• Title/Summary/Keyword: 계량장치

Search Result 84, Processing Time 0.018 seconds

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF

Characteristics of Soil Erosion on the Forest Fired Sites by Using Rainfall Simulator (인공강우장치를 이용한 산불발생지의 토양침식 특성에 관한 연구)

  • Lee, Heon Ho;Joo, Jae Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.649-656
    • /
    • 2006
  • The purpose of study is to measure soil erosion quantity for elapsed four years from the fire on forest fired sites of Dong-gu, Daegu. This study was conducted to investigate the characteristics of soil erosion by fire occurrence influencing on the soil erosion were. Also analysis result follows that the relations between soil erosion quantity and rainfall intensity, the slope and elapsed year. The results analysed were as follows: 1. Soil erosion by year of occurrence of forest fire was increased 1.9 to 5.7 times as rainfall intensity was increased by 30 m/hr, and 1.4 to 14.2% as degree of slope was increased by $10^{\circ}$. 2. In the first year of forest fire occurrence, soil erosion was fairly heavy for 10 minutes of initial rainfall of which rainfall intensity was 80 m/hr and degree of slope was $30^{\circ}$. The amount of soil erosion was gradually reduced as elapsed time. From two years after fire, the amount of soil erosion by rainfall intensity and degree of slope was nearly constant. 3. The amount of soil erosion by rainfall intensity and slope in accordance with elapsed time after fire was reduced 28.9 to 94.1% in three years after occurrence of forest fire as compared to the first year of fire. Soil erosion was fairly heavy by rainfall intensity and slope in the first year of fire, but it was gradually reduced from two years after fire. 4. In the analysis on influences of each factors on the amount of soil erosion on forest fired sites, the amount of soil erosion was significant differences in major impacts of each rainfall intensity, degree of slope and elapsed year after fire and interaction of rainfall intensity${\times}$degree of slope and rainfall intensity${\times}$elapsed year after fire, but no differences were observed in interaction of degree of slope${\times}$elapsed year after fire and rainfall intensity${\times}$degree of slope${\times}$elapsed year after fire. Rainfall intensity was the most affecting factor on the amount of soil erosion and followed by degree of slope and elapsed year after fire. 5. For correlation between soil erosion and affecting three factors, soil erosion showed significant positive relation with rainfall intensity and degree of slope at I % level, and significant negative relation with elapsed year after fire at 1 % level. 6. As a result of regression of affecting three factors on soil erosion. rainfall intensity was most significant impact factor in explaining the amount of soil erosion on forest fired sites, followed by degree of slope and elapsed year after forest fire. 7. The formula for estimating soil erosion using rainfall intensity, degree of slope and elapsed year after forest fire occurrence was made. S.E = 0.092R.I + 0.211D.S - 0.942E.Y(S.E : Soil erosion, R.I : Rainfall intensity, D.S : Degree of slope, E.Y : Elapsed year after forest fire occurrence)

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.