• Title/Summary/Keyword: 공극시험

Search Result 427, Processing Time 0.029 seconds

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho, Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.357-364
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. Specimen obtained 1mm thickness from the insulation of real power cable and cable joint. <중략>The partial discharges are measured to determine their time dependence for 60 minutes and the influence of applied electrical stress under 30kV. $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Evaluation of Absorbent-Pervious Alkali-Activated Block Using Recycled Aggregate (순환골재를 이용한 보투수성 알칼리 결합재 블록의 성능평가)

  • Park, Kwang-Min;Kim, Hyung-Suk;Cho, Young-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.160-167
    • /
    • 2017
  • The purpose of this study is to identify the possibility of developing the 100% Recycled-resources Absorbent-Pervious Alkali-activated Blocks using both the alkalli-binder and the recycled aggregate. In addition, It established a test method such as Void ratio, compressive strength, coefficient permeability, absorption, and evaporation. As a result, an alkali-activated using recycled aggregate block was able to manufacture an 24 MPa class absorbent-pervious blocks with a liquid type sodium silicate and early high temperature curing. In this case, water-holding capacity, absorption and relative absorption were more effective than the natural aggregates. In conclusion, Absorbent-pervious alkali-activated Block Using recycled aggregate has a surface temperature reducing effect of approximately 10 % compared to ordinary concrete block.

Effect of Carbonized Wastewoods on Soil Improvement(2) (목질폐잔재 탄화물의 토양개량 효과(2))

  • Shin, Chang-Seob;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to examine the effect of soil improvement according to the shape of charcoal and the kind of carbonized tree species. As the results, all of the seedlings of Thuja occidentalis and Aesculus turbinata grew better in the charcoal-treated soil than the non-treated soil. In case of powder charcoal, Thuja occidentalis seedlings grew up best in the soil treated with powder charcoal of Pinus koraiensis and then grew well in order of Larix leptolepis > particle board > Quercus acutissima. In case of granulated charcoal, the seedlings grew well in order of the granulated charcoal of Larix leptolepis > particle board > Pinus koraiensis. It was analyzed that the soil porosity and the organic matter content were mo re in the charcoal -treated soil than the non-treated soil also. It is inferred that because the aeration property and the absorption of organic matter were increased in the root zone, the growth of seedlings was better in the char-coal-treated soil.

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.279-286
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. <중략> $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Estimation of Air Voids of Asphalt Concrete Using Non-destructive Density Testing (비파괴 밀도시험을 통한 아스팔트 콘크리트의 공극률 추정 연구)

  • Na, Il-ho;Lee, Sung-Jin;Yoon, Ji-Hyeon;Kim, Kwang-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.111-119
    • /
    • 2018
  • The air-void is known to be one of the influencing factors for estimating long-term performance of asphalt concrete. Most of all, confirming air void or density of pavement layer is important for quality control of field compaction level of asphalt concrete pavement. In this study, a non-nuclear type non-destructive density gage (NDDG) was used to estimate compacted air-voids of asphalt pavement as a non-destructive test method. Asphalt concrete slab specimens were prepared using 6 types of asphalt mixes in laboratory (lab) for lab NDDG test. Four different base structure materials were used to find out if there were any differences due to the type of base structure materials. The actual air-voids and NDDG air-voids were measured from 6 asphalt concrete slabs. Four sections of field asphalt pavements were tested using the NDDG, and actual air voids were also measured from field cores taken from the site where the NDDG air-void was measured. From lab and field experimental tests, it was found that the air-voids obtained by NDDG were not the same as the actual air-voids measured from the asphalt concrete specimen. However, it was possible to estimate air voids based on the relationship obtained from regression analysis between actual and NDDG air voids. The predicted air-voids based on the NDDG air-voids obtained from 50mm depth were found to be reliable levels with $R^2{\fallingdotseq}0.9$. Therefore, it was concluded that the air-voids obtained from NDDG could be used to estimate actual air-voids in the field asphalt pavement with a relatively high coefficient of determination.

Changes of Soil Physico-chemical Properties by Repeated Application of Chicken and Pig Manure Compost (계분 및 돈분퇴비의 연용에 의한 토양의 물리화학성 변화)

  • Chang, Ki-woon;Cho, Sung-hyun;Kwak, Jung-ha
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.1
    • /
    • pp.23-30
    • /
    • 1999
  • The changes of soil physico-chemical properties were investigated in the sandy loam soil amended with various application rates of chicken and pig manure composts. After repeated application of the composts for 3 years, total nitrogen content in soil treated with applied 120Mg/ha of chicken and pig manure composts was 2.1 g/kg equally. Organic matter content was 38.8 and 39.1 g/kg, available phosphate content was 602 and 585 mg/kg, and cation exchange capacity(CEC) was 10.1 and 12.4 cmol/kg in chicken and pig manure compost 120 Mg/ha treatment, respectively. Exchangeable K, Ca, Na, Mg contents, and electrical conductivity(EC) increased with the amount of applied compost. Also, with increased amount of applied compost, porosity of soil increased, but hardness, bulk density and Y value decreased.

  • PDF

Partial Discharge Detection and Statistic Value Calculation of Power Cable Using Data Acquisition System (데이터 취득 시스템을 이용한 전력케이블의 부분방전 검출과 통계량 계산)

  • 조경순
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.12
    • /
    • pp.1651-1658
    • /
    • 2002
  • Recently power cable used generally in Korea, because installation is very simple and it has high stability. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Especially, fault rates are arise from impurities or voids. A suitable solution for a monitoring of power cable during the after-laying test and service is partial discharge detection. The artificial defects between cable joint(EPR) and insulator(XLPE) interface are considered in this research to investigating the partial discharge characteristics. ${\varphi}$-q-n properties were detected using data acquisition system and Maximum charge($q_{max}$), repetition rate(${\={n}$), average charge(${\={q}$), Unbalance rate of ${\={n}$ and ${\={q}$ are calculated in order to analysis partial discharge properties quantitatively from this statistic value.

  • PDF

Permeability Variation With Lift Thickness of Asphalt Pavement (아스팔트 포장의 시공 포설두께에 따른 투수계수 변화특성)

  • Park, Sang Hyun;Moon, Jun Ho;Bae, Seok Il;Kim, Young Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2229-2233
    • /
    • 2015
  • The permeability of HMA(hot mixed asphalt) is a major influencing factor for long-term performance of the pavement. Especially, the lift thickness of the pavement during construction causes a wide range of physical properties of HMA. This study investigates the correlationship between the lift thickness and the physical properties of HMA through a series of laboratory experiments. The specimens were cored from a construction site of the dense graded asphalt pavement. The cored samples have various lift thickness and the number of compaction for the study. The results of the study show that the permeability of the sample decreases with the apperant density and t/NMAS, and the air void ratio. Therefore, the commonly used construction method as a constant lift thickness regardless of conditions needs to be reconsidered.

Effect of change in forest environment on water storage capacity in soil and streamflow (산림환경 변화가 토양내 수저유능력과 유출에 미치는 영향)

  • Nam, Yi;Park, Seung-Ki
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.35-51
    • /
    • 1997
  • To clarify the effect of forest environmental changes (forest type difference and clearcut) on water storage capacity in soil and stream flow, watershed had been investigated in Pyungchang, Kangwon-Do during 1983∼1993. Hydrological datas such as runoff, monthly ratio of runoff to precipitation, runoff-duration, monthly runoff(by plenty, ordinary, low and scanty duration), total runoff, direct runoff by runoff components, bulk density, porosity, coarse pore, fine pore, permeability and effective water storage were obtained from Backokpo and Yimokjong watersheds. The monthly ratio of runoff to precipitation, runoff and runoff-duration were higher in Yimokiong than in Backokpo due to forest type difference. On compararing pre-treatment with trement period in two experimental watersheds, pre-treatment period was lower than treatment period. Physical properties of soil such as bulk density, porosity, permeability, and effective water storage capacity conditions were better during the pre-trement period than treatment period in the two experiment plots.

  • PDF

Site Assessment for the Water Purification Effect of Porous Concrete by using Effective Micro-organisms (유용미생물을 이용한 포러스콘크리트의 수질정화특성에 대한 현장평가)

  • Kim, Bong-Kyun;Park, Jun-Seok;Seo, Dae-Seuk;Kim, Wha-Jung;Kim, Yun-Yung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.109-119
    • /
    • 2015
  • In recent years, a rapid growth in the population and urbanization led to an increasing industrial growth. The inadequate treated-wasted water from industry and various non-point sources causes significant negative effects on the stream water. For past few decades, extensive researches have been performed on water purification process. The purpose of this study is to investigate mechanical performance and water purification properties of porous concrete by using effective microorganisms through the site assessment test. The mechanical performance evaluation results showed that the increase void ration caused an decrease in the strength. The optimal mix rate was found to be 15% void rate From the site assessment, it was evaluated that the porous concrete improved the quality of the water and the purification ratios are 34.1 for SS, 14.6% for BOD, 34.9% for COD, 11.4% for T-N, and 12.6% for T-P. The porous concrete and the related purification technique can reduce the non-point pollution sources flowing into the river.