Park, Hee Ran;Yoon, So Jung;Park, Han-Sul;Shin, Jung-Kue
Korean Journal of Food Science and Technology
/
v.45
no.5
/
pp.590-597
/
2013
High voltage pulsed electric fields (PEF) treatment is a promising non-thermal processing technology that can replace or partially substitute for thermal processes. The aim of this research was to investigate the microbial inactivation mechanisms by PEF treatment in terms of physiological changes to Saccharomyces cerevisiae. PEF was applied at the electric field strength of 50 kV/cm, treatment time of 56 ${\mu}s$ and temperature of $40^{\circ}C$. The microbial cells treated with PEF showed loss of salt tolerance on the cell membrane and collapse of the relative pH gradient on in-out of cells. Cell death or injury resulted from the breakdown of homeostasis, decreased $H^+$-ATPase activity, and loss of glycolysis activity.
High voltage pulsed electric fields (PEF) treatment is one of the more promising nonthermal technologies to fully or partially replace thermal processing. The objective of this research was to investigate the microbial inactivation mechanisms of PEF treatment in terms of intra- and extracellular changes in the cells. Saccharomyces cerevisae cells treated with PEF showed cellular membrane damage. This resulted in the leakage of UV-absorbing materials and intracelluar ions, which increased with increasing treatment time and electric fields strength. This indicates that PEF treatment causes cell death via membrane damage and physical rupture of cell walls. We further confirmed this by Phloxine B staining, a dye that accumulates in dead cells. Using scanning and transmission electron microscopy, we observed morphological changes as well as disrupted cytoplasmic membranes in PEF treated S. cerevisae cells. In addition, PEF treatment led to damaged chromosomal DNA in S. cerevisiae.
Park, Seong Hwan;Ham, Young Jae;Kim, Jeong Seok;Kim, Kyoung Hun;So, Seong Min;Jeon, Min Seok
Journal of the Korean Crystal Growth and Crystal Technology
/
v.29
no.6
/
pp.270-275
/
2019
Mica capacitor is being adopted for high voltage firing unit of guided weapon system because of its superior impact enduring property relative to ceramic capacitor. Reliability of localized mica high voltage capacitors was verified through environmental test like terminal strength test, humidity test, thermal shock test and accelerated life test for application to high voltage firing unit. Failure mode of mica capacitor is a decrease of insulation resistance and its final dielectric breakdown. Main constants of accelerated life model were derived experimentally and voltage constant and activation energy were 5.28 and 0.805 eV respectively. Lifetime of mica capacitor at normal use condition was calculated to be 38.5 years by acceleration factor, 496, and lifetime at accelerated condition and this long lifetime confirmed that mica high voltage capacitor could be applied for firing unit.
고전압 전력설비 진단은 기기의 열화 상태를 측정하여 이상 사고를 미리 예측하여 방지하는 것을 목적으로 실시한다. 고전압 전력설비의 유지관리 방안은 일정 시간 경과후 보수하는 개념(TBM: Time Based Maintenance) 이후 설비의 상태를 진단하여 유지보수 방안을 결정하는 개념(CBM: Condition Based Maintenance)으로 진보해 감에 따라 전력설비의 상태진단 기술의 중요성은 증대될 전망이다. 고전압 전력설비의 절연진단은 직류시험(절연저항, PI)과 교류시험($tan{\delta}$, PD)이 실시되며 과거 진단 데이터의 추세분석을 통한 정확한 상태진단이 요구되고 있다. 고압 유도 전동기 절연진단 데이터 관리 전산화 모델은 고전압 전력기기(발전기, 변압기, 전동기, 케이블 등)의 절연진단 및 유지보수 이력에 관한 자료들을 저장, 조회 및 검색을 하기 위한 데이터베이스를 구축하고 구축된 데이터를 활용하여 과거 이력조회, 추이분석, 진단 데이터의 분석기법을 통한 전력기기의 상태평가로 합리적인 개 대체 의사결정을 지원한다. 또한, 유입식 변압기의 절연유 가스분석 알고리즘을 전산화 하여 10종 가연성 가스에 따른 Gas Pattern 평가로 고장 원인, 현상 및 조치 등에 대한 출력이 가능한 프로그램의 개발로 고전압 전력설비 진단기술과 IT기술의 융 복합 기술로서 고전압 전력설비의 유지관리 기술을 한 차원 더 진보시킬 것으로 판단된다.
Proceedings of the Korean Vacuum Society Conference
/
2011.02a
/
pp.221-221
/
2011
수 Tera Watt급의 가속기 및 펄스파워 시스템은 다수의 스위치를 사용하고 있으며, 이와 같은 가속기 및 시스템의 성능은 기체방전 스위치의 성능에 직접적으로 관련되어 있다. 일반적으로 이와 같은 기체방전, 액체방전 고출력 스위치는 다목적으로 많은 연구와 개발에 응용되고 있다. 예를 들어 천둥 펄스전자빔 발생장치는 12개의 Marx gap 및 3개의 100 kV 펄스충전 전기트리거 gap을 가지고 있다. 기체 방전 또는 액체 방전 펄스 충전 갭 스위치의 음극에 펄스 고전압이 인가되면 이로 인하여 음극에서 전자빔이 발생한다. 내부에는 전자빔이 양극과 충돌하는 순간 양극표면에 플라스마가 형성된다. 이와 같은 플라스마 sheath는 축 방향 이극관 안에서 양극 충전 에서 음극으로 팽창하면서 전파하며, 또한 거의 동시에 음극표면에도 플라스마가 형성되어 음극에서 양극으로도 팽창하여 전파하게 된다. 이와 같은 펄스충전 고출력 갭 스위치 안에서 발생되는 방전 플라스마의 특성에 관한 갭 breakdown 과정에 대한 특성연구를 한다. 고출력 스위치의 특성 조건으로는 방전전압, 방전시간, jitter 등이 있다. 본 연구에서는 최대전압 600 KV, 최대전류 88 KA, 펄스 폭 60 ns의 특성을 가지는 고전압 펄스 시스템 '천둥'을 이용하여 방전 챔버에 고전압 펄스를 인가하고 N2와 SF6 혼합기체 종류와 압력에 따른 현상을 전기, 광학적으로 연구하였다. 전극은 구리텅스텐 합금재질의 표준전극을 사용하였고, 전극 간격은 20 mm로 고정하였다. 방전 챔버 압력을 100 torr에서 4 기압까지 변화시켜가며 실험을 진행하였고, N2에 대한 SF6의 혼합비율을 0%~100%까지 변화시키며 실험을 진행하였다. 실험결과 방전전압은 압력이 증가함에 따라 증가하다가 2 기압 이상에서는 완만히 증가하는 경향을 보였고, SF6 혼합비율은 0~10%까지 급격히 증가하고, 그 이상의 혼합비율에서는 완만히 증가하였다. 전자온도는 SF6 혼합비율이 0~10%일 때 급격히 증가하여 이후에는 포화되는 경향을 보였고, 압력에 따라서는 큰 경향성을 보이지 않았다.
지금까지 통상적으로 사용하고 있는 Plasma Lighting System(이하 PLS)의 마그네트론 구동용 고전압, 고전류 전원장치는 성층 철심 HVT를 이용한 방식을 적용하고 있다. 이 방식은 상용 주파수를 사용하므로, 승압트랜스포머나 배 전압용의 커패시터를 대형으로 하기 때문에 고중량, 저효율 및 출력의 한계성과 광출력에서 플리커현상 둥의 단점을 지닌다. 이의 해결책으로 최근 인버터 방식의 전원장치를 PLS에 적용 하고자 하는 연구가 활발하게 진행되고 있다. 설계한 PLS 마그네트론 구동을 위한 고전압, 고전류 전원장치는 기존의 스위칭 기술을 이용 낮은 스위칭 손실의 고속 스위칭을 통한 시스템의 소형, 경량화 및 고전력밀도를 가지도록 하였고 $\mu$-com을 이용하여 Micro-wave의 누설에 따른 사고를 방지하기 위하여 광 검출과 마그네트론 온도 검출 등의 시스템 보호 기능을 가지고 있으며, 고전압 출력을 고저 항으로 분압하고 PWM 제어기에 피드백하여 매우 안정된 출력 전압이 얻어지도록 하였다. 또한 출력 전류를 제한 할 수 있게 하여 광량 조절이 가능하도록 하였다.
Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
/
2005.11a
/
pp.395-398
/
2005
본 논문에서는 인체모형을 이용하여 고압감전실험을 하였다. 케이블을 인체모형이 감싸쥐고 있는 경우와 절연체를 통한 접촉을 임펄스와 변압기를 이용하였다. 이때 인가전압은 22,900[V]이다. 고전압에 의해 절연체가 파괴되어 감전의 위험이 있는 것을 알 수 있었으며, 실험을 통해 분석하고자 하였다. 고전압에서의 직 간접적인 감전형태를 알 수 있었으며 고전압 감전사고를 예방하는 중요한 자료로 사용될 것이다.
고전압 전력기기분야에 광섬유 전압센서를 적용해보고자하는 연구는 20여년 전부터 꾸준히 진행되어 왔었다. 본 연구에서는 구조가 간편한 광섬유 패브리페로 간섭계를 이용한 고전압기기 적용형 전압센서가 시도되었다. 신호변환은 정전력을 이용하여 전압의 변화를 광섬유스트레인센서로 검출하며, 해상도를 확보하기 위하여 공진기의 길이를 1cm, 위상을 스캐닝하는 변조방법을 적용하였고, 교류전압 1000V까지 적용 타당성을 시험하였다.
Unlike an international combustion engine car, a battery-powered electric vehicle requires an additional heat source for its heating system. A high-voltage coolant heater has the advantages of high efficiency and a wide operating temperature range. In its development, the geometry design of the coolant flow path is essential. This paper presents the thermal flow simulations of a 7kW high-voltage heater with symmetric serpentine flow channels arranged parallelly. The heater performance was evaluated from the simulation results in terms of the pressure and temperature differences and the flow uniformity. The proposed design showed a greater flow resistance and similar heat exchanging capability than the existing parallel serpentine design. It has the advantage of a relatively wide low-temperature surface area, where the control circuit board susceptible to high temperatures can be located.
Journal of the Korea Institute of Information and Communication Engineering
/
v.16
no.8
/
pp.1741-1746
/
2012
This paper introduces a new DC-DC voltage multiplier using a Dickson's charge pump and a modified voltage doubler. The voltage obtained from a conventional Dickson's chrage pump was reused for accelerating the voltage multiplication and the architecture of the proposed voltage multiplier would not decrease the device reliability of DMOS. The proposed 6-stage voltage multiplier generates about 33V with 3V voltage source. To evaluate the proposed voltage multiplier, simulations were performed with Magna DMOS technology. The simulated voltage multiplication agrees well with a theoretical value, therefore, this paper introduces a new fast voltage multiplier with minimum devices.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.