• Title/Summary/Keyword: 고주파 가열

Search Result 225, Processing Time 0.027 seconds

Characteristic Analysis and Design of High Frequency Resonant Inverter(SEPP Type) using ZVS (ZVS를 이용한 고주파 공진 인버터(SEPP형)의 특성해석과 설계)

  • 민병재;노채균;김동희;김종해;문창수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.19-27
    • /
    • 1997
  • This paper has described about principle and form of proposed circuit made use of soft switching technology ZVS(Zero Voltage Switching) to reduce turn on and off loss at switching. Also, the analysis of the proposed circuit has described generally by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. Based on the characteristics value, a method of the circuit design is proposed. In addition, this paper proves the propriety of theoretical analysis in terms of the experimental waveforms. In the future, this proposed inverter shows that it can be practically used as power source system for induction cooker etc.

  • PDF

The Design of Auxiliary Power Supplies for 30kW, 95GHz Gyrotron (30kW, 95 GHz 자이로트론 구동을 위한 보조 전원장치 설계)

  • Seo, Jung-Ho;Jang, Sung-Roc;Ahn, Suk-Ho;Kim, Jong-Soo;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.347-348
    • /
    • 2015
  • 본 논문은 30kW, 95GHz 자이로트론 구동을 위한 $25kV_{max}$, $10mA_{max}$ 출력 사양의 Body Power Supply (BPS)와 $10V_{max}$, $10A_{max}$ 사양을 가지며 50kV 절연이 요구되는 Heater Power Supply (HPS)의 설계에 관하여 기술한다. 자이로트론 구동 효율 향상에 필요한 BPS는 높은 승압비 달성 및 절연에 대한 신뢰성 확보를 위해 8개의 분리된 코어를 사용하여 변압기를 구성하고, 각 코어간의 보상권선을 이용하는 방식을 제안하여 직렬로 구성된 8개의 고전압 정류부 간의 전압 불균형 문제를 해결 한다. HPS는 50kV 전위가 인가되는 코일 가열을 위해 사용되는 전원으로 내부 고주파 변압기를 이용하여 효율적인 절연 설계를 구현한다. 30kW, 95GHz 자이로트론 구동 시스템의 신뢰성 확보와 전원장치의 높은 전력밀도 달성을 위해 두 전원장치는 공진형 컨버터 토폴로지를 기반으로 설계하고, 시뮬레이션 및 실험을 통해 개발된 전원의 우수성을 검증한다.

  • PDF

Development of Global Simulator of $O_2$ Discharge in High Density Transformer Coupled Plasma Source (고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터 제작)

  • Kim, Hyung-Yong;Yoon, Nam-Sik;Kwon, Deuk-Chul;Kim, Jeong-Hyung;Jeong, Kwang-Hwa;Sin, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.550-551
    • /
    • 2005
  • 고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터를 제작하였다. 제작된 시뮬레이터는 $O_2$ 플라즈마 방전에서 발생되는 전자, 양이온, 음이온 및 중성종, 활성종들에 대해 공간 평균된 유체 방정식을 기반으로 하고 있으며, 고밀도 유도결합 플라즈마 장치에서 전자가열 모델은 anomalous skin effect 를 고려한 파워 흡수 모델을 적용하여 전자가 흡수하는 고주파 파워량을 결정하였다. 완성된 시뮬레이터에서 RF- 파워, gas-inlet, pumping-speed등의 조정 변수를 비롯한 여러 가지 장치 변수들의 변화에 대한 하전입자, 중성종, 활성종들의 밀도 변화 및 전자 온도 의존성을 계산하였다.

  • PDF

An Optimum Design of Pipe Bending Process Using High Frequency Induction Heating and Dynamic Reverse Moment (고주파 유도가열 및 동적 반력 모멘트를 이용한 파이프 벤딩 공정의 최적설계)

  • Lee, H.W.;Jung, S.Y.;Woo, T.K.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.19 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • The Pipe bending process using high frequency local induction heating is an advanced technique to bend pipes with a small bending radius and a large diameter. Even though the pipe bending process is a quite widespread engineering practice, it depends heavily upon trial and error method by field engineers with several years of experience. So it is necessary to develop an integrated methodology for optimum design of the pipe bending process. During hot pipe bending using induction heating, outward wall thickness of a pipe is thinned due to tensile stress and the reduction of wall thickness is not allowed to exceed 12.5%. Taguchi method and dynamic reverse moment is proposed to maintain a reduction ratio of thickness within 12.5%, when D/t ratio is high. An application of the proposed approach was compared with those of the finite element analysis and has good in agreements.

Thermal treatments effects on the properties of zinc tin oxide transparent thin film transistors (Zinc tin oxide 투명박막트랜지스터의 특성에 미치는 열처리 효과)

  • Ma, Tae Young
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.375-379
    • /
    • 2019
  • $ZnO-SnO_2(ZTO)$ was deposited by RF magnetron sputtering using a ceramic target whose Zn atomic ratio to Sn is 2:1 as a target, and the crystal structure variation with thermal treats was investigated. Transparent thin film transistors (TTFT) were fabricated using the ZTO films as active layers. About 100 nm-thick $Si_3N_4$ film grown on 100 nm-thick $SiO_2$ film was adopted as gate dielectrics. The mobility, threshold voltage, $I_{on}/I_{off}$, and interface trap density were obtained from the transfer characteristics of ZTO TTFTs. The effects of substrate temperature, and post-annealing on the property variation of ZTO TTFT were analyzed.

Estimation Error and Reliability of Measuring Unit Water Content Test Methods for Fresh Concrete Depending on Mix Design Factors at the Laboratory Level (실험실 수준에서 배합변수별 굳지 않은 콘크리트 단위수량 실험방법의 추정오차 및 신뢰성 검토)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • In this study, water content tests were performed on various fresh concretes subjected to different binder compostions to review the estimation errors and reliability of water content test methods. Micro-oven drying method, air-meter method, capacitance method and microwave penetration method were used to estimate water content of fresh concrete. Errors in water content estimation were analyzed by each test method. Regardless of the test method of water content, the estimation error was less than 5 %, and in the case of the test using mortar, the error in the estimation value was relatively large. In addition, based on the test results of water content of various concrete, the probability density function in which the estimation error for each test method becomes the population was analyzed. Water content test methods of fresh concrete which using concrete samples showed high estimate reliability of 97 % within the estimation error range of ± 10 kg/m3. On the other hand, the reliability of water content test method using mortar samples was lower.

붕화금속 나노입자 합성을 위한 RF 열플라즈마 시스템의 전산해석

  • O, Jeong-Hwan;Choe, Su-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.359.2-359.2
    • /
    • 2016
  • 붕소의 높은 융점과 비점으로 인하여 일반적인 합성법으로는 제조가 어려운 붕화금속 나노물질을 효과적으로 합성하기 위하여 열플라즈마의 특성을 전산해석 하였다. RF (Ratio Frequency, 고주파) 열플라즈마 발생기는 일반적인 직류 열플라즈마 발생기와 비교해 볼 때, 전극 침식에 의한 수명 문제나 불순물의 오염 없이 고온의 열플라즈마를 안정적으로 발생시킬 수 있기 때문에 고순도의 나노입자 합성공정에 좋은 조건을 가지고 있다. 그러나 열플라즈마의 고온 부분은 10,000 K 이상의 높은 온도를 가지고 있기 때문에 직접적인 측정으로는 나노입자 합성에 최적의 조건을 찾기가 어렵고, 전산해석을 통하여 여러 변수들에 대한 열플라즈마의 특성을 분석하여야 한다. 해석조건으로 RF 플라즈마의 입력전력은 25 kW로 고정하고 발생기 직경 20~35 mm, 유도코일 감은 수 4~6 회, 첫 번째 코일으로 부터 분말 주입구까지의 길이 10~30 mm, 방전 기체 유량 30~70 L/min에 대한 변수들에 대하여 붕화금속 나노입자 합성에 최적의 조건을 가진 RF 플라즈마의 온도 및 속도분포를 파악하였다. 전산모사 결과 RF 열플라즈마 발생기의 직경 25 mm, 분말주입구 까지의 길이 10 mm, 유도코일 감은 수 6 회, 방전 기체 유량 50 L/min 일 때, 고온영역이 중심부에 넓게 분포하여 붕화금속 나노입자를 합성하는데 최적의 조건이라 파악되었다. 방전 기체 유량 증가에 따라 고온영역의 중심부 분포를 넓게 할 수 있었으나 유량이 증가할수록 플라즈마 속도가 증가하여 붕소를 기화시키기 위한 가열시간이 짧아지므로 방전기체 유량을 조절하여 적절한 속도를 가진 플라즈마를 발생시켜야 한다. 그리고 코일의 감은 수가 증가할수록 10,000 K 이상 고온영역이 출구 쪽으로 확장되어 붕화금속 나노입자를 합성하는데 좋은 조건이 형성되었다. 본 전산해석 결과를 바탕으로 붕화금속 나노입자를 합성하는 RF 플라즈마 발생장치의 설계 및 운전조건을 적용하여 실험과의 비교연구를 통해 붕화금속 나노입자의 합성공정을 최적화 시킬 수 있다.

  • PDF

Mechanical Properties and Fabrication of Nanostructured ReSi1.75 by High Frequency Induction Heated Combustion Synthesis (고주파유도가열 연소합성에 의한 나노구조 ReSi1.75 제조 및 기계적 성질)

  • Kim, Byung-Ryang;Kim, Su-Chul;Shon, In-Jin
    • Journal of Powder Materials
    • /
    • v.16 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • Nanostructured $ReSi_{1.75}$ was synthesized to have high density via rapid and cost effective process named as high-frequency induction heated combustion synthesis(HFIHCS) method. For the process, mechanically activated Re-Si powder was used, which had been prepared by mechanical ball milling of Re and Si powders with mixing ratio of 1:1.75. Both combustion synthesis and densification were accomplished simultaneously by applying electric current and mechanical pressure of 80 MPa during the process. The average grain size, hardness, and fracture toughness of the compound were 210 nm, 1085 $kg/mm^2$ and 4 $MPa{\cdot}m^{1/2}$, respectively. The experimental results show that HFIHCS is a promising process for synthesis of nanostructured $ReSi_{1.75}$ which has a potential for both high temperature and thermo-electric applications.

Fabrication of 4.25 Co0.53Fe0.47-Al2O3 Composite by High Frequency Induction Heated Combustion Synthesis (고주파유도가열 연소합성에 의한 4.25 Co0.53Fe0.47-Al2O3 복합재료 제조)

  • Park, Na-Ra;NamKung, Hoon;Ko, In-Yong;Shon, In-Jin
    • Journal of Powder Materials
    • /
    • v.16 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • Nanopowders of $Co_3O_4$ and FeAl were fabricated by high energy ball milling. Dense 4.25 $Co_{0.53}Fe_{0.47}-Al_2O_3$ composite was simultaneously synthesized and consolidated by high frequency induction heated combustion method within 2 min from mechanically activated powders. Consolidation was accomplished under the combined effects of a induced current and mechanical pressure of 80 MPa.

Fabrication and Mechanical Properties of Dense WSi2-20vol.%SiC Composite by High-Frequency Induction-Heated Combustion Synthesis (고주파유도가열 연소합성에 의한 치밀한 WSi2-20vol.%SiC 복합재료 제조 및 기계적 특성)

  • Oh, Dong-Young;Kim, Hwan-Cheol;Lee, Sang-Kwon;Shon, In-Jin
    • Journal of Powder Materials
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2005
  • Dense $WSi_2$-20vol.%SiC composite was synthesized by high-frequency induction-heated combustion synthesis(HFIHCS) method within 2 minutes in one step from elemental powder mixture of W, Si and C. Simultaneous combustion synthesis and densification were accomplished under the combined effects of an induced current and mechanical pressure. Highly dense $WSi_2$-20vol.%SiC with relative density of up to 97% was produced under simultaneous application of 60MPa pressure and the induced current. The average grain size of $WSi_2$ was about $5.2{\mu}m$. The hardness and fracture toughness values obtained were 1700kg/$mm^2$ and $4.4MPa{\cdot}m^{1/2}$, respectively.