• Title/Summary/Keyword: 고전압 기기

Search Result 87, Processing Time 0.032 seconds

Filed Programmable Logic Control and Test Pattern Generation for IoT Multiple Object switch Control (사물인터넷 환경에서 다중 객체 스위치 제어를 위한 프로그래밍 가능한 로직제어 및 테스트 패턴 형성)

  • Kim, Eung-Ju;Jung, Ji-Hak
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 2020
  • Multi-Channel Switch ICs for IoT have integrated several solid state structure low ON-resistance bi-directional relay MOS switches with level shifter to drive high voltage and they should be independently controlled by external serialized logic control. These devices are designed for using in applications requiring high-voltage switching control by low-voltage control signals, such as medical ultra-sound imaging, ink-jet printer control, bare board open/short and leakage test system using Kelvin 4-terminal measurement method. This paper describes implementation of analog switch control block and its verification using Field programmable Gate Array (FPGA) test pattern generation. Each block has been implemented using Verilog hardware description language then simulated by Modelsim and prototyped in a FPGA board. Compare to conventional IC, The proposed architecture can be applied to fields where multiple entities need to be controlled simultaneously in the IoT environment and the proposed pattern generation method can be applied to test similar types of ICs.

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Pin-Type Vibrotactile Display (핀형 진동촉각 출력장치)

  • Back, Jong-Won;Choi, Dai-Sung;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.463-466
    • /
    • 2006
  • 최근 전자기기에서 시각 및 청각과 함께 촉각 디스플레이가 정보를 출력하는 중요한 수단으로 부각되고 있다. 본 논문에서는 촉각 정보 출력을 위한 소형진동촉각(vibrotactile) 디스플레이 모듈을 개발하였다. 개발한 모듈은 주파수와 진폭을 독립적으로 조절할 수 있으며 핀이 직접 피부에 자극을 주기 때문에 몸체 전체가 떨리는 기존의 진동모터보다 정밀하고 다양한 촉각 표현을 할 수 있다. 또한 고전압을 이용하는 Piezo 방식과 달리 낮은 전력으로 동작이 가능하여 휴대장치에 직접 장착할 수 있는 장점을 가지고 있다.

  • PDF

Development of High Voltage and High Energy Density Capacitor for Pulsed Power Application (펄스파워용 고전압 고에너지밀도 커패시터 개발)

  • 이병윤;정진교;이우영;박경엽;이수휘;김영광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.203-210
    • /
    • 2003
  • This paper describes high voltage and high energy density capacitor developed for pulsed power applications. The rated voltage of the developed capacitor is DC 22 [kV], the capacitance is 206 [$\mu$F] and the energy density is about 0.7 [kJ/kg]. Polypropylene film and kraft paper were used as the dielectrics. The ratio of the thickness of each dielectric material which consists of the composite dielectric structure, stacking factor and the termination method were determined by the charging and discharging tests on model capacitors. In terms of energy density, the developed capacitor has higher energy density compared with the products of foreign leading companies. In addition, it has been proved that the life expectancy can be more over 2000 shots through the charging and discharging test. The voltage reversal factor was 20%. This capacitor can be used as numerous discharge applications such as military, medical, industrial fields.

A high voltage resonant genrator for X-ray apparatus (X-선 발생기기용 공진형 고전압 발생기)

  • 김학성;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.217-225
    • /
    • 1996
  • This paper describes a high power resonant inverter for diagnostic X-ray generators using zero-voltage soft-switching technology. The system consists of a step-down chopper, a resonant phase-shift PWM inverter, a hihg-voltage diode, and high voltage cables a smoothing DC capacitor. The inverter makes use the leakage inductance of the hihg-voltage transformer and external capacitor as resonant components. The rectified input voltage is controlled by a step-down chopper with input voltage compensator. The output regualtion is obtained by a resonant phase-shift PWM inverter with the digital feedback controller using DSP (digital signal processor), resulting in fast rising time and wide output voltage variation. The theoretical results are correlated with results from an experimental prototype of a 7-kVp, 300mA (21kW).

  • PDF

Study on the comparison of breakdown voltage characteristics between dry air and air (Dry air와 공기의 절연파괴전압 특성 비교에 관한 연구)

  • Kang, Hyoung-Ku;Nam, Seok-Ho;Kim, Hong-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1532-1533
    • /
    • 2011
  • 고압배전반과 같은 고전압 전력기기의 절연매질로는 고체 절연매질이 사용되기도 하지만 주로 공기나 $SF_6$와 같은 기체가 사용된다. 공기를 절연매질로 사용하고 있는 고압배전반과 같은 경우에는 장시간 운전 시 먼지나 수분 등과 같은 이물질에 의한 열화현상이 보고되고 있으며, $SF_6$를 사용하는 고압배전반의 경우에는 최근 온실효과와 같은 환경오염의 원인으로 지목되고 있는 등의 문제점을 가지고 있다. 따라서 이와 같은 열화현상이나 환경오염 유발과 같은 문제점을 해결하기 위한 방안 중의 하나로서 공기 중의 수분을 제거한 dry air를 이용한 친환경 고압배전반의 개발에 관한 연구가 활발히 이루어지고 있다. 본 연구에서는 dry air의 절연내력특성에 관한 실험을 수행하여 일반 공기의 절연내력특성과 비교하였다.

  • PDF

Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen (액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구)

  • Na, J.B.;Ko, T.K.;Kang, H.;Seok, B.Y.;Kim, T.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

Characteristics of AC Treeing for Three Epoxy Resins for High Voltage Heavy Electric Machine Appliances (고전압 중전기기용 에폭시 수지 3종에 대한 교류트리잉 파괴특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1322-1329
    • /
    • 2018
  • In this paper, the reliability test of three kinds of epoxy resin for GIS Spacer, which is a high voltage based heavy electric machine, AC electrical treeing experiments were performed. Three types of epoxy resins, Araldite B41, CT 5531 CI and B46, have slight viscosity differences. An non-uniform electric field, E = 1149.4 kV/mm, as the needle to plate electrode, a power source with a frequency of 1 kHz was applied to the tree electrode for accelerated deterioration. The treeing phenomena of the three kinds of epoxy resin all initiated, propagated, and destroyed by the branch tree. Epoxy Resin B46 was 145 times longer than B41 and 53 times longer than CT 5531CI. I think that the choice of epoxy resin is very important in choosing high voltage heavy electric machine insulation materials.

Design of High Voltage Conversion Ratio Power Conversion Circuit for Ionizer (이오나이저를 위한 높은 전압 변환비를 가지는 전력변환회로 설계)

  • So, Pyung-Ho;Choi, Yeon-Woo;Lee, Byoung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.187-188
    • /
    • 2017
  • 이오나이저는 에어컨이나 공기청정기와 같은 전자기기에서의 공기 정화기능이나 반도체 장비에서 웨이퍼에 먼지가 부착 되는 문제를 해결하기 위한 정전기 제거 기능 등의 용도로 활용되고 있다. 이오나이저의 동작을 위해서는 교류나 직류 형태를 가지는 수 kV의 고전압을 발생시킬 수 있는 높은 전압 변환비를 가지는 전원장치가 필요하다. 본 논문에서는 5 V 전원을 입력으로 하고, 5 kV 전원을 출력으로 하는 직류 형태의 이오나이저용 전력변환회로의 소형화 및 저가격화를 목표로 설계하고 검증한 내용에 대하여 논의하고자 한다.

  • PDF