• Title/Summary/Keyword: 공간전하

Search Result 221, Processing Time 0.025 seconds

Effects of Pre-formed Space Charges by Negative DC Voltages on PD Characteristics in XLPE (부극성 직류전압에 의해 사전 형성된 공간전하가 XLPE의 부분방전특성에 미치는 영향)

  • 황보승;이준호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.310-313
    • /
    • 2003
  • The purpose of this paper is to evaluate the effects of pre-formed space charges by DC stress on partial discharge(PD) characteristics in XLPE. We have suggested a modified pulsed electro-acoustic(PEA) method and successfully measured both space charge distribution and current simultaneously. It has been demonstrated that the PD patterns are strongly influenced by the pre-formed space charge distributions, which are hardly disappeared up to AC 8㎸ in electrode configuration including air gap between XLPE layer and electrode. From the results, it could be said that the pre-formed space charges by DC stress can play harmful and dangerous roles in insulating system under AC operating voltages because of the field distortion and localization due to the pre-formed space charge.

A Study on Improvement of the Characteristics of Discharge AND Gate PDP (방전 AND Gate PDP의 특성 개선에 관한 연구)

  • Ryeom, Jeong-Duk;Son, Hyun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.24-28
    • /
    • 2004
  • 본 연구는 기존에 제안한 방전 AND gate PDP의 결점을 개선한 연구로써 AND gate를 구성하는 DC 방전의 극성을 반대로 설계하여 인접 주사전극에 대한 cross talk를 개선하였다. 또한 기존의 AND gate가 공간전하에 의한 방전의 비선형성에 의존한 것과는 달리 본 연구에서 제안한 AND gate는 방전 경로에 따른 전압의 변화에 의존하는 것으로 AND gate의 동작이 한층 안정해 졌다. 실험 결과 4개의 수평 주사전극에 대해 선택적인 어드레스 방전이 가능하였으며 각각 34V와 70V의 AND 방전 및 Data 방전의 동작마진을 얻을 수가 있었다.

  • PDF

Characteristic of Mercury free Flat fluorescent Lamp as Driving frequency (주파수 변화에 따른 무수은 평판 형광 램프의 특성)

  • Lee, Myoung-Ho;Lim, Kee-Joe;Lim, Min-Su;Lee, Mun-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2075-2078
    • /
    • 2005
  • 본 논문은 무수은 평판 형광램프의 구동원리를 해석하기 위하여 주파수 변화에 따른 벽전하와 벽전압 특성이 방전특성에 미치는 영향을 연구하였다. 펄스폭 $9[{\mu}s]$, 300[ns]의 전압 상승 시간을 갖는 펄스파로 방전시켰다. 벽전하, 정전용량, 벽전압의 전기적 특성은 인가된 전압, 전류 파형으로부터 계산하였다. 이때 구동 주파수는 20[kHz]에서 40[kHz]까지 변화시키면서 방전 전후의 정전용량 및 Q-V특성 곡선을 해석하였다. 주파수가 증가하면서 전극간의 정전용량 $C_p$ 방전공간상의 정전용량 $C_o$는 변화를 보이지 않았으나 방전공간과 전극사이의 정전용량 $2C_g$는 증가하는 경향을 보였다. 또한 주파수가 증가하면서 방전개시 전압은 감소하였으며 효율은 감소하는 경향을 보였다.

  • PDF

Prebreakdown corona processes of point-to-plane gap in $SF_6$gas ($SF_6$ 가스중에서 침-평판간극의 전구코로나 과정)

  • 이복희;백용현
    • Electrical & Electronic Materials
    • /
    • v.5 no.1
    • /
    • pp.99-110
    • /
    • 1992
  • 본 논문은 고정된 바늘모양의 공기물에 의하여 형성된 불평등전계중에서 뇌임펄스전압에 대한 SF$_{6}$가스의 절연특성과 전구방전진전에 관한 것이다. 하전입자의 이동에 의하여 외부회로에 흐르는 전도전류의 측정방법에 대하여 기술하고 0.05~0.3[MPa]의 압력범위에서 섬락전압-압력특성을 측정하였으며 분류기와 광전자증배관을 사용하여 전구방전의 순시적 진전과정을 관측하였다. 전구방전은 돌기물의 선단에서 발생한 초기스트리머에 의하여 발단되며 정극성의 경우 섬락전압은 국부고전계에 매우 민감하며 리이더메카니즘으로 진전됨이 확인되었다. 전구방전현상의 극성의존성은 공간전하의 영향이 지배적이었다. 더불어 본 연구에서 제안된 전구전류의 측정기법은 불평등전계중에서의 전자사태전류, 코로나방전과 공극내에서의 부분방전의 측정에 매우 유용하게 적용될 것이다.

  • PDF

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

Characteization of Space Charge Distribution and Conduction Current in Dielectric material With Temperature (온도에 따른 유전체내에서의 공간전하 분포와 전도전류 특성)

  • Kim, Jin-Kyun;HwangBo, Seung;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1078-1080
    • /
    • 1995
  • The pulsed electro-acoustic method was used as a nondestructive measurement technique of spare charge distribution in dielectric materials. In our work presented here, we measured simultaneously the space charge distribution and conduction current in the low-density polyethylene samples with elevated temperatures up to $80^{\circ}C$ and electric field up to 20kV/mm. In the temperature less than $50^{\circ}C$, homocharges are mainly accumulated close to the electrodes under DC bias and after grounding. At the temperature exeeds $50^{\circ}C$, heterocharges are accumulated near the opposite electrode under DC bias. However after grounding the upper electrode, this charges immediately disappeared. The conduction current in LDPE at $20^{\circ}C$ and $30^{\circ}C$ was reduced slowly with increasing interval of applied voltage. But as temperature increased, the conduction current tended to increase slowly with the time and the degree of increase is enlarged.

  • PDF

The Effect of Space Charge on the PD Pattern and Dielectric Barrier Discharge under AC (교류전압에서 PD 패턴 및 유전체 장벽 방전에 미치는 공간전하의 영향)

  • Gwon, Yun-Hyeok;Hwang, Bo-Seung;Lee, Dong-Yeong;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.4
    • /
    • pp.226-231
    • /
    • 2000
  • In this paper, we present new method to analyze the space charge effect on the electrical characteristics in polymer. It is new measurement system and analysis method that have not reported yet. By using this measurement system, we make observation to space charge accumulated on the surface of polymer at AC voltage, so it is examined to verify the correlation of space charge and partial discharge(PD). In the result of experiment, it can be known that PD pattern is related more closely to space charge accumulated on the surface of polymer than in the inner part, and applied voltage in the air is ruled by this dynamic partial discharge. Also, above critical voltage, the space charge accumulated on the surface of polymer have no effect to the magnitude of PD and the applied voltage in the air. It has been known that the electric power of the dissolution system is proportioned to the frequency and the magnitude of applied voltage, but we can know by this result of the experiment that the efficiency of the dissolution is not related to the rise of voltage above critical voltage.

  • PDF

Fabrication and Characteristics of Flat Fluorescent Lamp (평판형광램프의 제작 및 특성)

  • 권순석;임민수;임기조
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.8-12
    • /
    • 2002
  • In this paper, we studied a flat fluorescent lamp with high luminance for LCD backlighting. The lamps have simple structures with ITO glass, insulator layer, phosphor layer, electrode layer and gas gap. The firing voltage was decreased with increasing the frequency. It was considered that this tendency was resulted from the space charge effect due to Xe and Ar positive ions trapped in gas gap. Decrease of uniform voltage at higher drive frequency is due to the remaining space charges which are produced by preceding period. As a result, luminance of 2700[cd/m$^2$] and maximum luminous efficiency of 51[m/W] were obtained with luminance uniformity of 96[%] in operation(700[V$\_$rms/], 80[kHz].

A Study on the Characteristics of Floating Discharge in the AND Gate PDP (AND Gate PDP의 Floating 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.22-27
    • /
    • 2004
  • The gas discharge AND gate which have been newly proposed is applied to three electrode surface discharge AC PDP. The address discharge characteristics by the DC-AC floating discharge by which Y electrode is made floating electrode is analyzed The address discharge can be begun by using the floating discharge from the experiment result Moreover, the display discharge can be sustained. The DC priming discharge that the floating discharge is matched to timing is generated in a supplementary electrode. As a result, space charge is supplied enough to the space of the floating discharge and the data voltage is lowered up to l00(V). Driving method to use this DC-AC floating discharge is able to obtain the address operation margin of l00(V).

Effects of Space Charge on Conduction Mechanism in Low density Polyethylene with Air Gap (공기층을 가진 저밀도 폴리에틸렌에서의 전도특성과 공간전하 효과)

  • Park, H.W.;Kwon, Y.H.;Jeon, S.I.;HwangBo, S.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1438-1440
    • /
    • 1998
  • In this work, simultaneous measur of space charge and conduction current was c out in LDPE with air gap by Pulsed-Electro-Aco Method. Also, effect of long time charging at con electric field on the formation of space charge conduction was investigated. From the experim results. we knew that the homo space charge formed near the dielectric surfaces and moving the bulk of dielectric as the electric field elevated. This was related with the deep traps b carriers and de trapping by Poole-field lowering conduction current was coincident with the Pool emission. From the long time charging experimen obtained the results that the negative space was moving into the dielectric bulk as the cha continued and the positive space charge accumulated at upper surface of LDPE.

  • PDF