• Title/Summary/Keyword: 고조파 왜곡

Search Result 170, Processing Time 0.034 seconds

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.

Evaluation of Micro Crack Using Nonlinear Acoustic Effect (초음파의 비선형 특성을 이용한 미세균열 평가)

  • Lee, Tae-Hun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.352-357
    • /
    • 2008
  • The detection of micro cracks in materials at the early stage of fracture is important in many structural safety assurance problems. The nonlinear ultrasonic technique (NUT) has been considered as a positive method for this, since it is more sensitive to micro crack than conventional linear ultrasonic methods. The basic principle is that the waveform is distorted by nonlinear stress-displacement relationship on the crack interface when the ultrasonic wave transmits through, and resultantly higher order harmonics are generated. This phenomenon is called the contact acoustic nonlinearity (CAN). The purpose of this paper is to prove the applicability of CAN experimentally by detection of micro fatigue crack artificailly initiated in Aluminum specimen. For this, we prepared fatigue specimens of Al6061 material with V-notch to initiate the crack, and the amplitude of second order harmonic was measured by scanning along the crack direction. From the results, we could see that the harmonic amplitude had good correlation with COD and it can be used to detect the crack depth in more accurately than the common 6 dB drop echo method.

A study on the THD reduction of single phase 2 level inverter for grid connection for ship (선박 계통연계형 단상 2레벨 인버터의 THD 저감에 관한 연구)

  • Kim, Jung-Hoon;Kim, Sung-Hwan;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.64-69
    • /
    • 2014
  • There are 440V and 220V electric source in ship. A 440V source is used to drive the power system such as crane and winch on deck and pump in engine room, and a 220V source is used to drive the power source for residential zones, control devices in engine room. In this paper, we made single phase inverter system for grid connection with 220V source for ship, and analyzed THD(Total harmonic distortion) by variation of parameters of L-C low pass filter and deadtime of inverter switching.

Actual Conditions of Voltage and Current Harmonics on Low-voltage Power Systems Supplying Various Facilities (각종 시설물 전원계통의 전압과 전류고조파 실태)

  • Lee, Bok-Hee;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.62-70
    • /
    • 2005
  • This paper presents the actual conditions and reform measures of voltage and current harmonics being made in low-voltage power systems supplying various loads. The measurements were carried out at the secondary output terminals of 22.9[kV]/380[V]220[V] customer's transformers, and the results were discussed on the basis of the comparison with IEEE and IEC harmonics control standards. The voltage THDs of the power systems employed in this survey were less than $5[\%]$ that is considered to be acceptable. On the contrary, the current distortions were significantly greater than the voltage distortions, and the current THDs were distributed over the wide-range from 15.7 to $60.4[\%]$. In particular, the current distortion on the low voltage power lines of office buildings in which many PC and fluorescent lamps are used is remarkably more serious than that of factory facilities. As a result, the voltage distortion factors are observed within the range of its allowable level or less than the limits, but the current distortion factors are significantly greater than the limits of IEEE and IEC standards.

Computation of Distortion Power Using Complex THD (THD의 복소 성분을 이용한 고조파 왜곡 환경에서의 전력 계산)

  • 최종욱;장길수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.389-396
    • /
    • 2004
  • This paper introduces a new algorithm to calculate distortion power using complex THD(Total Harmonic Distortion) index. The proposed algorithm involves FFT(Fast Fourier Transform) to compute real and imaginary THDs of voltage and current. Case studies are presented to show the availability of the proposed method.

A Study of Deadtime Effect and Compensation Algorithm on MMC System (MMC 시스템에서 데드타임의 영향과 보상 기법 연구)

  • Seo, In Kyo;Lee, Kwang Hae;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.102-103
    • /
    • 2017
  • 본 논문에서는 MMC 시스템에서 데드타임에 의한 전압 왜곡현상을 수식적으로 분석하여 발생하는 고조파 성분을 보상하는 새로운 데드타임 보상기법을 제안한다. 알고리즘은 시뮬레이션으로 그 타당성을 검증하였다.

  • PDF

An optimal operation algorithm for implementation of digital protection relay (디지털 보호계전기 구현을 위한 최적 연산 알고리즘)

  • Kim, D.H.;Seo, J.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.259-261
    • /
    • 2003
  • 오늘날 상용화되어 있는 디지털 주파수 계전기는 교차된 시스템 전압의 양단이 0 으로 되는 동안의 시간을 측정하여 주파수를 얻는다. 이러한 계전기의 동작은 왜곡된 고조파와 노이즈로 인하여 주파수 측정을 잘못하는데 이로 인해 zoro crossing이 변하거나 증가된 zero crossing이 생성된다. 최근 몇몇의 디지털 주파수 계전기 알고리즘이 제안되었다. 본 논문에서도 역시 보다 정확하면서 고속데이터 처리가 가능하도록 보호 계전기 연산에 사용되는 알고리즘을 최적화하고자 한다.

  • PDF

Sigma-Delta Modulator for Automotive Radar Systems (차량 레이더 시스템용 시그마-델타 변조기)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.818-821
    • /
    • 2010
  • 본 논문에서는 차량 레이더 시스템용 시그마-델타 변조기를 제안한다. 개발된 변조기는 차량 레이더 시스템에서 고주파 대역 신호의 고해상도 데이터 변환, 즉 아날로그-디지털변환을 수행하는데 사용되며 저전압 및 저 왜곡 특성을 가진 몸체효과 보상형 스위치 구조로 구현되어 있다. 제안된 변조기는 0.25 마이크론 이중 폴리 3-금속 표준 CMOS 공정으로 제작되었고, $1.9{\times}1.5mm^2$의 다이 면적을 점유한다. 제안된 회로는 2.7V의 동작 전압에서 기존의 부트스트랩형 회로보다 약 20dB 향상된 우수한 총 고조파 왜곡 특성을 보였다.

  • PDF

A Study of Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-Phase Grid-connected Converters (단상 계통연계형 컨버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Seong, Eui-Seok;Jeong, Byeong-Guk;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.451-452
    • /
    • 2014
  • 본 논문에서는 단상 계통연계형 컨버터의 전원 위상각을 추종함에 있어 필수적인 전압 센서의 옵셋 오차에 대한 영향을 분석하고 이를 검출 및 보상하기 위한 알고리즘을 제안하였다. 전원전압 측정에 따른 옵셋 오차는 전원 주파수의 1배 맥동을 야기하여 전원 위상각이 왜곡된다. 왜곡된 전원 위상각에 의한 좌표변환시 동기 좌표계 dq축 전류에 전원 주파수 1배의 맥동을 야기하며 이는 계통측 상전류에 직류성분과 전원 주파수 2배의 고조파 성분을 발생시키게 된다. 따라서, 본 논문에서는 전원측정시 야기되는 옵셋 오차의 영향을 분석하고 이의 검출신호로 전원 위상각 제어기의 적분출력을 선정하였다. 또한 RMS(Root Mean Square) 기법을 이용하여 옵셋 성분을 검출 및 보상하는 알고리즘을 제안하였다. 제안된 알고리즘의 성능은 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

Frequency Detection Algorithm related Variable Data Sampling and Noise (가변 데이터 샘플링과 잡음을 고려한 주파수 추적 알고리즘)

  • Lim, Young-Bin;Ham, Sung-Sik;Shin, Chul-Ho;Kim, Young- Geun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.223-224
    • /
    • 2015
  • 배전 계통 산업 현장에서는 스위칭 소자 및 제어장치, 전 자기기들이 한 대 맞물려 증가하고 있다. 또한, 스마트 그리드(Smart Grid) 및 마이크로 그리드(Micro Grid)의 개념이 도입되면서 분산 전원 이 널리 보급되고 있다. 이로 인해 현장에서는 많은 전기전자기기들이 설치되어 운영 중에 있고, 이것은 noise 및 고조파와 같은 왜란이 발생 되는 원인을 초래하고 있다. 왜란은 여러 전기 전자 장비들의 데이터 취득 왜곡 현상을 발생시키고, 이러한 데이터 손실로 인해 기기들의 오동작 및 사고를 발생시킨다. 대표적인 왜란으로는 common mode noise 같은 대지(大地) 등의 기준점과 각 신호선 사이에 나타나는 노이즈가 있으며, 선로 및 장비 특성에 따라 기수 및 우수 고조파가 있다. 이러한 왜란들은 전자기기들의 오동작 및 신호의 부 정확성으로 제품 신뢰성에 문제를 초래한다. 특히 데이터 계측 실패 및 Serial 통신을 함에 있어서 신호 손실을 발생시켜 데이터 변형을 초래한다. 이로 인해 배전선로에 위치한 전자기기들이 왜곡된 데이터로 동작을 하게 되고 이는 곧 선로의 사고를 발생시키게 된다. 따라서 왜란들을 사전에 방지하여 기기 오동작 및 부동작을 예방하기 위해서 산업계에서는 왜란에 대한 인식을 지속적으로 증가시키고 있다. 실제 현장에서도 이와 같은 왜란으로 인해 기기 오동작을 하는 경우가 많으며 이를 해결하기 위한 여러 신호처리 기법을 적용하고 있다. 이에 본 논문에서는 여러 종류의 샘플링 데이터 량을 생성할 수 있도록 샘플링 속도를 다변환(Multi-interchange)하고 각 샘플링 속도에 맞게 계측된 샘플링 데이터를 DFT 신호 처리하여 왜란으로부터 강건한 계통 주파수를 계측한다. 또한, 주파수 별 DFT 값을 Table화 하여 계통 주파수를 찾아낸다.

  • PDF