• Title/Summary/Keyword: 공기저항

Search Result 495, Processing Time 0.029 seconds

Optimal Design for the Nose Shape of Commercial High-speed Train Using Function of Train Configuration (열차형상함수를 이용한 상용 고속열차 전두부 형상 최적설계)

  • Kwak, Minho;Yun, Suhwan;Park, Choonsoo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.279-288
    • /
    • 2015
  • Using the Vehicle Modeling Function, which can model various 3D nose shapes, nose shape optimization is performed to reduce the aerodynamic drag of the KTX Sancheon. 2D characteristic shapes of the KTX Sancheon nose were extracted and a base model of the KTX Sancheon was constructed for design optimization using the Vehicle Modeling Function. The design space was constructed with the base model and does not violate the shape constraints of commercial trains. Through nose shape optimization with the Broyden-Fletcher-Goldfarb-Shanno algorithm, the aerodynamic drag of the optimized shape was reduced by 6% compared to that of the base model. The longer nose and sharper edge of the optimized shape weaken the vortices behind the last car and can reduce the aerodynamic drag.

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (1) Study on Aerodynamic Resistance of Tomato Canopy through Wind Tunnel Experiment - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (1) 풍동실험을 통한 토마토 식물군의 공기저항 연구 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Lee Seung-Kee;Kwon Soon-Hong
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.289-295
    • /
    • 2006
  • A computational fluid dynamics (CFD) numerical model has been developed to effectively study the ventilation efficiency of multi-span greenhouses with internal crops. As the first step of the study, the internal plants of the CFD model had to be designed as a porous media because of the complexity of its physical shapes. In this paper, the results of the wind tunnel tests were introduced to find the aerodynamic resistance of the plant canopy. The Seogun tomato was used for this study which made significant effects on thermal and mass exchanges with the adjacent air as well as internal airflow resistance. With the main factors of wind speed, static pressure, and density of plant canopy, the aerodynamic resistance factor was statically found. It was finally found to be 0.26 which will be used later as an input data of the CFD model. Moreover, the experimental procedure of how to find the aerodynamic resistance of various plants using, wind tunnel was established through this study.

Analysis for Aerodynamic Resistance of Chrysanthemum Canopy through Wind Tunnel Test (풍동실험을 통한 국화군락의 공기유동 저항 분석)

  • Yu, In-Ho;Yun, Nam-Kyu;Cho, Myeong-Whan;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • A wind tunnel test was conducted at Protected Horticulture Experiment Station of National Horticultural Research Institute in Busan to find the aerodynamic resistance and quadratic resistance coefficient of chrysanthemum in greenhouse. The internal plants of the CFD model has been designed as a porous media because of the complexity of its physical shapes. Then the aerodynamic resistance value should be input for analyzing CFD model that crop is considered while the value varies by crops. In this study, the aerodynamic resistance value of chrysanthemum canopy was preliminarily found through wind tunnel test. The static pressure at windward increased as wind velocity and planting density increased. The static pressure at leeward decreased as wind velocity increased but was not significantly affected by planting density. The difference of static pressure between windward and leeward increased as wind velocity and planting density increased. The aerodynamic resistance value of chrysanthemum canopy was found to be 0.22 which will be used later as the input data of Fluent CFD model. When the planting distances were $9{\times}9\;cm$, $11{\times}11\;cm$, and $13{\times}13\;cm$, the quadratic resistance coefficients of porous media were found to be 2.22, 1.81, and 1.07, respectively. These values will be used later as the input data of CFX CFD model.

A Convergent Investigation on the Air flow in Driving According to a Cargo Container and the Wind Deflector (트럭 화물칸 및 윈드 디플렉터에 따른 운행중 공기흐름에 대한 융합 연구)

  • Choi, Kye-Kwang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.9
    • /
    • pp.175-180
    • /
    • 2020
  • In this study, the freight vehicles were modelled and the flow analysis on the existence or non-existence of a cargo container and the wind deflector were carried out. Based on the driving speed of 100 km/hr, at all models A, B and C, the highest flow rate was shown between 58 m/s and 59 m/s at the top of the model shape. All models A, B and C showed the highest pressure of air resistance between 652Pa and 671Pa at the front of the model geometry. The maximum pressure of model A is considered to be the smallest, with the least flow resistance to speed compared to models B and C. Therefore, it can be seen that model A has an advantageous condition for air resistance in terms of fuel costs. Unlike model B which causes the rapid flow resistance at the cargo compartment, model C can be found to flow a little more smoothly on the streamlined wind deflector. So, the flow air at a streamlined shape is considered to be more advantageous in terms of air resistance than at angular shape. By applying the research analysis result on the air flow in driving according to a cargo container and the wind deflector, it is seen that this study is adequate at the practical efficient design and aesthetic convergence.

A Study on Air Flow Analysis due to the Shape of Automotive Body (자동차 차체의 형상에 따른 공기 유동해석에 관한 연구)

  • Lee, Hyun-Chang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.2
    • /
    • pp.19-23
    • /
    • 2014
  • In this study, the air resistance is studied by using flow analysis near automotive body due to the its shape. Flow velocities of airs entering into inlet plane are two kinds of 70 km/h and 100 km/h. Air resistance in case of high speed driving(100 km/h) becomes higher than regular speed driving(70 km/h) and the resistance in case of the car with wider cross section at front side becomes higher than narrower cross section. By using this analysis result, the shape of automotive body can be effectively designed in order to reduce the air resistance.

지하공동 모델의 전기비저항 특성에 관한 실험적 연구

  • Park, Gap-Jin;Kim, Hyeon-Su;Kim, Hyeon-Seung;Song, Yeong-Su
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.93-98
    • /
    • 2009
  • Comprehension of physical properties distribution of underground cavity must be made primarily to show the clear image of the state of the cavity. A physical scale model experiment is executed assuming that underground cavity in filled with air or water of different ratio. The state of cavity wall is considered wet. Cavity model is made of agar. As a experimental result, even if the cavity wall is wet, high air and water ratio cavity shows high anomaly.

  • PDF

Aaerodynamic design of advanced concept car (고급개념 자동차의 공기역학설계)

  • 정인석;김현우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.13-24
    • /
    • 1988
  • 본 해설에서는 공기저항을 감소하기 위하여 위에서 열거한 점들을 고려한 공기역학적인 연구를 행함으로써 항력계수를 0.153까지 낮게한 Ford사의 프루우브IV 개발과 그 결과에 대하여 서술하고자 한다. 우선 일반적인 공기역학적 설계를 위한 연구에 대하여 서술하고 풍동실험을 반복한 결과로 보완된 부분에 대하여 설명한후 최종적인 차에 대한 풍동실험 결과를 서술하는 순서로 한다.

  • PDF

A Study for Aerodynamic Drag Reduction on Variable Message Sign using Flow Analysis (유동해석 기반 도로전광표지 공기저항 저감 구조 연구)

  • Lim, Se-Mi;Song, Dae-Young;Park, Kyeung-U;Park, Jun-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.140-146
    • /
    • 2011
  • As the demand of Variable Message Sign(VMS) has become pervasive in fulfilling the ITS policy, the costs of maintaining the Variable Message Sign operation have also increased. This paper proposes the U-curved figure, the C-curved figure and the ventilated figure type for aerodynamic drag reduction on Variable Message Sign and shows the analysis of aerodynamic drag effects using Flow Analysis. As a results of the flow analysis for right-angled, 45 degrees from side to side and 45 degrees from up or down, the C-curved figure and the ventilated figure type show about 30% aerodynamic drag reduction in all direction. And the U-curved figure type shows vivid aerodynamic drag reduction for right-angled and 45 degree from side to side, but trivial aerodynamic drag reduction for 45 degree from up or down. It is possible to reduce not only the damage on Variable Message Sign due to typhoon because of the aerodynamic drag reduction, but also installation constraints because of lighter Variable Message Sign support structure by appling the proposed structure and analysis in this paper.

Epidural Space Identification Device Using Air-filled Catheter (공기도관을 사용하는 경막외강 자동탐지기구)

  • 강재환;김현식;김경아;김상태;배진호;임승운;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.9-13
    • /
    • 2003
  • An assist device was developed to identify the epidural space by continously monitoring the air-filled catheter pressure. The pressure signal appropriately amplified and filtered enabled to alarm the needle introduction into the epidural space by thresholding detection. Ten LEDs provided a visual change of catheter pressure before alarming for user convenience. Clinical trials were performed in 30 patients with 83% success rate at the first trial. When failed, the second trial was enough for successful anesthesia. The air volume introduced during each anesthesia was less than 1ml, causing side effects. Air filling of the catheter could also minimize infection possibility. Therefore, the present device guarantees safe anesthesia with user convenience.