• Title/Summary/Keyword: 고압축비

Search Result 505, Processing Time 0.034 seconds

A Study on the Split Strength Characteristics of High Strength Concrete Sphere for Seismic Isolation (면진용 고강도 콘크리트 구의 할열강도 특성에 관한 연구)

  • Kim, Dong-Baek;Kim, In-Bae;Kim, Myung Gon;Park, Bong-Gwan
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.466-473
    • /
    • 2018
  • Purpose: Nowadays, it is the trend that seismic isolation method and combined method are used for seismic retrofitting, if concrete sphere foundation(CSF) system is applied to mid and low rise RC structure for the seismic isolation, the characteristics of concrete sphere, etc split tensile strength will be need. Method: The various experiments are carried out to know the split strength of high strength concrete sphere(60Mpa) and the ratio of split strength of concrete sphere to standard cylinder specimen, the size effect of concrete sphere with diameter. Results: It was purposed that the split strength of concrete sphere with diameter 150mm will be lower than that of cylinder specimen but, the average value is 4.39 Mpa and the ratio is higher than that of cylinder specimens, each 3.8% and 13.7%, the reason of this result is thought that the internal stress action of spot load and line load are different. Conclusion: There is a standard method for split tensile strength of cylinder type specimen, but there are few studies for the tensile split of concrete sphere. And therefore, in this study, theoretical and experimental details of concrete sphere will be served for the concrete sphere foundation or other sequent studies.

Performance of Uncompressed Audio Distribution System over Ethernet with a L1/L2 Hybrid Switching Scheme (L1/L2 혼합형 중계 방법을 적용한 이더넷 기반 비압축 오디오 분배 시스템의 성능 분석)

  • Nam, Wie-Jung;Yoon, Chong-Ho;Park, Pu-Sik;Jo, Nam-Hong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.108-116
    • /
    • 2009
  • In this paper, we propose a Ethernet based audio distribution system with a new L1/L2 hybrid switching scheme, and evaluate its performance. The proposed scheme not only offers guaranteed low latency and jitter characteristics that are essentially required for the distribution of high-quality uncompressed audio traffic, and but also provide an efficient transmission of data traffic on the Ethernet environment. The audio distribution system with a proposed scheme consists of a master node and a number of relay nodes, and all nodes are mutually connected as a daisy-chain topology through up and downlinks. The master node generates an audio frame for each cycle of 125us, and the audio frame has 24 time slotted audio channels for carrying stereo 24 channels of 16-bit PCM sampled audio. On receiving the audio frame from its upstream node via the downlink, each intermediate node inserts its audio traffic to the reserved time slot for itself, then relays again to next node through its physical layer(L1) transmission - repeating. After reaching the end node, the audio frame is loopbacked through the uplink. On repeating through the uplink, each node makes a copy of audio slot that node has to receive, then play the audio. When the audio transmission is completed, each node works as a normal L2 switch, thus data frames are switched during the remaining period. For supporting this L1/L2 hybrid switching capability, we insert a glue logic for parsing and multiplexing audio and data frames at MII(Media Independent Interlace) between the physical and data link layers. The proposed scheme can provide a good delay performance and transmission efficiency than legacy Ethernet based audio distribution systems. For verifying the feasibility of the proposed L1/L2 hybrid switching scheme, we use OMNeT++ as a simulation tool with various parameters. From the simulation results, one can find that the proposed scheme can provides outstanding characteristics in terms of both jitter characteristic for audio traffic and transmission efficiency of data traffics.

A Study on the Characteristics of Mortar Using Foaming Agents (기포제(起泡劑)를 사용(使用)한 모르터의 제특성(諸特性)에 관(關)한 연구(硏究))

  • Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.15 no.1
    • /
    • pp.82-94
    • /
    • 1988
  • This study was performed to obtain the basic data which can be applied to use of foaming mortars. The results obtained were summarized as follows ; 1. The lowest water-cement ratios were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1.6-53.1% by mix-foaming type and 4.4-24.1% by pre-foamed type than cement mortar. 2. The highest bulk densities were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of bulk densities were increased in richer mixing ratio and more addition of foaming agent. 3. The bulk densities were decreased up to 38.8-55.9% by mix-foaming type and 9.7-23.6% by pre-foamed type than cement mortar. 4. The lowest absorption rates were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of absorption rates were increased in richer mixing ratio and more addition of foaming agent. 5. Absorption rates when immersed in 72hours were shown up to 3.41-5.85 times greater by mix-foaming type and 1.05-1.55 times greater by pre-foamed type than those of cement mortar. it was significantly higher at the early stage of immersed time than cement mortar. 6. The highest strengths were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of strengths were increased in poorer mixing ratio and more addition of foaming agent. 7. The strengths were decreased up to 77.0-92.8% by mix-foaming type and 36.7-74.4% by pre-foamed type than cement mortar. 8. The lowest air contents were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of air contents were increased in richer mixing ratio and more addition of foaming agent. 9. Air contents were shown up to 26.0-63.8 times greater by mix-foaming type and 5.8-17.7 times greater by pre-foamed type than those of cement mortar. 10. The correlations between bulk density, absorption rate, compressive strength and air content were highly significant. The multiple regression equations of bulk density, absorption rate, compressive strength, tensile strength, bending strength and air content were computed depending on a function of mixing ratio and addition of foaming agent. They were generally highly significant.

  • PDF

Effect of Maximum Size and Contents Method of Recycled Aggregate Powder on Engineering Properties of the Cement Mortar (순환골재 미분말의 최대입경 및 치환방법이 시멘트 모르터의 공학적 특성에 미치는 영향)

  • Han, Min-Cheol;Jeon, Kyu-Nam
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.129-136
    • /
    • 2010
  • This study is to investigate experimentally the engineering characteristics of cement mortar according to the replacement method and contents of recycled aggregate powder (RP) by collecting the recycled aggregate powder with the maximum size of below 0.08 mm and 0.15 mm. then, the results of the study can be summarized as follows. The flow of flesh mortar represented a trend in decreasing while the recycled aggregate powder was substituted as it is compared with that of plain. In addition, in case of correlation between tests, it appeared that the correlation between flow and ring flow is big. In the case of the characteristics of hardened mortar, the strength showed more improvements as the RP was substituted to aggregate than the case, which is substituted to aggregate. In addition, it was verified that the results in which the RP was substituted to aggregate by 5% represented similar values to that of the plain according to the passage of age.

  • PDF

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

A Study on the Development of Sound Absorption Material Using Perlite for Noise Barrier Wall (펄라이트를 이용한 방음벽의 흡음소재 개발에 관한 기초적 연구)

  • Jo, Young-Kug;Yang, Ju-Kyung
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.653-660
    • /
    • 2008
  • The purpose of this study is to analyze the optimal mix design of the sound absorption material that is made from perlite and various binder systems for noise barrier wall. The polymer cement slurry which is made from two types of polymer dispersions, and silicone type inorganic material are used as binder. The test specimens are prepared with various polymer cement ratios, binder ratios, and tested for strengths, freezing and thawing and sound absorption performance by the tube and the reverberation room methods. From the test results, the difference of sound absorption coefficient by the tube method is a little recognized, however, noise reduction coefficient (NRC) of test specimens bound by the polymer cement slurry is in the ranges of 0.48 to 0.51. They are a little higher than those bound by cement only, and are lower values than recommended value of 0.7 by the Ministry of Environment. However, the sound absorption coefficient of test specimens at low frequency range of 250 to 500 Hz by reverberation room method shows very high values as 0.84 to 1.00, and 0.57 to 0.77 at the high frequency. The test specimens with polymer cement slurry binder have a good balance between performance and cost, and have proper properties in strengths, freezing and thawing resistance as sound absorption material for noise barrier wall. It is apparent that the good sound absorption material can be produced according to the optimum mix design that is recommended from this study.

Flexural Behavior of Segmental U-Girder and Composite U-Girder Using Ultra High Performance Concrete (초고강도 섬유보강 콘크리트를 사용한 분절형 U거더 및 합성 U거더의 휨거동)

  • Lee, Seung-Jae;Makhbal, Tsas-Orgilmaa;Kim, Sung-Tae;Han, Sang-Mook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.290-297
    • /
    • 2017
  • The flexural behavior tests of UHPC segmental U-girder and composite U-girder which has 160MPa compressive strength and 15.4m length were carried out. The test variables are volume fraction of steel fibers and slab over the U-girder. Each U-girder has longitudinal re-bars in web and lower flange. PS tendons which has 2 of 15.2mm diameter in upper flange and PS tendons which has 7 of 15.2mm diameter in lower flange were arranged and prestressed at onetime in U-girder connection stage. Enough strong prestressing force which applied to U-girder due to ultra high performance concrete strength can withstand the self weight and dead load in U-girder stage. By comparison with the brittle behavior of U-girder, composite U-girder showed the stable and ductile behavior. After the construction of slab over U-girder, flexural load capacity of composite U-girder can bear the design load in final construction stage with only one time prestressing operation which already carried out in U-girder stage. This simple prestressing method due to the ultra high strength concrete have the advantage in construction step and cost. The shear key which has narrow space has the strong composite connection between ultra high strength concrete U-girder and high strength concrete slab didn't show any slip and opening right before failure load.

Analysis of micro inorganic materials in linerboard mill (골판지 원지 제조 공정 내 미세 무기물질의 분석)

  • 윤혜정;류정용;김용환;신종호;송봉근
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.11a
    • /
    • pp.132-132
    • /
    • 2000
  • 환경오염과 이상기후의 영향으로 인한 수자원의 고갈과 함께 국내의 경우 수자원 개발 계획 및 수요량을 감안할 때 향후 7 년 내에 물부족 현상을 겪을 것이라는 보고가 있 었으며, 환경부담을 줄이기 위해 폐수의 배출기준은 강화되고 있다. 이러한 상황에서 제조 특성상 타 업종에 비해 폐수 발생량이 높은 편인 국내의 제지산업은 여러 해전부터 이에 대 한 방안을 모색하여 왔다. 일반적으로 폐수 수질 관리와 청수 사용량의 절감을 위해 고가의 폐수 처리 장치를 설치하거나 폐수 재활용을 통해 공정을 극도로 폐쇄화하는 방안으로 연구 가 진행되어 왔다. 이 중 용수의 재활용이 가장 경제적인 방법이지만, 재활용이 지속될수록 각종 무기염과 콜로이드성 유기물질이 축적되어 각종 약품의 효능 저하, 탈수속도의 저하 및 생산 제품의 품질 악화 등의 문제를 유발한다고 알려져 있다. 이를 해결하고자 하는 노 력으로 펄프 원료에 따른 공정수 내 용해성 물질의 분석과 재활용 횟수에 따른 각종 SS와 D DS의 축적 정도에 대한 기초 연구가 수행되었으며, 고폐쇄화된 공정에서 성능을 발휘할 수 있는 첨가제의 개발과 적용 방법에 대한 연구도 수행된 바 있다.여러 지종 가운데 골판지 원지는 용수의 재활용률이 상당히 높은 지종이기 때문에 공정수의 재활용이 진행될수록 열악한 저급 원료로부터 각종의 다양한 물질이 용출 혹은 배 출되며, 이러한‘물질은 골판지 원지의 강도 발현에 더욱 악영향을 미칠 것으로 판단되었다. 미세분으로 구성된 SS의 경우 이미 많은 연구를 통해 특성이 파악되었기 때문에 본 연구에 서는 ss를 제외한 공정수를 두 가지로 크게 나누어 고려하였다. 즉, ss로 측정되지 않지만 닥도를 유발할 수 있는 미세 무기물질과, 용해성의 무기염, 첨가제 및 추출물 둥으로 이루어 진 용해성 성분으로 나누어 분석하였으며, 또한 각각이 초지 특성에 미치는 영향을 살펴보 고자 하였다.을 해석코자 하였으며, 그 방법으 로 수치해석기법을 도입하였다. 또 실제 캘린더링 전후의 두께 변화를 측정하여 유리전이온도 의 도달 깊이와 비교하였다. 지필의 압축 정도는 롤의 직경과 닙 폭을 이용하여 MD 방향으 로 함수화하였으며, 열전달 계수로는 겉보기 값을 사용하였다. 이때 지펼은 균질한 것으로 가 정하였다. 함수율은 유리전이온도를 좌우하는 가장 큰 인자이나 본 연구에서는 항온항습처리 를 통해 유입지의 함수율을 고정시켰으며 캘린더링 시 함수율의 변이는 없다고 가정하였다. 그 결과 열침투깊이가 증가할수록 지필은 보다 변형되기 쉬운 상태가 되어 주어진 압력 조건에 대해 소성변형 정도가 증가하는 것으로 나타났다. 이는 캘린더링 전후에 두께 변화를 측정하여 정량적으로 평가할 수 있었다. 수치해석기법을 통해 같은 압력 조건에서 온도가 증 가함에 따라 혹은 같은 온도 조건에서 압력이 증가함에 따라 지필 내의 유리전이온도의 침투 깊이가 증가함을 알 수 있었으며 이는 캘린더링 전후의 두께 변화의 측정 결과와 일치하였 다. 또 NRT가 증가함에 따라서도 유리전이온도 침투 깊이가 증가하였다.합편에 비해 일부 우수한 양상을 보였지만 본 실험의 범위내에서는 통계적 정량적 차이를 제시할 수는 없었다. 향후 보다 광범위한 동물 실험이 필요할 것으로 사료된다.된다.하고도 완전교정술 도달 확률이 높은 치료전략이라는 사실을 입증하였으며 주대동맥폐동맥혈관부행지의 크기나 숫자가 단일화하기 쉬운 형태학적 특징을 지닌 경우에는 조기에 일단계완전교정술을 시행하여 양호한 결과를 얻을 수 있다는 사실을 발견하였다. 반면 본 환아군 중 단일화술을 먼저 시도한 군에서는 비록 단계적인 단일화를 시도한 군에서 단일화술과 관계된 수술사망율이 약간 낮기는 하였으나 완전교정술까지 완료될 가능성에는 차이가 없었다. 그러나 이 경우 보다 정련된 적응 환자의 선택을 통한 단일화 우선전략의 시도와 장기 추

  • PDF

Experimental analysis on the characteristics of enthalpy probe immersed in arc plasma flow (아크 플라즈마 유동에 삽입된 엔탈피 탐침의 동작특성 실험)

  • Seo, Jun-Ho;Nam, Jun-Seok;Choi, Seong-Man;Hong, Bong-Gun;Hong, Sang-Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1240-1246
    • /
    • 2010
  • Enthalpy probe with the inner and outer diameters of 1.5 mm and 4.8 mm, respectively, is designed and used to measure the temperatures and velocities along the centerline of Ar arc plasma flow until the probe was destroyed. For this purpose, Ar arc plasma flow is generated by non-transferred type DC arc heater with the power level of 17 kW. From this experiment, it is shown that the designed enthalpy probe can measure the temperature and velocity of arc plasma flow up to 12,000 K and 600 m/s, respectively, without destroy of probe tip. In this extreme case, the arc plasma flow is calculated to transfer the heat flux of ${\sim}5{\times}10^7\;W/m^2$ to the probe based on the heat and thermal boundary equations near the forward stagnation point of a body immersed in arc plasma flow. Consequently, the designed enthalpy probe can measure the wide ranges of plasma temperatures, velocities and concentrations simultaneously, which are generated by various types of arc heaters within the heat flux ranges of $0{\sim}5{\times}10^7\;W/m^2$ on the probe tip.

Structural Analysis and Design of B-pillar Reinforcement using Composite Materials (복합소재를 활용한 B필러 강화재의 구조해석 및 설계)

  • Kang, Ji Heon;Kim, Kun Woo;Jang, Jin Seok;Kim, Ji Wook;Yang, Min Seok;Gu, Yoon Sik;Ahn, Tae Min;Kwon, Sun Deok;Lee, Jae Wook
    • Composites Research
    • /
    • v.34 no.1
    • /
    • pp.35-46
    • /
    • 2021
  • This paper aims to reduce weight by replacing the reinforcements of the B-pillar used in vehicles with CFRP(Carbon Fiber Reinforced Plastics) and GFRP(Glass Fiber Reinforced Plastics) from the existing steel materials. For this, it is necessary to secure structural stability that can replace the existing B-pillar while reducing the weight. Existing B-pillar are composed of steel reinforcements of various shapes, including a steel outer. Among these steel reinforcements, two steel reinforcements are to be replaced with composite materials. Each steel reinforcement is manufactured separately and bonded to the B-pillar outer by welding. However, the composite reinforcements presented in this paper are manufactured at once through compression and injection processes using patch-type CFRP and rib-structured GFRP. CFRP is attached to the high-strength part of the B-pillar to resist side loads, and the GFRP ribs are designed to resist torsion and side loads through a topology optimization technique. Through structural analysis, the designed composite B-pillar was compared with the existing B-pillar, and the weight reduction ratio was calculated.