The permeability of HMA(hot mixed asphalt) is a major influencing factor for long-term performance of the pavement. Especially, the lift thickness of the pavement during construction causes a wide range of physical properties of HMA. This study investigates the correlationship between the lift thickness and the physical properties of HMA through a series of laboratory experiments. The specimens were cored from a construction site of the dense graded asphalt pavement. The cored samples have various lift thickness and the number of compaction for the study. The results of the study show that the permeability of the sample decreases with the apperant density and t/NMAS, and the air void ratio. Therefore, the commonly used construction method as a constant lift thickness regardless of conditions needs to be reconsidered.

아스팔트 포장의 투수성은 포장의 장기적 공용성에 아주 큰 영향을 미친다. 특히, 시공 시 포설 두께에 따른 투수계수가 크게 변화하는 것으로 알려져 있다. 이 연구에서는 많이 사용되고 있는 밀입도 아스팔트 포장의 시공 시 포설두께에 따른 물성치와 투수계수를 실내에서 측정하여 포설두께에 따른 물성치의 상관관계를 도출하고자 하였다. 실제 포설 현장에서 직접 시편을 코어 채취하여 실내시험을 수행하였다. 포설되는 포장의 두께, 다짐횟수가 다른 위치에서 시료를 채취하였으며 각각의 조건에 따른 실험결과를 비교/분석하였다. 연구결과 겉보기밀도와 t/NMAS가 감소할수록 투수계수는 증가하였고, 공극률이 증가할수록 투수계수가 증가하는 것으로 나타났다. 따라서, 현재 사용되고 있는 일률적인 포설두께에 대한 시공법을 투수계수 변화를 고려하여 다소 조정 할 필요가 있는 것으로 나타났다.

Keywords

References

  1. Ministry of Land, Transport and Maritime Affairs, "Asphalt mixture production and installation instructions", 2009,
  2. Hwnag, S. and Rhee, S.,, "Evaluation on Laboratory Moisture Damage Characteristics of the Asphalt Mixtures using Indirect Tensile Test", Journal of the Korean Society of Civil Engineering, Vol.28 No.2, pp.24 3-248, 2008
  3. Brown, E. R., Hainin, M. R., Cooley, A., and Hurley, G, "Relationship of Air Voids, Lift Thickness, and Permeability in Hot Mix Asphalt Pavements" National Cooperative Highway Research Program, 2004
  4. Brown, E. R., Hainin, M. R., Cooley, A., and Hurley, G, "Relationship of Air Voids, Lift Thickness, and Permeability in Hot Mix Asphalt Pavements" National Cooperative Highway Research Program, 2004
  5. Cooley, L. A., Brown, E. R., and Maghsoodloo, S, "Development of Critical Field Permeability and Pavement Density Values for Coarse-Graded Superpave Pavements", National Center for Asphalt Technology, 2001
  6. Cooley, L. A., Prowell, B. D., Brown, E. R, "Issues Pertaining to the Permeability Characteristics of Coarse-Graded Superpave Mixes" National Center for Asphalt Technology, 2002