Browse > Article
http://dx.doi.org/10.5916/jkosme.2014.38.1.64

A study on the THD reduction of single phase 2 level inverter for grid connection for ship  

Kim, Jung-Hoon (CNC Department, CSCAM)
Kim, Sung-Hwan (Division of Marine System Engineering, Korea maritime and Ocean University)
Lee, Sung-Geun (Division of Electrical and Electronics Engineering, Korea maritime and Ocean University)
Abstract
There are 440V and 220V electric source in ship. A 440V source is used to drive the power system such as crane and winch on deck and pump in engine room, and a 220V source is used to drive the power source for residential zones, control devices in engine room. In this paper, we made single phase inverter system for grid connection with 220V source for ship, and analyzed THD(Total harmonic distortion) by variation of parameters of L-C low pass filter and deadtime of inverter switching.
Keywords
Grid-connection; Inverter system; Total harmonic distortion;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. H. Kim, J. H. Kim, Y. S. Kim, and S. G. Lee, "Development power converter and monitoring system for ship's grid connection", Proceedings of the Korean Society of Marine Engineers Conference, pp. 81-81, 2011 (in Korean).
2 J. C. Baek, TMS320F28X CPU Handbook, Syncworks, 2006 (in Korean).
3 J. C. Baek, DSP Hardware Design using TMS320C24 Series, Syncworks, 2005 (in Korean).
4 BIN WU, High-Power Converters and AC Drives, Willy inter Science, pp. 95-157, 2006.
5 E. C. Nho, G. B. Joung, and N. S. Choi, Power Electronics, Munundang. pp. 370-386, 2000 (in Korean).
6 K. J. Lee, N. J. Park, and D. S. Hyun, "Design of an LCL filter employing a symmetric geometry and its control in grid-connected inverter applications", Power Electronics Annual Conference, pp. 250-252, 2008 (in Korean).   과학기술학회마을
7 H. M. Oh, S. W. Choi, and S. J. Yoon, "Control method of utility interactive PCS considering voltage quality of critical load", Power Electronics Annual Conference, pp. 175-176, 2011 (in Korean).
8 J. H. Kim, J. H. Kim, H. S. Choi, K. D. Park, Y. S. Kim, and S. G. Lee, "Improvement of output characteristics of power conversion system for ship's grid connection", Proceedings of the Korean Society of Marine Engineers Conference, pp. 81-81, 2012 (in Korean).