of 0.063 m/s, when the air velocity and the ammonium loading rate were raised alternately. The nitrite build-up was observed during the early stage of the biofilm formation, which disappeared after the reactor operation of 128 days. As increasing the organic loading rate, the organic oxidation rate increased up to 25.0 kg COD/㎥$.$d with the removal efficiency of 94% but the oxidation rates of ammonium and nitrite decreased. The oxidation rates of ammonium and nitrite increased with the dissolved oxygen concentrations. When the pure oxygen was sparged, the ammonium oxidation rate was almost five times higher than that with air at the same velocity.

  • PDF

Effects of Si doping on PTC Properties in $BaTiO_3$ thermistor sintered in reduced atmosphere and reoxididation ($SiO_2$ 함량에 따른 $BaTiO_3$계 써미스터의 PTC 특성 변화)

  • Baek, Seung-Gyeong;Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee;Nahm, Sahn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.157-157
    • /
    • 2009
  • $BaTiO_3$를 기본조성으로 하는 PTC 써미스터는 Curie 온도이상에서 저항이 급격히 상승하는 반도성 전자세라믹스로서 degaussing 소자, 정온 발열체, 온도센서, 전류 제한 소자 등 상업적으로 폭넓게 사용되고 있다. 본 소자는 소결온도, 소결 및 열처리 분위기, 불순물, 첨가제 등의 제조공정상의 인자들과 기공률, 결정립 크기 등이 복합적으로 작용하여 PTCR 특성이 크게 영향을 받기 때문에 제조하기에 무척 까다로운 소자로 알려져 있다. 특히 과전류 보호 소자용으로 사용하기 위해서는 상온 비저항을 크게 낮추어야 하며 이에 대한 연구가 계속 진행되고 있다. 따라서 본 연구에서는 SiO2을 0.5~10 at%로 달리한 조성으로 환원 분위기에서 소결하고 공기 중에서 재산화 처리하여 재료의 PTC 특성에 어떠한 영향을 미치는지 분석하였다. 소정의 조성을 선택하여 $1180^{\circ}C{\sim}1240^{\circ}C$에서 2시간 동안 환원분위기에서 소결하고, $800^{\circ}C$에서 1 시간 공기 중에서 재산화 처리한 후 R-T 특성을 측정하여 SiO2 함량에 따른 PTC 특성을 분석하였다. 그 결과 SiO2의 함량이 증가할수록 상온 저항은 낮아지다가 3.0 at% 이상으로 첨가할 경우 급격히 상승하는 경향을 나타내었다. 특히 SiO2를 1.0~3.0 at% 일 때 우수한 PTC 특성을 가졌다. $1180^{\circ}C$에서는 소결 밀도가 낮아 상온 비저항이 크게 높았지만, $1200^{\circ}C{\sim}1220^{\circ}C$에서는 정상 입성장이 나타나면서 일반적인 PTC 특성을 가졌지만, $1240^{\circ}C$ 이상에서는 공정 액상이 형성되어 비정상 입성장이 일어나 상온 비저항이 크게 낮아졌다. 한편 점핑비-log(Rmax/Rmin)는 SiO2 함량이 증가할수록 높아지다가 3.0 at% 이상에서는 낮아짐을 확인하였다.

  • PDF

A Study on Variable Speed Limit Considering Wind Resistance on Off-Shore Bridge (해상교량의 풍하중을 고려한 제한 속도 도출 방안)

  • Lee, Seon-Ha;Kang, Hee-Chan
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.5
    • /
    • pp.75-87
    • /
    • 2004
  • Along the seashore regions in Korea, though strong winds with very large strength are frequently witnessed, no system which can provide appropriate speed information for driving vehicle has been introduced. The driving against strong winds could be very dangerous because of the high possibility of accidents such as rollover and collision. These accidents usually resulted from driver's forced driving try even in difficult situation for steering vehicle, and sometimes overspeed without consideration of wind impact to the vehicles. To reduce accident caused by strong winds, it is important to inform drivers of appropriate driving speeds by perceiving strong winds. By setting up WIS at the main points where strong winds frequently appear and using the variable message sign(VMS) connected to the on-line whether information system, it tis possible to provide desired speed information, which can maintain vehicles' tractive force and maximum running resistance. The case study is conducted on the case of Mokpo-Big-Bridge, which is under construction at Mokpo city. The result show that in case the annual average direction of wind is South and the wind speed is over 8m/hr, the desired speed, which is required in order for vehicles running to South direction to maintain the marginal driving power, is 60km/hr. In addition, for the case of a typhoon such as Memi generated in 2003 year, if wind speed had been 18m/sec in Mokpo city at that time, the running resistance at the speed of 40km/hr is calculated as 1131N. This resistance can not be overcome at the 4th gear(1054N) level, therefore, the gear of vehicles should be reduced down to the 3rd level. In this case, the appropriate speed is 40km/h, and at this point the biggest difference between running resistance and tractive force is generated.

A numerical study on the aerodynamic characteristics of a variable geometry throttle valve(VGTV) system controlling air-flow rate (유량 제어장치인 가변스로틀밸브의 기하학적 형상변화에 따른 공기역학 특성분석 연구)

  • Cho, Hyun-Sung;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.378-383
    • /
    • 2013
  • A butterfly throttle valve has been used to control the brake power of an SI engine by controlling the mass flow-rate of intake air in the induction system. However, the valve has a serious effect on the volumetric efficiency of the engine due to the pressure resistance in the induction system. In this study, a new intake air controlling valve named "Variable Geometry Throttle Valve(VGTV)" is proposed to minimize the pressure resistance in the intake system of an SI engine. The design concept of VGTV is on the application of a venturi nozzle in the air flow path. Instead of change of the butterfly valve angle in the airflow field, the throat width of the VGTV valve is varied with the operating condition of an SI engine. In this numerical study, CFD(computational fluid dynamics) simulation technique was incorporated to have an aerodynamics performance analysis of the two air flow controlling systems; butterfly valve and VGTV and compared the results to know which system has lower pressure resistance in the air intake system. From the result, it was found that VGTV has lower pressure resistance than the butterfly valve. Especially VGTV is effective on the low and medium load operating condition of an SI engine. The averaged pressure resistance of VGTV is about 49.0% lower than the value of the conventional butterfly throttle valve.

Influence of steel fiber contents on corrosion resistance of steel reinforcement (강섬유 혼입량이 철근 부식저항성능에 미치는 영향)

  • Kim, Seong-Do;Moon, Do-Young;Lee, Gyu-Phil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.283-293
    • /
    • 2015
  • In order to evaluate corrosion resistance of steel fiber-reinforced concrete, accelerated chloride migration and surface resistivity tests were conducted. In addition air content of fresh concrete, compressive strength and water absorption were measured for investigating fundamental characteristics of concrete. Two different water-cement ratios(0.44, 0.5) and three steel fiber contents(0.25%, 0.5%, 1%) were considered as variables. Note that all specimens cast with same compaction work. As a results, corrosion resistance decreased as steel fiber contents increased regardless of water-cement ratio when the concrete was compacted with same amount of work done. However, for concrete with same steel fiber content, the lower water-cement ratio showed the better corrosion resistance. It is found that enhancement of fluidity and enough compaction should be done for corrosion resistance of SFRC.

Experimental Study on Aerodynamic Drag Characteristics by Train Bogie Shape Variation (차세대 고속열차 대차 형상에 따른 공기저항 변화에 대한 실험적 연구)

  • Kwak, Min-Ho;Lee, Yeong-Bin;Lee, Jung-Uk;Kim, Kyu-Hong;Lee, Dong-Ho;Chung, Hyoung-Seog;Jang, Young-Il;Kwon, Hyeok-Bin
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.14-19
    • /
    • 2011
  • Wind tunnel tests are performed so as to investigate the aerodynamic drag characteristics of HEMU-400x, next generation Korean high speed train. The experiments of 1/20 scaled 5-car train model are done at 30, 40, 50, 60m/s with a normal bogie, a bogie cover, and a streamlined shape. The flat plate with knife edge are installed to minimize the effect of boundary layer of wind tunnel for the train model. The aerodynamic drag reduction was more by a streamlined shape than by a bogie cover from a normal bogie. Based on the experimental results, the aerodynamic drag of HEMU-400x test train(6-car) was predicted. It is prediceted that More bogie cover could reduce more aerodynamic drag of the test train in replacement of normal bogies.

  • PDF

원자력 발전용 직교류 핀-관 열교환기의 성능 평가

  • 김정훈;배성원;김무환;허용석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.279-285
    • /
    • 1997
  • 본 연구에서는 나선형과 판형의 핀을 가진 원자력 발전소용 직교류 핀-관 열교환기의 열량을 ARI Standard-410에 따라 실험적으로 측정하여 풍속과 냉수속에 따른 열저항 및 압력 손실을 도출하는 것을 목적으로 하였으며, 이러한 시도를 통해서 실제 열교환기의 성능 평가시 필요한 기술적 자료를 축적하고자 하였다. 실험에서는 나선형 6fin/in, 8fin/1n, 10fin/in 열교환기와 판형 8fin/in 열교환기를 사용하였으며, 풍속을 0.486m/s와 2.214m/s로, 수속을 1m/s~4m/s로 하여 실험을 행하였다. 실험 결과를 통하여, 원자력 발전소의 격납 용기내의 공기조화를 위하여 사용되어 지는 열교환기의 성능 평가 방법 및 실증 능력을 확보하였으며, 풍속 증가에 따라 총괄 열전달 계수는 전체적으로 비례 증가하는 경향을 보였다. 판형이 나선형 보다 열전달 계수가 작게 나타났으며, 나선형 열교환기의 경우 fin수에 따른 변화는 크지 않았으나, 열전달 면적을 고려한 경우에는 나선형 10fin/in 열교환기가 가장 뛰어난 열교환 성능을 발휘함을 알 수 있었다. 또한, 공기측의 압력 손실은 전체적으로 전연 풍속 증가에 따라서 속도 제곱에 비례하여 증가하는 경향을 보였다.

  • PDF