• Title/Summary/Keyword: 고정장치

Search Result 1,228, Processing Time 0.044 seconds

The Development of Fixing Equipment of the Unit Module Using the Probability Distribution of Transporting Load (운반하중의 확률분포를 활용한 유닛모듈 운반용 고정장치 개발)

  • Park, Nam-Cheon;Kim, Seok;Kim, Kyoon-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4267-4275
    • /
    • 2015
  • Prefabricated houses are fabricated at the factory for approximately 60 to 80% of the entire construction process, and assembled in the field. In the process of transporting and lifting, internal and external finishes of the unit module are concerned about damages. The purpose of this study is to improve the fixing equipment by analyzing load behavior. The improved fixing equipment would minimize the deformation of internal and external finishes. In order to develop the improved fixing equipment, transporting load on the fixing equipment is analyzed using Monte Carlo simulations, and structural performance is verified by the non-linear finite element analysis. Statistical analysis shows load distribution of unit module is similar with extreme value distribution. Based on the statistical analysis and Monte Carlo simulation, the maximum transporting load is 28.9kN and 95% confidence interval of transporting load is -1.22kN to 9.5kN. The nonlinear structural analysis shows improved fixing equipment is not destructed to the limit load of 35.3kN and withstands the load-bearing in the 95% confidence interval of transporting load.

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

골절의 외골격 고정

  • 박성민
    • Journal of the korean veterinary medical association
    • /
    • v.36 no.8
    • /
    • pp.700-705
    • /
    • 2000
  • 외골격 고정법은 이미 외국에서는 골절의 고정, 관절의 일시적 또는 영구적인 고정, 골격 이상 교정 등에 널리 사용되고 있다. 그럼에도 불구하고 국내에서는 소수의 수의사를 제외하고는 별로 사용되고 있지 않아 외골격 고정 장치에 관해 소개해 드리고자 한다.

  • PDF

A comparative analysis of load behavior of the fixing equipments for transporting unit modules (유닛모듈 운반용 고정장치의 하중거동 비교 분석)

  • Kim, Kyoon-tai;Kim, Seok;Jun, Young-Hun;Kim, Tae-Yeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.146-147
    • /
    • 2015
  • This paper compares load behavior of two fixing equipments for transporting unit modules. The suggested fixing equipment shows higher limit load than an existing fixing equipment, which proves that the suggested fixing equipment have higher safety.

  • PDF

Use of Cross Pins and Temporal External Skeletal Fixator for Stabilization of a Tibial Physeal Fracture in a Korean Native Calf (한우 송아지의 정강뼈 성장판 골절에서의 교차핀과 임시 외부 골격 고정장치의 이용)

  • Heo, Su-Young;Kim, Eun-Ju;Kim, Min-Su;Lee, Ki-Chang;Kim, Nam-Soo;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2012
  • A one-month-old, male Hanwoo calf was presented to Chonbuk Animal Medical Center with non-weight bearing lameness on its right hindlimb. The radiograph and CT scan showed a Salter-Harris III fracture at the distal tibia. Following open reduction, the fracture was stabilized by cross-pins. A temporal external skeletal fixator was used as an additional support for 5 weeks. 5 weeks after surgery, bone fracture had successfully healed with no complication. At 2 years after surgery, the calf could walk almost normally although intermittent weight-bearing lameness after active exercise. This is a rare case that the combined use of temporal external fixation and cross-pins fixation was sufficiently effective for treating a distal tibial physeal fracture in a calf.

Long-term effects of chlorhexidine varnish treatment on microbial changes of dental plaque in orthodontic patients with fixed appliances (Chlorhexidine varnish 처치 후 고정식 교정장치 장착 환자의 치태내 균주 변화 양상에 대한 장기간 관찰 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.335-342
    • /
    • 2000
  • The authors observed the long term effects of chlorhexidine varnish treatment on microbial change of dental plaque in orthodontic patients with fixed appliances. The initial sample was 100 patients who were arranged to be treated with fixed orthodontic appliances. The final sample consisted of 21 patients who could be traced for 32 weeks after application of fixed orthodontic appliances. They were classified into the experimental group (12 patients) and the control group (9 patients). The experimental group was treated with chlorhexidine varnish once a week for 4 weeks before application of fixed orthodontic appliance. The control group was not treated with chlorhexidine varnish before application of fixed orthodontic appliance. The experimental group was treated once more after 20 weeks. The microbial changes of dental plaque were analysed by indirect immunofluorescence technique at pre-treatment, post-treatment 4, 8, 20, and 32 weeks. The results were as follows. 1. In the experimental group, streptococus mutans was significantly suppressed during experimental period. (p<0.01) But, in the control group, streptococcus mutans was significantly increased after placement of fixed orthodontic appliances during experiment period. (p<0.05) 2. Streptococcus sanguis, Streptococcus mitis, Actinomyces viscosus, md Actinomyces naeslundii did not show significant change between the experimental and the control group during experiment period. So, if we treat the orthodontic patients with chlorhexidine varnish before application of fixed appliances, we may suppress the major cariogenic bacteria, Streptococcus mutans, selectively for long period.

  • PDF

High Efficiency Output Filter Design and Application for High Accuracy and High Stable Switching Type MPS (고정밀, 고안정 스위칭 전자석 전원장치를 위한 고효율 출력필터의 설계 및 응용)

  • Kim, S.C.;Ha, K.M.;Huang, J.Y.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.998-999
    • /
    • 2006
  • 포항가속기 연구소의 선형가속기에는 22개의 솔레노이드 전자석, 16개의 사극전자석 그리고 전자빔의 궤도 조절을 위한 16개의 2극 전자석이 있다. 선형가속기의 빔을 저장링으로 공급해주는 빔 전송선에는 22개의 사극전자석과 13개의 빔 궤도 조절용 이극 전자석이 있다. 전자빔의 정밀 제어를 위하여 전자석의 전원장치는 출력전류 분해능은 16bit 이상이고 출력전류의 안정도는 최대출력에 대하여 ${\pm}50ppm$ 이하의 고정밀 고안정도가 요구된다. 이를 위하여 풀-브릿지 4상한 DC/DC 컨버터를 이용한 전자석전원장치를 개발 하였다. 전원장치의 입력전압 직류 40V이고 출력전류는 단방향 전원장치는 최대 50A/50V 이고 양방향 전원장치는 ${\pm}20A/20V$이다. 스위칭 주파수는 50 kHz이다. 전원장치의 출력부에 필터가 없으면 출력전류에는 스윗칭과 관련된 주파수 성분이 포함 되고 전자빔은 이들 주파수 성분에 대하여 영향을 받게 된다. 이러한 이유로 출력 필터의 cut-off 주파수는 5 kHz 이하가 되어야 한다. 본 논문에서는 고정밀 고안정 스윗칭 전자석전원장치를 위한 출력필터의 설계, 제작 그리고 이를 적용한 전자석전원장치에 대하여 논의 하고자 한다.

  • PDF

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Frequency Relay for a Power System Using the Digital Phase Locked Loop (디지털 위상 고정 루프를 이용한 계전기용 주파수 측정 장치)

  • Yoon, Young-Seok;Choi, Il-Heung;Lee, Sang-Yoon;Hwang, Dong-Hwan;Lee, Sang-Jeong;Jang, Su-Hyeong;Lee, Byung-Jin;Park, Jang-Soo;Jeong, Yeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.564-566
    • /
    • 2003
  • 전력 계통에서 안정한 전력을 공급하는 것은 매우 중요하다. 전력 계통의 오류는 전압 및 주파수를 감시함으로써 검출 가능하다. 본 논문에서는 디지털 위상 고정 루프를 이용한 전력 계통의 주파수 측정 장치를 제안하고 이를 구현한 결과를 제시하고자 한다. 제안한 주파수 측정 장치는 위상 고정 루프의 기본요소로 구성된다. 위상분별기는 배타적 논리연산을 통해 위상오차를 검출하고 위상의 앞섬 및 뒤짐의 검출이 가능하도록 설계하였으며, 전력 계통의 주파수 동특성을 고려해서 3차의 루프 필터를 설계하였다. DCO는 출력 주파수의 분해능을 고려하여 입력 신호를 정확하게 추정할 수 있도록 설계하였다. 제안한 주파수 측정 장치의 성능을 검증하기 위하여 모의실험을 통해 주파수 변동량의 측정 범위 및 정확도를 검토하였으며, FPGA와 CPU를 포함하는 하드웨어를 구현하였다. FPGA에는 Verilog HDL로 디지털 위상 고정 루프의 위상분별기와 DCO를 구현하였으며 루프필터는 소프트웨어로 구현하였다. 제안한 디지털 위상 고정 루프의 성능 검증을 위해 정밀한 함수 발생기의 출력을 인가한 후 출력 주파수를 측정한 결과 및 전력 계통에 대한 실험 결과를 제시하였다.

  • PDF

Structural Safety Evaluation for Fixed CO2 Extinguishing Systems Under Ship Motion (선박모션에 따른 고정식 CO2소화 장치 구조안전성 평가)

  • Kim, Seung Chan;Kang, Sang Hoon;Choi, Joo Hyoung;Kim, Jeong-Hwan;Park, Young Chul
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.75-83
    • /
    • 2016
  • Since fire is one of the most dangerous threats to the safety of the ship, from the safety device is installed on the vessel the digestive apparatus can be viewed as the most important safety device. The fire-extinguishing device to be mounted to the vessel structure affected the stability of the structure in accordance with the blue of the sea. In particular, the Rack part of the basic safety of a fixed fire extinguishing system in the absence of a $CO_2$ container. In this paper, by utilizing simulation techniques to apply the pressure data being ejected in each direction by ship motion and $CO_2$ containers Rack perform an analysis of the structural safety assessment was part of the digestive system accordingly.