• Title/Summary/Keyword: 골반교정

Search Result 39, Processing Time 0.026 seconds

Exploring the Effect of Qihyul-therapy for Recovery of Qi Circulation in Body (인체에서 기혈(氣穴) 순환 회복을 위한 기혈테라피의 효과 탐색)

  • Kim, Yong Pil;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.63-70
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate whether Qihyul-therapy was effective against subjects of bad Qihyul circulation who had narrowed muscles of the buttocks, a distorted body shape, or pain. Methods: Qihyul-therapy used. Results: The muscles of the buttocks remained almost untouched. The elasticity of the muscles restored. The skin tone brightened, and the anal muscle strengthened after Qihyul-therapy. The subject's body was shifted to the right by -7°. The right arm was about 6 cm longer than the left arm. But after correction, the right arm was about 5 cm shorter. The distorted body was almost balanced. After neck and shoulder correction, the distance between the collarbone and neck was 7~10 cm wider. After the pelvic correction, the pain in the buttocks was relieved, and the position of the hip joint returned correctly. The right leg that was turned 45° to the left was corrected, and the length became the same. Subjects had no knees attached, their right knees were up 5 cm above the left, and their ankles bent at an angle of 30 ° relative to the left, but after correction, the knees of the two legs stably attached. The height of the knee became the normal angle. Conclusion: If the Qihyul-therapy, the spine correction Qihyul-exercise and the pelvic correction Qihyul-exercise performed steadily, the deformed body shape restored adequately, and it is useful to prevent and cure related diseases by alleviating the pains.

Effect of pelvic adjustment on chronic low back pain and spino-pelvic parameters in middle-aged women (골반교정이 중년 여성의 만성요통과 척추골반지표에 미치는 영향)

  • Seo, Yun-Gyo;Kim, Jaehee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.347-355
    • /
    • 2017
  • The purpose of this study was to investigate the effects of pelvic adjustment on low back pain and spino-pelvic parameters in middle-aged women. Thirty-eight middle-aged women with chronic low back pain were randomly assigned to the pelvic adjustment (n = 20) oruntreated control (n = 18) group. Pelvic adjustment interventionswereperformed four times a week for 8 weeksin the former group. At baseline and after 8 weeks, the back pain and back function were evaluated using the visual analogue scale (VAS), Oswestry disability index (ODI), and back flexibility. Additionally, the spino-pelvic radiographic parameters and serum C-reactive protein (CRP) levels were assessed. After 8 weeks, the VAS, ODI, and back flexibility significantly improved in the pelvic adjustment group compared with the control group. It was found that the changes from baseline in the lumbar lordotic angle, sacral slope, pelvic crest unleveling, and femoral head height inequality were significantly greater in the pelvic adjustment group than in the control group. There were no significant changes in the pelvic incidence or serum CRP levels in either group. In conclusion, pelvic adjustment has beneficial effects on chronic low back pain and back function, suggesting that the effects of pelvic adjustment on back pain may at least in part result from changes in the spino-pelvic alignment.

Building practical treatment protocol by comparing the effect of adjustment between Thompson Terminal Technique and Exercise in malpositioned pelvic which induces imbalance of body (골반변위에 따른 신체 불균형에 대한 톰슨터미널테크닉과 운동요법의 교정 효과비교분석을 통한 임상치료프로토콜의 구성)

  • Park, Joon-Ki;Choi, Eun-Seok;Kim, Min-Jung;Lee, Man-Su;Lee, Min-Sun
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.445-457
    • /
    • 2016
  • The purpose of the study is to provide frame work of efficient diagnostic and treatment protocol for the people with malpositioned pelvic which causes imbalance of body. Study subjects were grouped as experimental, comparison and control group. Each group consisted of five men and five women randomly assigned. Experimental group was to be tested with Thompson Terminal Technique, its corrective effect and the effect of maintaining the treatment. There were 43.01%p difference in effectiveness of the applied technique between Thompson Terminal Technique and Muscle Energy Technique. It indicates that Thompson Terminal Technique is more effective in treating pelvic misalignment than Muscle Energy Technique. As a result, the use of chiropractic and resistance exercises is proven to be effective for treating the imbalance of body. Also, to maximize the effect of treatment, it is preferable to apply Muscle Energy Technique after applying the Thompson Terminal Technique.

An Overview of Clinical Studies on Pelvic Correction in Korea (골반교정에 대한 국내 임상 연구 동향)

  • Beag, Ji You;Bae, Jae Ryong;Ahn, Hun Mo;Lee, Jae Heung
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.20 no.1
    • /
    • pp.118-147
    • /
    • 2020
  • Objective : The purpose of this study is to understand trends of pelvic correction therapy in Korea and to assist research activities on pelvic correction therapy. Also, this study selected and presented indicators for measuring pelvic slope to help ensure consistent studies with uniform indicators in future studies related to pelvic correction. Methods : The following keywords "골반", "골반 교정", "골반 변위" "Pelvic correction" were searched on three specialized search sites (RISS, NAI, DBpia). Trends in pelvic correction therapy were analyzed through the selected researches suitable among these searched researches in an overview format. Results : 1. A total of 7,806 studies were searched and a total of 268 studies were finally selected. 2. Studies began in 1977 and have been actively studied until recently, with 35 studies in 2017 being the most recent trend since 2000. 3. In the results according to the Main Field of Research, the 'Arts and Kinesiology'(113, 42.16%) and 'Medicine and Pharmacy'(103, 38.43%) were the most in order. To the Middle Field, the 'Kinesiology was the largest with 96(35.82%) studies. 4. In the results according to the study design, 'Pre-Post Test(PPT)' was the largest with 107 studies. 5. In the results according to the Intervention, 'Exercise' was the largest with 165 studies, of which 'Pilates' and 'Yoga' in 'Training' was the largest. 6. Among the evaluation method, the 'Pelvic Index' was used 146 times, followed by 'Spinal Alignment (99)', 'Other Joints (93)', and 'Kinetic Specialized Measurement Test (56)'. 7. Among the evaluation methods, the pelvic slope measurement indicators were PT (58), PH (48), Pelvic Torsion (40), Iliac Crest (38), ASIS-PSIS distance/angle (27), and Pelvic Width (I.W., I.L., S.W) (25) in order. 8. The journals that published the most researches were KJSS(Korean Alliance For Health, Physical Education, Recreation, And Dance;9), and JKPT(Korean Physical Therapy;9). Among the University, the Graduate School of Silla University published the most papers (12). 9. The author who published the most studies were Seungjin Park(3), the co-authors were Hoseong Lee, Gideok Park, Seongsu Bae(3), and the Thesis-Director Gyeongok Lee(7). Conclusions : 1. Studies on pelvic correction treatment continue to increase every year. 2. The main academic field of pelvic correction is 'Sports', 'Physical Therapy', and 'Medical Science'. 3. The most chosen research design method in the study on pelvic correction treatment was 'Pre-Post Test(PPT)', primarily as an intermediary, Pilates and yoga during exercise therapy, and then Chiropractic during handcraft were used as multiple frequencies. 4. Among the various measurement method indicators of pelvic correction previously used, multiple frequency was taken up in the order of PT, PH, Pelvic Torsion, iliac crest, ASIS-PSIS distance/angle, and pelvic width (I.W.,I.L.,S.W). Typically, measurements through "ASIS-PSIS angle" are recommended and are considered as the most rational in clinical trials.

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.

Retrospective Study on Surgical Repair of 31 Canine Pelvic Fracture Cases (골반 골절의 수술적 교정을 실시한 31두 개에서의 후향연구)

  • Lee, Seung-Hoon;Park, Sung-Su;Kang, Byung-Jae;Kim, Yong-Sun;Kim, Wan-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • The results of surgical repair for pelvic factures in 31 dogs were reviewed. Lameness and weight bearing scores were used to evaluate functional recovery of the hind limbs. Simple fracture occurred in sacroiliac joint (n = 5) and ilium (n = 3). Pelvic fractures had acetabular (n = 7) and non-acetabular fractures (n = 23). Acetabular fracture cases were composed of additional surgical treatments with femoral head and neck ostectomy (FHNO) (n = 4) and only acetabular rim fixation (n = 3). Simple fractures had more rapid initial and complete recovery times than multiple fractures. Non-acetabular fracture cases (initial recovery time: 2.7 weeks, complete recovery time: 9.1 weeks) had more rapid initial and complete recovery times than acetabular fracture cases (8.4, 12.5 weeks) (p < 0.05). In addition, the cases of additional surgical treatment with FHNO (5.3, 7 weeks) had more rapid mean recovery times than surgical treatment without FHNO (11.1, 16.3 weeks). Surgical approach with FHNO in acetabular fracture was an alternative method to treat pelvic fractures in small breed dogs.

The Effect of Pelvic Tilt on Muscle Activity of Cervical Erector Spinae & Upper Trapezius While Using a Smartphone (골반경사에 따른 스마트폰 사용이 목세움근과 위등세모근의 근활성도에 미치는 영향)

  • Song, Seong-In;Kang, Jong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.97-103
    • /
    • 2017
  • The purpose of this study was to investigate muscle activity of cervical erector spinae & upper trapezius while using a smartphone according to anterior pelvic tilt & posterior pelvic tilt in sitting position. & we also want to obtain basic data necessary for development of IoT devices. Fifteen healthy men & women aged 20-30 were enolled, After anterior pelvic tilt & posterior pelvic tilt in sitting position were adjusted, they used a smartphone for 5 minutes & EMG signal was measured simultaneously. We used median 3 minutes of measured EMG signal. The results of this study were as follows: In the sitting position, the use of smartphone in anterior pelvic tilt had significantly lower %RVC values in both cervical erector spinae (p <.001), left upper trapezius (p <.001) & right upper trapezius (p <.002) in comparison with posterior pelvic tilt. This means that anterior pelvic tilt make vertebrae maintain normal curvature & prevent forward head posture occurred while using a smartphone. It reduces loads around neck & shoulders, so that %RVC value is significantly lowered. In the future, new posture corrected IoT devices with an aspect of pelvic tilt should be developed.

A Facial Nerve Palsy Cases Managed by Yinyang Balancing Appliance (YBA) of FCST, a TMJ Therapy for the Balance of Meridian and Neurological System (턱관절자세음양교정술(FCST)의 음양균형장치를 활용한 구안와사 증례보고)

  • Kim, Yun Sang
    • Journal of TMJ Balancing Medicine
    • /
    • v.6 no.1
    • /
    • pp.5-10
    • /
    • 2016
  • Therapeutic effect of temporomandibular joint postural training by functional cerebrospinal therapy (FCST) for the balance of the meridian and neurologic system was observed in a facial palsy case. An idiopathic facial palsy case of House-Brackmann grade V was managed with FCST, combined with acupuncture and postural training of the cervical and pelvic structures. Clinical outcome measurement was performed by House-Brackmann grade and Yanagihara's scale. The patient showed positive changes in the degree of palsy and subjective symptoms within one month. Further research on the effect of FCST is expected.

  • PDF

Radiographic Evaluation and Triple Pelvic Osteotomy for the Treatment of Immature Canine Hip Dysplasia (어린 개 고관절 이형성의 방사선 평가 및 3중 골반골 절단술에 의한 치료)

  • 김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.370-375
    • /
    • 1997
  • 8개월령의 체중이 40.4kg인 로트와일러 수컷 어린개와 9개월령의 체중 34.6kg인 골 든 레트리버 수컷 어린개가 각각 2주령과 1개월령부터 파행 및 통증을 주중으로 머독대학 동물 병원에 내원 하였다. 내원 했을 때 호흡과 심박수 및 체온은 정상이었다. 일반 보행 및 신경검사 와 방사선 사진을 촬영하여 확인한 결과 양측 고관절 이형성(Hip displasia)과 퇴행성 관절질환 (Degenerative joint disease)을 확인 할 수 있었으며, 그 증상의 정도는 우측에 비하여 좌측이 더 심하게 나타냈다. 외과적 치료는 Slocum과 Devine에 의한 3중 고관절 절단술(Triple pelvic osteotomy)를 실시하였으며 특별한 외부 고정은 하지 않았다. 수술 후 5개월 동안 지켜본 결과 증 상은 매우 좋아졌으며 골반골의 완벽한 고정 유지에 따른 교정된 고관절을 확인 할 수 있었다.

  • PDF

Development of the Balance Chair for Improving Postural Control Ability & Pelvic Correction (골반교정 및 자세균형능력 증진을 위한 균형의자 개발)

  • Oh, Seung-Yong;Shin, Sun-Hye;Kang, Seung-Rok;Hong, Chul-Un;Kwon, Tae-Kyu
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.271-277
    • /
    • 2017
  • The purpose of this study was to develop a balance chair for improving pelvic correction and postural balance through postural balance training using tactile feedback by a vibration motor provided in real time according to the user's attitude. We built a body frame using mono cast(MC) Nylon, Touch thin film transistor(TFT) for user interface, a main control module using Arduino, a 9-axis acceleration sensor for user's posture determination, and a vibration module for tactile feedback. The prototype of the Balance Chair which surrounds the outside was made with cushion for sitting conformability. In order to verify the effectiveness of the postural balance training system using the built prototype, the muscle activity (% MVIC) of the left and right iliocostalis lumborum those are the main muscles of the spinal movement was measured with ten female subjects. And the balance ability before and after training was measured using Spine Balance 3D, a posture balance ability evaluation device. The muscular activities of the left and right iliocostalis lumborum showed the balance activation according to vibration feedback during exercise protocol and postural balance improved after balance exercise training using balance chair. This study could be apply to use the fundamental research for developing the various postural balance product.