A Practical Procedure for the Design Optimization of Pile-type Substructure in a Mooring Dolphin (계류돌핀의 말뚝형 하부구조에 대한 실용적 설계 최적화 과정)

  • Ryu, Yeon-Sun;Lee, Nary;Kim, Jeong-Tae;Cho, Hyun-Ma
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.285-294
    • /
    • 2000
  • In this paper, a practical procedure for the design optimization of tubular-steel-pile-type substructure in a mooring dolphin is investigated and numerically evaluated. In the finite-dimensional optimum design formulation, geometry and cross-sectional shapes of classified group of piles are identified as design variables. The design objective is the total weight of piles, and the design constraints on stresses, penetration depth, and size limits are imposed. Several classes of practical design alternatives are sought through the linking and fixing of design variables. Among the available numerical optimization codes, both PLBA program and DNCONF subroutine in IMSL library are used. They are based on SQP algorithm and relatively easy to get. A dolphin of numerical example has 20 tubular steel piles, 4 vertical and 16 inclined. Optimum designs for different cases are successfully obtained for the practical purpose.

  • PDF

Algorithms for Ultrasound Elasticity Imaging (초음파 탄성 영상 알고리듬)

  • Kwon, Sung-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.484-493
    • /
    • 2012
  • Since the 1980s, there have been many research activities devoted to quantitatively characterizing and imaging human tissues based on sound speed, attenuation coefficient, density, nonlinear B/A parameter, etc., but those efforts have not yet reached the stage of commercialization. However, a new imaging technology termed elastography, which was proposed in the early 1980s, has recently been implemented in commercial clinical ultrasound scanners, and is now being used to diagnose prostates, breasts, thyroids, livers, blood vessels, etc., more quantitatively as a complementary adjunct modality to the conventional B-mode imaging. The purpose of this article is to introduce and review various elastographic algorithms for use in quasistatic or static compression type elasticity imaging modes. Most of the algorithms are based on the crosscorrelation or autocorrelation function methods, and the fundamental difference is that the time shift is estimated by changing the lag variable in the former, while it is directly obtained from the phase shift at a fixed lag in the latter.

A study on the Control Method of Single-Phase APF Using RRF Method (회전좌표계를 이용한 단상능동전력필터의 제어방법에 관한 연구)

  • 김영조;허진석;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.576-584
    • /
    • 2003
  • This paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. Constructing a imaginary second-phase giving time delay to load currents, making single-phase system into the system that has two phases, complex calculation is possible. In the previous method, it made a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle), but in proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used to the second phase. Instantaneous calculation of harmonic current is possible, because two phase have different phase. In this paper, it was done with instantaneous calculation using the rotating reference frames(RRF) that synchronizes with source-frequency, a reference of compensation currents, not applying to instantaneous reactive power theory which uses the existed fixed reference frames. The simulation and experiment about R-L loads using the current source were carried out, and the effect of the proposed method was preyed through the result of this experiment.

Nonlinear Analysis of a Forced Beam with Internal Resonances (내부공진을 가진 보의 비선형 강제진동해석)

  • 이원경;소강영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.147-152
    • /
    • 1991
  • 양단이 고정된 보가 변형할 때에는 중간 평면의 신장을 수반하게 된다. 운동 의 진폭이 증가함에 따라 이 신장이 보의 동적 응답에 미치는 영향은 심각 하게 된다. 이러한 현상은 응력과 변형도와의 관계가 선형적이라 하더라도 변형도와 변위와의 관계식은 비선형이 되며 결국은 보의 비선형 운동방정식 을 낳게된다. 보는 연속계이긴하지만 근사를 위하여 다자유도계로 간주할 수 있다. 비선형 다자유도계에 있어서는 선형화된 계의 고유진동수끼리 적절한 관계를 가질 때 내부공진이 발생할 수 있다. 양단이 고정된 곧은 보의 비선 형 동적응답이 그동안 많이 연구되어 오고 있으며, 집중질량을 가지고 직각 으로 굽은 보의 해석을 위하여 내부공진을 고려한 해석적 혹은 실험적 연구 가 이루어져 왔다. 그중에서도 Nayfeh등은 조화가진 하의 핀과 꺾쇠로 고정 된(hinged-clamped) 보의 정상상태응답을 해석하기 위해 두 모우드 사이의 내부공진을 고려하였다. 이 연구에서는 세 모우드 사이의 내부공진을 고려하 여 강제진행 중인 보의 비선형 해석을 다루고자 한다. 이 문제에 관심을 갖 게 된 동기는 "연속계의 비선형 해석에서 더 많은 모우드를 포함시키면 어 떤 결과를 낳게 될 것인가\ulcorner"라는 질문에서 생겨난 것이다. 갤러킨 법을 이용 하여 비선형 편미분 방정식과 경계 조건으로 표현되는 이 문제를 연립 비선 형 상미분 방정식으로 변환한다. 다중시간법(the method of multiple scales) 을 이용하여 이 상미분 방정식을 정상상태에서의 세 모우드의 진폭과 위상 에 대한 연립비선형 대수방정식으로 변환한다. 이 대수방정식을 수치적으로 풀어서 정상상태 응답을 구하고 Nayfeh등의 결과와 비교한다. 결과와 비교한다. studies, the origin of ${\alpha}$$_1$peak was attributed to the detrapping process form trap with 2.88[eV] deep of injected space charge from the chathode in the crystaline regions. The origin of ${\alpha}$$_2$ peak was regarded as the detrapping process of ions trapped with 0.9[eV] deep originated from impurity-ion remained in the specimen during production process of the material, in the crystalline regions. The origin of ${\beta}$ peak was concluded to be due to the depolarization process of "C=0"dipole with the activation energy of 0.75[eV] in the amorphous regions. The origin of ${\gamma}$ peak was responsible to the process combined with the depolarization of "CH$_3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorp

  • PDF

Radiation Pattern in Rectangular Microstrip Patch Antenna with Anisotropy Substrates and Superstrate (이방성 매질의 기판과 덮개층을 갖는 마이크로스트립 패치 안테나의 방사패턴)

  • Yoon, Joong-Han;Lee, Hwa-Choon;Kwak, Kyung-Sup
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.32-42
    • /
    • 2003
  • In this paper, radiation pattern of rectangular microstrip patch antenna with anisotropy substrates and superstrate is studied by using a rigorous full-wave approach and a moment method calculation. Dyadic Green's function is derived for selected anisotropy material by constitutive relation. From these results, integral equations of electric fields are formulated. The electric field integral equations are discretized into the matrix form by applying Galerkin's moment method and then the current coefficients are obtained.. After solving the current coefficients, the far-zone electric field in spherical coordinates can be obtained by using the stationary phase method. To verify the validity of numerical result, we compare our result with existing one and get a good agreement between them. From the numerical results, the radiation patterns for variation of uniaxial superstrate thickness, anisotropy ratio of substrate and superstrate layer are presented and analyzed.

  • PDF

Analysis and Comparison for a 4-Coil Magnetic Resonance Wireless Power Transfer System (4-코일 자기 공진 무선 전력 전송 시스템의 해석법 연구)

  • Lee, Gunbok;Park, Wee Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.168-179
    • /
    • 2013
  • The critical point analysis(CA) and impedance matching analysis(IA) are performed and compared for a 4-coil magnetic resonance wireless power transfer system. Because the operating frequency splits at short distance while the efficiency drops drastically at long distance in this system, the optimization technique is needed for either a specific distance or efficiency at the fixed frequency. CA uses the critical point where shows maximum efficiency in the entire range and IA uses the impedance matching technique to achieve maximum efficiency at the specific distance. Comparison result shows that IA is more efficient than CA. Also, it shows one side matching has a tradeoff relationship comparing to both side matching. By using four spiral resonant coils, the analysis was experimentally verified. The measured data agreed well with the calculated data.

The Reactive Power Compensation for a Feeder by Control of the Power Factor of PWM Converter Trains (PWM 컨버터 차량의 역률 제어를 통한 급전선로의 무효전력 보상)

  • Kim, Ronny Yongho;Kim, Baik
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • PWM converter trains exhibit excellent load characteristics in comparison with conventional phase-controlled trains with low power factors, as they can be operated at power factors which are close to unity by means of a voltage vector control method. However, in the case of a high track density or extended feeding, significant line losses and voltage drops can occur. Instead of operating these trains at a fixed unity power factor, this paper suggests a continuous optimal power factor control scheme for each train in an effort to minimize line losses and improve voltage drops according to varying load conditions. The proposed method utilizes the steepest descent algorithm targeting each car in the same feeding section to establish the optimized reactive power compensation levels that can minimize the reactive power loss of the feeder. The results from a simulation of a sample system show that voltage drops can be improved and line losses decreased.

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Additional Thermometer Code Locking Technique for Minimizing Quantization Error in Low Area Digital Controlled Oscillators (저면적 디지털 제어 발진기의 양자화 에러 최소화를 위한 추가 서모미터 코드 잠금 기법)

  • Byeongseok Kang;Young-Sik Kim;Shinwoong Kim
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.573-578
    • /
    • 2023
  • This paper introduces a new locking technique applicable to high-performance digital Phase-Locked Loops (DPLL). The study employs additional thermometer codes to reduce quantization errors in LC-based Digital Controlled Oscillators (DCO). Despite not implementing the entire DCO codes in thermometer mode, this method effectively reduces quantization errors through enhanced linearity. In the initial locking phase, binary codes are used, and upon completion of locking, the system transitions to thermometer codes, achieving high frequency linearity and reduced jitter characteristics. This approach significantly reduces the number of switches required and minimizes the oscillator's area, especially in applications requiring low DCO gain (Kdco), compared to the traditional method that uses only thermometer codes. Furthermore, the jitter performance is maintained at a level equivalent to that of the thermometer-only approach. The efficacy of this technique has been validated through modeling and design at the RTL level using SystemVerilog and Verilog HDL.

Effect of Imipramine on the Contractility of Single Cells Isolated from Canine Detrusor (Imipramine이 배뇨근 세포의 수축성에 미치는 직접작용)

  • Huh, Chan-Wook;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.293-302
    • /
    • 1994
  • The objective of this study was to establish a good methodology to isolate single smooth muscle cells that are alive and respond properly to pharmacological agents. Canine urinary bladders were employed as the source of single cells, and acetylcholine, atropine and imipramine were used as indicators of pharmacological responsiveness. Imipramine, an antidepressant drug exhibited the anticholinergic and calcium antagonizing properties on rat detrusor muscle. To establish a control value for a further experiment to elucidate the mechanism of action of imipramine on detrusor muscle, we measured the concentration-response of single cells to acetylcholine in the presesnce of imipramine by length of the cells and compared the result with the response in the presence of atropine. Tiny chops of smooth muscle taken from anesthetized canine urinary bladder were incubated in collagenase solution at $36^{\circ}C$ for 17-20 minutes. The collagenase solution included collagenase 1.2 mg/ml, soybean tryspin inhibitor 0.08 mg/ml, bovine serum albumin 2% in 10 ml Krebs-Henseleit buffer solution aerated with a consistent breeze of 95/5% $O_2/CO_2$, to maintain the pH at 7.4. After washing with plain K-H solution on 450 mesh, cells were dissociated from the digested tissue for 12-15 minutes. Cell suspension was transfered in 5 ml test tubes and acetylcholine was added for the final concentration to be $10^{-14}M{\sim}10^{-9}M$. To find the optimal time to fix the cells to determine the contractile responses, 1% acrolein was added 5, 10, 20, 30, 60 and 120 seconds after the administration of ACh. The length of cells fixed by acrolein were measured by microscaler via CCTV camera on phaes-contrast microscope. The average length of 50 cells from a slide glass was taken as the value of a sample at the very concentration point. Single cells were isolated from canine detrusor. The length of untreated cells varied from 82 ${\mu}m$ to 94 ${\mu}m$. The maximal response to actylcholine $10^{-9}M$ was accomplished within 5 seconds of exposure, and the shortening was $19{\pm}3$%. Atropine reduced the contraction of the cells concentration-dependently. Imipramine which exerts a cholinergic blocking action on some smooth muscles also reduced the contraction concentration-dependently and by a similar pattern as atropine. These findings document that imipramine may exerts a cholinergic blocking activity in the single smooth muscle cells isolated from canine urinary bladder.

  • PDF