Browse > Article
http://dx.doi.org/10.15683/kosdi.2018.12.31.466

A Study on the Split Strength Characteristics of High Strength Concrete Sphere for Seismic Isolation  

Kim, Dong-Baek (Dep. of Civil, Safety & Environment Eng., Hankyong National University)
Kim, In-Bae (Dep. of Civil, Safety & Environment Eng., Hankyong National University)
Kim, Myung Gon (Dep. of Civil, Safety & Environment Eng., Hankyong National University)
Park, Bong-Gwan (Dep. of Civil, Safety & Environment Eng., Hankyong National University)
Publication Information
Journal of the Society of Disaster Information / v.14, no.4, 2018 , pp. 466-473 More about this Journal
Abstract
Purpose: Nowadays, it is the trend that seismic isolation method and combined method are used for seismic retrofitting, if concrete sphere foundation(CSF) system is applied to mid and low rise RC structure for the seismic isolation, the characteristics of concrete sphere, etc split tensile strength will be need. Method: The various experiments are carried out to know the split strength of high strength concrete sphere(60Mpa) and the ratio of split strength of concrete sphere to standard cylinder specimen, the size effect of concrete sphere with diameter. Results: It was purposed that the split strength of concrete sphere with diameter 150mm will be lower than that of cylinder specimen but, the average value is 4.39 Mpa and the ratio is higher than that of cylinder specimens, each 3.8% and 13.7%, the reason of this result is thought that the internal stress action of spot load and line load are different. Conclusion: There is a standard method for split tensile strength of cylinder type specimen, but there are few studies for the tensile split of concrete sphere. And therefore, in this study, theoretical and experimental details of concrete sphere will be served for the concrete sphere foundation or other sequent studies.
Keywords
Seismic isolation; Seismic performance; Mid and low rise-RC structure Concrete sphere - foundation (CSF); Split strength; Spot load; Line load;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 KS F 2403, "Moulding Method for Test Specimen of Concrete Strength", 2010
2 KS F 2405, "Testing Method for Compressive Strength of Concrete", 2010
3 KS F 2423, "Testing Method for Tensile Strength of Concrete", 2010
4 Y. G. Jin, "An Experimental Study on the Relationship between the Compressive Strength of High Strength Concrete and High Strength Concrete", Journal of Architectural Institute of Korea, Vol.2 No.2, pp. 129-134, 2002
5 D. B. Kim, Kim Myung Gon, Song Dae Geom , "An Experimental Study on the Size and Length Effect of High Strength Concrete Specimens", Journal of the Korean Society of Disaster Information, pp. 366-375, 2017
6 Yang Seo Gak, "Reinforced Concrete", pp. 366-375, 2014
7 Dong Myeong Sa, "Reinforced Concrete", pp. 147-149, 2018
8 Wu. B., Zhang, J. Williamns, and OU. J. " Hysteretic Behaviour of Improved Pall-typed Frictional Dampers", Engineering Structures 27, pp.1258-1267, 2005   DOI
9 Hyeong Seol Book Company, "Materials of Civil Engineering", pp. 451-458, 2015
10 Gu Mi Seo Gwan, "Materials of Civil Engineering", pp. 119-121, 2015