• Title/Summary/Keyword: 게이트

Search Result 3,810, Processing Time 0.032 seconds

A 1.1V 12b 100MS/s 0.43㎟ ADC based on a low-voltage gain-boosting amplifier in a 45nm CMOS technology (45nm CMOS 공정기술에 최적화된 저전압용 이득-부스팅 증폭기 기반의 1.1V 12b 100MS/s 0.43㎟ ADC)

  • An, Tai-Ji;Park, Jun-Sang;Roh, Ji-Hyun;Lee, Mun-Kyo;Nah, Sun-Phil;Lee, Seung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.122-130
    • /
    • 2013
  • This work proposes a 12b 100MS/s 45nm CMOS four-step pipeline ADC for high-speed digital communication systems requiring high resolution, low power, and small size. The input SHA employs a gate-bootstrapping circuit to sample wide-band input signals with an accuracy of 12 bits or more. The input SHA and MDACs adopt two-stage op-amps with a gain-boosting technique to achieve the required DC gain and high signal swing range. In addition, cascode and Miller frequency-compensation techniques are selectively used for wide bandwidth and stable signal settling. The cascode current mirror minimizes current mismatch by channel length modulation and supply variation. The finger width of current mirrors and amplifiers is laid out in the same size to reduce device mismatch. The proposed supply- and temperature-insensitive current and voltage references are implemented on chip with optional off-chip reference voltages for various system applications. The prototype ADC in a 45nm CMOS demonstrates the measured DNL and INL within 0.88LSB and 1.46LSB, respectively. The ADC shows a maximum SNDR of 61.0dB and a maximum SFDR of 74.9dB at 100MS/s, respectively. The ADC with an active die area of $0.43mm^2$ consumes 29.8mW at 100MS/s and a 1.1V supply.

A Document Collection Method for More Accurate Search Engine (정확도 높은 검색 엔진을 위한 문서 수집 방법)

  • Ha, Eun-Yong;Gwon, Hui-Yong;Hwang, Ho-Yeong
    • The KIPS Transactions:PartA
    • /
    • v.10A no.5
    • /
    • pp.469-478
    • /
    • 2003
  • Internet information search engines using web robots visit servers conneted to the Internet periodically or non-periodically. They extract and classify data collected according to their own method and construct their database, which are the basis of web information search engines. There procedure are repeated very frequently on the Web. Many search engine sites operate this processing strategically to become popular interneet portal sites which provede users ways how to information on the web. Web search engine contacts to thousands of thousands web servers and maintains its existed databases and navigates to get data about newly connected web servers. But these jobs are decided and conducted by search engines. They run web robots to collect data from web servers without knowledge on the states of web servers. Each search engine issues lots of requests and receives responses from web servers. This is one cause to increase internet traffic on the web. If each web server notify web robots about summary on its public documents and then each web robot runs collecting operations using this summary to the corresponding documents on the web servers, the unnecessary internet traffic is eliminated and also the accuracy of data on search engines will become higher. And the processing overhead concerned with web related jobs on web servers and search engines will become lower. In this paper, a monitoring system on the web server is designed and implemented, which monitors states of documents on the web server and summarizes changes of modified documents and sends the summary information to web robots which want to get documents from the web server. And an efficient web robot on the web search engine is also designed and implemented, which uses the notified summary and gets corresponding documents from the web servers and extracts index and updates its databases.

A Study on Batch-Type Remote Plasma Dry Cleaning Process for Native Oxide Removal (배치식 플라즈마 세정 설비를 이용한 자연산화막 제거 공정)

  • Park, Jae-Young;Yi, Wook-Yeol;Hyung, Yong-Woo;Nam, Seok-Woo;Lee, Hyeon-Deok;Song, Chang-Lyong;Kang, Ho-Kyu;Roh, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.247-251
    • /
    • 2004
  • 반도체 소자의 제조에 있어 실리콘 표면에 성장한 자연산화막을 제거하기 위해 일반적으로 습식 세정 기술이 이용되어 왔다. 하지만 소자의 최소 선폭(design rule)이 nano급으로 고집적화 됨에 따라 contact hole 바닥의 자연산화막을 깨끗이 제거하는데 있어서 그 한계를 나타나고 있다. 이에 대한 효과적인 대안 공정으로 가스 건식 세정 기술이 연구되고 있다. 본 논문에서는 한 번에 50매 이상의 웨이퍼를 처리함으로써 생산성 측면에서 월등한 배치식 설비에서 원거리 플라즈마(remote plasma) 장치에서 2.450Hz의 마이크로웨이브(${\mu}$-wave)에 의해 형성시킨 수소라디칼과 $NF_3$ 가스를 이용하여 실리콘에 결함을 주지 않고 자연산화막을 선택적으로 제거하는 공정에 대해 고찰하였다. AFM을 이용한 표면분석, TEM을 이용한 물성분석, 그리고 ToF-SIMS 및 XPS를 이용한 화학 분석을 습식 및 건식 세정을 비교 평가한 결과, 건식 세정 공정이 실리콘 표면에 결함을 주지 않고 자연산화막을 제거 할 수 있음을 확인하였다. 산화막$(SiO_2)$, 질화막$(Si_3N_4)$, 그리고 다결정 실리콘(Poly-Si) 등의 각 막질별 식각 특성을 고찰하였으며, $NH_3$의 캐리어 가스인 $N_2$의 주입량을 조절함으로써 수소라디칼 형성 효율의 개선이 가능하였으며, 이로부터 게이트와 소스/드레인 사이를 절연하기 위해 이용되는 질화막의 식각 선택비를 2배 정도 개선할 수 있었다. nano급 소자에 실장하여 평가한 결과에서 불산(HF)에 의한 습식 세정 방식에 비하여 약 $20{\sim}50%$ 정도의 contact 저항 감소 효과가 있음이 확인되었다.두 소자 모두 $40mA/cm^2$ 에서 이상적인 화이트 발란스와 같은(0.33,0.33)의 색좌표를 보였다.epsilon}_0=1345$의 빼어난 압전 및 유전특성과 $330^{\circ}C$의 높은 $T_c$를 보였고 그 조성의 vibration velocity는 약4.5 m/s로 나타났다.한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다. 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만들기, 일반화가 가능한 문제 등으로 보고, 수학적 창의성 중 특히 확산적 사고에 초점을 맞추어 개방형 문제가 확

  • PDF

Suppression of misfit dislocations in heavily boron-doped silicon layers for micro-machining (마이크로 머시닝을 위한 고농도로 붕소가 도핑된 실리콘 층의 부정합 전위의 억제)

  • 이호준;김하수;한철희;김충기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.2
    • /
    • pp.96-113
    • /
    • 1996
  • It has been found that the misfit dislocations in heavily boron-doped layers originate from wafer edges. Moreover, the propagation of the misfit dislocation into a heavily boron-doped region can be suppressed by placing a surrounding undoped region. Using a surrounding undoped region the disloction-free heavily boron-deoped silicon membranes have been fabricated. The measured surface roughness, fracture strength, and residual tensile stress of the membrane are 20.angs. peak-to-peak, 1.39${\times}$10$^{10}$ and 2.7${\times}$10$^{9}$dyn/cm$^{2}$, while those of the conventional heavily boron-doped silicon membrane with high density of misfit dislocations are 500 peak-to-peak, 8.27${\times}$10$^{9}$ and 9.3${\times}$10$^{8}$dyn/cm$^{2}$ respectively. The differences between these two membranes are due to the misfit dislocations. Young's modulus has been extracted as 1.45${\times}$10$^{12}$dyn/cm$^{2}$ for both membranes. Also, the effective lattice constant of heavily boron-doped silicon, the in-plane lattice constant of the conventional membrane, and the density of misfit dislocation contained in the conventional membrane have been extracted as density of misfit dislocation contained in the conventional membrane have been extracted as density of misfit dislocation contained in the conventional membrane have been extracted as 5.424.angs. 5.426.angs. and 2.3${\times}$10$^{4}$/cm for the average boron concentration of 1.3${\times}$10$^{20}$/cm$^{-23}$ cm$^{3}$/atom. Without any buffer layers, a disloction-free lightly boron-doped epitaxial layer with good crsytalline quality has been directly grown on the dislocation-free heavily boron-doped silicon layer. X-ray diffraction analysis revealed that the epitaxial silicon has good crystallinity, similar to that grown on lightly doped silicon substrate. The leakage current of the n+/p gated diode fabricated in the epitaxial silicon has been measured to be 0.6nA/cm$^{2}$ at the reverse bias of 5V.

  • PDF

A 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS ADC Based on High-Accuracy Integrated Capacitors (높은 정확도를 가진 집적 커페시터 기반의 10비트 250MS/s $1.8mm^2$ 85mW 0.13un CMOS A/D 변환기)

  • Sa, Doo-Hwan;Choi, Hee-Cheol;Kim, Young-Lok;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.58-68
    • /
    • 2006
  • This work proposes a 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS A/D Converter (ADC) for high-performance integrated systems such as next-generation DTV and WLAN simultaneously requiring low voltage, low power, and small area at high speed. The proposed 3-stage pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The input SHA maintains 10b resolution with either gate-bootstrapped sampling switches or nominal CMOS sampling switches. The SHA and two MDACs based on a conventional 2-stage amplifier employ optimized trans-conductance ratios of two amplifier stages to achieve the required DC gain, bandwidth, and phase margin. The proposed signal insensitive 3-D fully symmetric capacitor layout reduces the device mismatch of two MDACs. The low-noise on-chip current and voltage references can choose optional off-chip voltage references. The prototype ADC is implemented in a 0.13um 1P8M CMOS process. The measured DNL and INL are within 0.24LSB and 0.35LSB while the ADC shows a maximum SNDR of 54dB and 48dB and a maximum SFDR of 67dB and 61dB at 200MS/s and 250MS/s, respectively. The ADC with an active die area of $1.8mm^2$ consumes 85mW at 250MS/s at a 1.2V supply.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

2DEG Transport Analysis in AlGaAs/GaAs Interface by MONTE-CARLO Method (MONTE-CARLO 방법에 의한 AlGaAs/GaAs 계면의 전자 전달특성 분석)

  • Nam, Seung-Hun;Jung, Hak-Ki;Kim, Bong-Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.94-101
    • /
    • 1989
  • Transport properties of 2DEG at AlGaAs/GaAs interface such as average electron energy, flight distance, each valley occupancy ratio, average electron velocity for various fields are investigated by MONTE-CARLO method. As the electric field increases, more electrons transit drastically from (000) valley to (000) upper valley. This phenomenon shows the nonstationary effect such as velocity overshoot. The duration of the transient decreases from about 1.4 psec for electric field E = 7KV/cm to about 0.7 psec for 12KV/cm. The average electron velocity during transient transport in 2DEG is about 8 times the steady-state velocity for E = 12KV/cm at room temperature. In comparison with bulk GaAs the peak velocity in the 2DEG is higher than that in even pure bulk GaAs at electric field E = 7 KV/cm. On the basis of the fact that the electrons in the 2DEG have larger peak velocity and shorter transient time of velocity than those in the bulk GaAs, it is suggested that the device with 2DEG may obtain higher mobility than that with bulk GaAs.

  • PDF

Difference of Time Course of Functional Recovery after Revascularization According to Preoperative Reversibility of Perfusion Impairment in Ischemic Myocardial Dysfunction (허혈성 심근 기능장애에서 술전 관류결손의 가역성에 따른 재관류 시술 이후 심근 기능회복 양상의 시간적 차이)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Kim, Ki-Bong;Kim, Yu-Kyeong;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.364-370
    • /
    • 2001
  • Purpose: In the revascuarization of ischemic dysfunctional myocardium, stunned myocardium was reported to recover function earlier than hibernating myocardium. It was also suggested that stunning and hibernation could be discriminated by reversibility of perfusion impairment on myocardial SPECT. In this study, we investigated the time course of functional recover after CABG according to reversibility of perfusion impairment. Materials and Methods: In 92 patients with coronary artery disease, Tl-201 rest/dipyridamole stress Tc-99m-MIBI gated SPECT was performed before, 3 months after, and 17 months after CABG. Using a 20-segment model, segmental perfusion and systolic thickening were automatically quantified. Perfusion-impaired segments with abnormal thickening were classified by reversibility into reversible (REV) and irreversible (IRREV) groups. The proportions of function-recovered segments were compared between groups and also between 3 months and 17 months in each group. Results: A total of 129 segments were Included In the analysis, and 76 were REV and 53 were IRREV. At 3 months after CABG, 61 segments (80%) in REV group showed functional recovery while 28 segments (53%) in IRREV group did (p<0.001). However, at 17 months after CABG, 60 segments (79%) in REV group and 37 segments (70%) un IRREV group showed functional recovery (p=n.s.). When comparing 3 months and 17 months in each group, REV group showed no difference, while IRREV group showed significant further improvement (p<0.05). Conclusion: In viable myocardium with ischemic myocardial dysfunction, the segments with reversible perfusion impairment recover function earlier after revascularization than irreversible segments.

  • PDF

Effects of Polyimide Passivation Layers and polyvinylalcohol Passivation Layers for Organic Thin-Film Transistors(OTFTs) (폴리이미드 패시베이션과 폴리비닐알콜 패시베이션 레이어 성막이 고성능 유기박막 트렌지스터에 주는 영향)

  • Park, Il-Houng;Hyung, Gun-Woo;Choi, Hak-Bum;Hwang, Sun-Wook;Kim, Young-Kwan
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.195-198
    • /
    • 2008
  • In this paper, it was demonstrated that organic thin-film transistors (OTFTs) were fabricated with the organic passivation layer by vapor deposition polymerization (VDP) processing. In order to form polymeric film as a passivation layer, VDP process was also introduced instead of spin-coating process, where polymeric film was co-deposited by high-vacuum thermal evaporation from 6FDA and ODA followed by curing. In order to investigate by compared with different passivation layer, the other OTFTs is fabricated to passivation by Polyvinylalcohol using spincoating. We can see that two different ways of passivation layer affect electric characteristic of OTFTs. The initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.24cm^2/Vs$, -3V, and $10^6$, respectively. Then after polyimide passivation layer, field effect mobility change from $0.24cm^2/Vs$ to $0.26cm^2/Vs$, threshold voltage from -3V to 1V and on-off current ratio from $10^6$ to $10^6$, respectively. In the case of polyvinylalcohol passivation, the initial electric characteristic of OTFTs before passivation such as field effect mobility, threshold voltage, and on-off current ratio are $0.13cm^2/Vs$, 0V, and $10^6$, respectively. Then after polyvinylalcohol passivation layer, field effect mobility changes from $0.13cm^2/Vs$ to $0.13cm^2/Vs$, threshold voltage from 0V to 2V, and on-off current ratio from $10^6$ to $10^5$, respectively.