• Title/Summary/Keyword: 고전압 기기

Search Result 87, Processing Time 0.175 seconds

High Voltage Transformer Design using Self-Resonant Characteristics of Transformer (트랜스포머의 자가공진 특성을 이용한 고전압 트랜스포머 설계)

  • Lee, Sueng-Hwan;Cho, Dae-Kweon
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, self-resonant characteristics of transformers were analyzed in accordance with changes of characteristics regarding to the stray capacitance, the volume of winding and the winding ratio were organized by formulas. Generally, the stray capacitance is considered as an unnecessary factor in processing transformers design as well as one of the inherent characteristics. In particular, these characteristics can be appeared clearly in the high frequency driving and Electrical resonance occurs in transformer, according to coupling with a magnetic factor at a particular frequency. In the case of high-voltage output applications, such as medical equipments, It is required to output high-voltage gain. Therefor, If Self-Resonant Characteristic is applied to High-Voltage transformer design, Not only the transformer and circuit but also related the system size can be reduced. So we propose it as one of additional high voltage transformer design methods.

Design of a Voltage Protection Circuit for DC-DC Converter of the Potable Device Application (소형 휴대기기용 DC-DC 변환기를 위한 전압 보호회로 설계)

  • Park, Ho-Jong;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • 전자공학회논문지 IE
    • /
    • v.49 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • In this paper, a potable device application for DC-DC converter was designed for voltage protection circuit. Voltage protection circuit to offer the under voltage lock out and over voltage protection consists of a comparator and bais circuits were implemented using. XFAB 1um CMOS process, SPICE simulations was confirmed through the characteristics. Simulation results, under voltage lock out input voltage is 4.8 V higher when the turn-on and, 4.2 V less when turn-off. When the input voltage is low voltage is applied can be used to prevent malfunction of the circuit. Over voltage protection is 3.8 V reference voltage when the output voltage caused by blocking circuit prevents device destruction can be used to improve the stability and reliability. The virtual control circuits of the DC-DC converter connected. According to the results of the abnormal voltage, voltage protection circuit behavior was confirmed. The proposed voltage protection circuit of the DC-DC converter cell is useful are considered.

Optimization and Application Research on Triboelectric Nanogenerator for Wind Energy Based High Voltage Generation (정전발전 기반 바람에너지 수확장치의 최적화 및 고전압 생성을 위한 활용 방안)

  • Jang, Sunmin;Ra, Yoonsang;Cho, Sumin;Kam, Dongik;Shin, Dongjin;Lee, Heegyu;Choi, Buhee;Lee, Sae Hyuk;Cha, Kyoung Je;Seo, Kyoung Duck;Kim, Hyung Woo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.243-248
    • /
    • 2022
  • As the scope of use of portable and wearable electronic devices is expanding, the limitations of heavy and bulky solid-state batteries are being revealed. Given that, it is urgent to develop a small energy harvesting device that can partially share the role of a battery and the utilization of energy sources that are thrown away in daily life is becoming more important. Contact electrification, which generates electricity based on the coupling of the triboelectric effect and electrical induction when the two material surfaces are in contact and separated, can effectively harvest the physical and mechanical energy sources existing in the surrounding environment without going through a complicated intermediate process. Recently, the interest in the harvest and utilization of wind energy is growing since the wind is an infinitely ecofriendly energy source among the various environmental energy sources that exist in human surroundings. In this study, the optimization of the energy harvesting device for the effective harvest of wind energy based on the contact electrification was analyzed and then, the utilization strategy to maximize the utilization of the generated electricity was investigated. Natural wind based Fluttering TENG (NF-TENG) using fluttering film was developed, and design optimization was conducted. Moreover, the safe high voltage generation system was developed and a plan for application in the field requiring high voltage was proposed by highlighting the unique characteristics of TENG that generates low current and high voltage. In this respect, the result of this study demonstrates that a portable energy harvesting device based on the contact electrification shows great potential as a strategy to harvest wind energy thrown away in daily life and use it widely in fields requiring high voltage.

Noise Evaluation Algorithm for Applying Complex Denoising Technique in On-line Partial Discharge Diagnosis System for Power Apparatus (전력기기의 운전중 부분방전 진단장치에서 복합잡음제거 적용을 위한 잡음평가 알고리즘)

  • Yi, Sang-Hwa;Youn, Young-Woo;Choo, Young-Bae;Kang, Dong-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.70-76
    • /
    • 2009
  • This paper introduces an evaluation code, which can numerically express the noise possessing degree of signals. By using this code, the best kind and setting of noise suppressing techniques can be chosen automatically. This code is applied to three kinds of specific denoising techniques; those are simple noise removing method in the count versus phase distribution, fuzzy logic method based on noise type in magnitude versus phase plot, and lastly, the technique using grouping characteristics of PD pulses in 3D plot of magnitude versus phase versus cycle. The algorithm shows good performance in the various real PD signals measured from various high voltage apparatuses in Korea.

The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques (신호처리 기술에 의한 부분방전 방사전자파의 특징 추출)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2002
  • In recent years, diagnostic techniques have been investigated to detect a partial discharge(PD) in a high voltage electrical equipment. Because PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise, the accuracy and credibility of PD measurement might be influenced by surrounding interference. Using the technique of PD detection by electromagnetic wave, we have studied the characteristics of both PD and substation-in interference signal. Also, we propose a wavelet packet transform based technique to perform a feature extraction from the interference and PD signal and a classification of the extracted features. The results show that time-frequency characteristics between PD and interference can be obviously distinguished. It is helpful for the development of the insulation diagnosis technique.

A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus (고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구)

  • Lee, Chang-Hoon;Kim, Hyo-Chul;Cho, Young-Haw;Kim, Hyun;Jo, Sung-Choe;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

A Study on the Application of Convergence Measurement System to Inverse Calculation of Tunnel Lining Sectional Forces (터널 라이닝 단면력 역산을 위한 유지관리 내공변위계측시스템 적용 연구)

  • 이대혁;김기선;한일영;박연준;유광호
    • Tunnel and Underground Space
    • /
    • v.11 no.2
    • /
    • pp.146-155
    • /
    • 2001
  • An inverse calculation method to obtain sectional forces, axial force and flexural moment of a tunnel concrete lining was developed by utilizing convergence measurements acquired at the maintenance stage. To monitor the behavior of the lining, DOCS system was applied to a subway tunnel section. The method was proved to be effective, yielding the same results as measured forces of buried instruments. Many effects such as vibration of sensors, vibration due to test train operation, the variation of temperature and high voltage were checked and a new management scheme for tunnel maintenance was proposed.

  • PDF

A study of sensitive reduction from cable when off-line partial discharge measuring (OFF-LINE 부분방전 측정 시 CV케이블에 의한 방전량 감도저하 현상 고찰)

  • Yi, Jong-Seuk;Lee, Eun-Chun;Chae, Ji-seog;Ham, Dong-Younf;Ok, Yeon-Ho;Byun, Du-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1177-1178
    • /
    • 2015
  • 국내 전력설비는 70년대 이후 제3차 경제개발 5개년 계획에 따라 중화학공업의 발전과 함께 급속히 성장해왔다. 과거 개발 위주의 산업구조에서 급속히 팽창한 전력설비는 21세기에 들어서면서 30~40년 장기 사용에 따른 노후화가 진행되었고, 증가하는 전력수요에 대응하기 위한 발전 및 송전 용지 확보의 어려움으로 인하여 전력설비의 신규 증설에 많은 어려움을 격고 있는 실정이다. 따라서 전력설비의 안전성과 신뢰성을 확보하기 위해 적절한 교체시기 선정 및 최적의 자산관리 필요성에 대해서 최근 관심을 가지기 시작하였고, 이러한 전력설비의 최적 자산관리에 핵심적인 전력설비의 상태평가 기술의 발달로 과거 시간기준의 유지보수(Time Based Maintenance)에서 최근 노후설비의 증가와 진단기술의 발달에 따른 예방보전(Preventive Maintenance)에 의한 상태기준 유지보수(Condition Based Maintenance)개념으로 전환되고 있다. 고전압 회전기기(발전기, 전동기)의 상태평가를 위한 핵심기술인 Off-line 부분방전시험이 널리 적용되고 있으며, 본 논문에서는 부분방전 측정 시험 시 대상설비 단자부의 인출케이블에 의한 감도저하 현상에 대해 고찰 하였다.

  • PDF

Effects of Process Parameters on Corrosion Properties of PEO Coatings Formed on Al Alloy (공정변수에 따라 Al 합금 상에 형성된 PEO 코팅층의 내식성 평가)

  • Lee, Jeong-Hyeong;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.139-139
    • /
    • 2018
  • 최근 자동차 산업을 중심으로 한 수송용 기기의 경량화 추세에 따라 대표적인 경량금속 소재인 알루미늄 합금에 대한 수요가 증가하고 있으며 이에 따라 알루미늄 합금 표면에 다양한 특성을 부여할 수 있는 표면개질 기술에 대한 필요성이 부각되고 있다. 알루미늄 합금의 대표적인 표면처리기술인 아노다이징과 유사한 원리로 표면에 세라믹 코팅층을 형성할 수 있는 기술인 플라즈마 전해 산화(Plasma electrolytic oxidation, PEO)가 주목을 받고 있다. PEO 코팅법은 전해액 내에 소재를 침지시키고 400 ~ 600V에 이르는 고전압을 인가시켜 마이크로 방전을 유도하여 표면에 치밀한 세라믹 층을 형성시키는 기술이다. 본 연구에서는 PEO법으로 표면 개질된 Al 합금 표면의 표면 조직 특성과 전기화학 특성을 평가하고, 코팅층 특성에 미치는 공정 변수의 영향을 분석하고자 하였다. PEO 처리를 위해 사용된 소재는 상용 Al 합금 판재(Al 5083-O)로서 $2cm{\times}2cm$로 절단하여, 에머리페이퍼로 1000번까지 연마하여 사용하였다. 시험을 위한 PEO 처리 시스템은 전해액 수조, 일정 온도 유지를 위한 열교환기와 칠러, 전원 발생을 위한 전원공급기(power supply)로 구성되었다. 전해액은 약 알칼리 수용액을 이용하였으며, 전원 공급기를 통해 시험편에 펄스 전류를 인가하였다. PEO 처리 후 시편에 대하여 SEM, EDS, XRD 등을 이용한 표면 특성 평가를 실시하였다. 또한 코팅층의 전기화학적 부식 특성 평가를 위해 해수용액에서 동전위분극실험을 실시하였다. 시험 결과, Al 합금의 PEO 처리 시 내식성은 개선되는 것으로 확인되었으며, 공정변수는 표면의 미세조직 및 전기화학적 특성에 큰 영향을 미치는 것으로 나타났다.

  • PDF