• 제목/요약/키워드: 검출기 감도

Search Result 235, Processing Time 0.024 seconds

Analysis of Amperometric Response to Cholesterol according to Enzyme-Immobilization Methods (효소고정화 방법에 따른 콜레스테롤 검출용 바이오센서의 전류 감응도 분석)

  • Ji, Jung-Youn;Kim, Mee-Ra
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.5
    • /
    • pp.731-738
    • /
    • 2011
  • Cholesterol is the precursor of various steroid hormones, bile acid, and vitamin D with functions related to regulation of membrane permeability and fluidity. However, the presence of excess blood cholesterol may lead to arteriosclerosis and hypertension. Moreover, dietary cholesterol may affect blood cholesterol levels. Generally, cholesterol determination is performed by spectrophotometric or chromatographic methods, but these methods are very time consuming and costly, and require complicated pretreatment. Thus, the development of a rapid and simple analysis method for measuring cholesterol concentration in food is needed. Multi-walled carbon nanotube (MWCNT) was functionalized to MWCNT-$NH_2$ via MWCNT-COOH to have high sensitivity to $H_2O_2$. The fabricated MWCNT-$NH_2$ was attached to a glassy carbon electrode (GCE), after which Prussian blue (PB) was coated onto MWCNT-$NH_2$/GCE. MWCNT-$NH_2$/PB/GCE was used as a working electrode. An Ag/AgCl electrode and Pt wire were used as a reference electrode and counter electrode, respectively. The sensitivity of the modified working electrode was determined based on the amount of current according to the concentration of $H_2O_2$. The response increased with an increase of $H_2O_2$ concentration in the range of 0.5~500 ${\mu}M$ ($r^2$=0.96) with a detection limit of 0.1 ${\mu}M$. Cholesterol oxidase was immobilized to aminopropyl glass beads, CNBr-activated sepharose, Na-alginate, and toyopearl beads. The immobilized enzyme reactors with aminopropyl glass beads and CNBr-activated sepharose showed linearity in the range of 1~100 ${\mu}M$ cholesterol. Na-alginate and toyopearl beads showed linearity in the range of 5~50 and 1~50 ${\mu}M$ cholesterol, respectively. The detection limit of all immobilized enzyme reactors was 1 ${\mu}M$. These enzyme reactors showed high sensitivity; especially, the enzyme reactors with CNBr-activated sepharose and Na-alginate indicated high coupling efficiency and sensitivity. Therefore, both of the enzyme reactors are more suitable for a cholesterol biosensor system.

Design and Implementation of RF Module Part for Radar Detector (레이더 탐지기용 RF 모듈단 설계 및 구현)

  • Roh, Hee-Chang;Park, Wook-Ki;Jo, Yun-Hyun;Oh, Taeck-Keun;Park, Hyo-Dal
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.5A
    • /
    • pp.519-527
    • /
    • 2010
  • In this paper, we design and implement a broadband LNA(Low Noise Amplifier), a mixer, and oscillators in RF module part for radar detector. For resolving the limitation of the conventional product that the sensitivity is low due to the poor gain flatness, we propose the architecture of RF module part. The proposed RF module part is composed with a broadband 2-stage LNA, a mixer, and three oscillators, and improves the maximum gain and gain flatness for detecting various frequencies. The overall performances of RF module part are above 38 dB conversion gain in whole band and 1 dB gain flatness. These results show that the maximum gain which is the problem of the conventional product is improved 6 dB from 35 dB to 41 dB, and gain flatness is also improved 17 dB from 22 dB to 5 dB.

Concentration of Sodium Chloride Solutions Sensing by Using a Near-Field Microwave Microprobe (비접촉 근접장 마이크로파 현미경을 이용한 NaCl 용액의 농도 측정)

  • Kim, Song-Hui;Yoon, Young-Woon;Babajanyan, Arsen;Kim, Jong-Chul;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • We observed the NaCl concentration of solutions using a near-field microwave microprobe(NFMM). Instead of the usual technique, we take advantage of the noncontact evaluation capabilities of a NFMM. A NFMM with a high Q dielectric resonator allows observation of small variations of the permittivity due to changes in the NaCl concentration. The changes of NaCl concentration due to a change of permittivity of the NaCl solution were investigated by measuring the microwave reflection coefficient $S_{11}$ of the resonator. The NaCl sensor consisted of a dielectric resonator coupled to a probe tip at an operating frequency of about f=4 GHz. The change of the NaCl concentration is directly related to the change of the reflection coefficient due to a near field electromagnetic interaction between the probe tip and the NaCl solution. In order to determine the probe selectivity, we measured a mixture solution of NaCl and glucose.

Analysis of anatoxin-a in aqueous and cyanobacterial samples from korean lakes by liquid chromatography with fluorescence detection (액체크로마토그래피-형광검출법에 의한 호소시료의 아나톡신-a 분석)

  • Lee, In-Jung;Lee, Chul-Gu;Heo, Seong-Nam;Lee, Jae-Gwan
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.225-230
    • /
    • 2011
  • Anatoxin-a is a cyanobacterial neurotoxin with a high toxicity produced by Anabaena, Aphanizomenon and Oscillatoria. Water bloom, formed by Anabaena has been occurring frequently in Lake Yeongchun. It is need to develop a sensitive method for determination of anatoxin-a to control potential hazard in raw water resources. In this study, we developed a highly sensitive analytical method of anatoxin-a using solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection. Anatoxin-a was converted into a highly fluorescent derivative using 4-fuoro-7-nitro-2,1,3-benzoxadiazole (NBF-F). The method was evaluated in terms of linearity of calibration curve, recovery and repeatability, and the adequate values were obtained. The method detection limit was $0.034\;{\mu}g/g$ and $0.022\;{\mu}g/L$ for algal and water samples, respectively. The concentrations of anatoxin-a were measured in algal and water samples from Lake Andong, Yeongchun and Daechung and ranged from $0.135\;{\mu}g/g$ to $10.979\;{\mu}g/g$ in algal samples and not detected in water samples.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

천연물로부터의 다당류에 의한 항종양효과에 관한 연구 I. 형광기표지와 HPLC에 의한 당의 분석

  • 김영식;박호군
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.132-132
    • /
    • 1993
  • 정상세포의 암세포로의 전환에 수반하는 세포표면상에 당구조 변화가 주목을 받고 있으며 이에 탄수화물이 세포간의 상호작용, 성장 등에 중요한 역할을 하리라고 생각된다. 따라서, 당구조 변화를 야기 시키는 당분해소효소나 전이활성 효소의 활성이 주요한 임상적 지표가 될 수 있다. 또한 천연물에서 유래된 다당류 등이 면역증강 효과를 나타내면서 항종양 효과를 보여준다. 이와같은 일을 원활히 수행하기 위해서는 당을 분석하는 기술이 필요하다. 당을 분석하는 방법으로 많이 이용된 것 중의 하나가 유도체를 만들어 GC에 의해서 확인하는 것이고 또한 당은 chromophore가 없기 때문에 굴절율의 검출기를 이용한 HPLC에 의해서도 분석이 가능하다. HPLC에 의한 또 다른 방법으로 당의 환원당 말단에 형광기를 결합시켜 감도를 매우 높게하여 역상 칼람을 이용해 당을 분리할 수 있다. 환원당에 결합시킬 수 있는 물질로는 대부분 amine기를 띄고 있고 결합하여 형광을 나타내는 특징을 지니고 있다. 본 연구는 형광기를 결합시켜 전기영동과 HPLC에 의해 동시에 추적이 가능한 물질을 결합시켜서 분석을 용이하게 한 방법을 이용하여 단당류를 $C_{18}$ column에 의해서 분리하였고 또한 모델로서 면역증강제로 사용되는 운지버섯 및 영지버섯 다당류와 생약에서 분리한 지유의 당을 분석하였다. 현재까지의 결과로 가장 좋은 방법은 $C_{18}$-->phenyl column을 연결하여 isocratic 방법으로 분리하였을 때이었다. 버섯의 당은 대부분이 glucose로 이루어졌고 지유는 arabinose가 주 구성성분이었다. 위의 분석 기술을 이용하면 피코몰 범위내에서 정확한 구조를 가진 항암효과의 올리고당 및 암세포의 발현에 따른 당단백질의 당의 구조를 규명하는데 도움을 줄 수 있다.aeonol이 aspirin과 같거나 강한 사망 억제 효과가 있었다.cyclopropyl-7-(2-furanyl) -6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 4), 1-cyclopropyl-7-(2-thiophenyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 6) ,1-cyclopropyl-7-(3-pyridinyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 8), 1-cyclopropyl-7-(2-fluoro-3-pyridinyl)-6-fluoro-1,4-dihydro-4-oxo-3-quinoline carboxylic acid (compound 10)를 합성하였다.10^{-7}$ M)에 의한 단백인산화에 대하여는 더 미약한 억제-효과를 나타내었다. 이상의 결과는 PDE-1과 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경우 Dv값이 제일 작았다. 바. 본 연구의 목적중의 하나인

  • PDF

Compact Doppler Sensor Using Oscillator Type Active Antenna (능동 발진 안테나를 이용한 소형 도플러 센서)

  • Yun, Gi-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.49-56
    • /
    • 2011
  • In this paper, a compact doppler sensor with oscillator type active antenna operating at 2.4GHz frequency band is proposed to measure the distance or speed of a moving object. The active antenna has been realized by oscillator using radiator, patch antenna, as its resonator. The oscillation frequency is shifted depending on approaching of the object, and a detection circuit discriminates the frequency deviation. The oscillator type active antenna has been designed and simulated. The prototype fabricated has a very small circular disk type of diameter 30mm and height 4.2mm. As for antenna performance, broadside radiation pattern with beamwidth of $130^{\circ}$ and oscillation frequency of 2.373GHz has been measured. Test results as a doppler sensor shows that doppler signal voltage of about 190mV has been obtained for conducting plate moving 1 meter away from the sensor. And, doppler signal voltage has been linearly increased to the ground from 4.5m height by free-falling the sensor.

Detection of ClO4- via A Hypersensitive Receptor : Unusual Electrostatic Equilibria between Host and Guest in Aqueous Media (고감도 수용체에 의한 ClO4- 검출 : 수용액에서 주-객 이온간의 평형)

  • Lee, Young-A;Hong, Jongki;Jung, Ok-Sang
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.31-35
    • /
    • 2002
  • A useful receptor for the sensing of ${CIO_4}^-$ species with remarkable selectivity has been developed. The hypersensitive interaction between a host and a guest has been investigated for the complex $[Pd(Me_4en)(Py_2S){\cdot}2ClO_4]_4$ ($Me_4en$ = N,N,N',N'-tetramethylethylenediamine; $Py_2S$ = 4,4'-dipyridyl sulfide). The pyridyl moiety of $Py_2S$ exhibits two sets of $^1H$ resonances that are delicately dependent upon temperature, concentration, and media. The nonrigidity has been explained in terms of an electrostatic equilibrium between the tetrameric host and the ${CIO_4}^-$ guest. The equilibrium is a useful method for the detection of ${CIO_4}^-$ anion with remarkable selectivity via "a restricted guest within a big host" in aqueous solution.

Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating (열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계)

  • Kim, Jong Min;Lee, Seul-Gi;Kim, Hak Joon;Song, Sung Jin;Seok, Chang Seong;Lee, Yeong-Ze
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.202-210
    • /
    • 2016
  • A thermal barrier coating (TBC) has been widely applied to machine components working under high temperature as a thermal insulator owing to its critical financial and safety benefits to the industry. However, the nondestructive evaluation of TBC damage is not easy since sensing of the microscopic change that occurs on the TBC is required during an evaluation. We designed an eddy current probe for evaluating damage on a TBC based on the finite element method (FEM) and validated its performance through an experiment. An FEM analysis predicted the sensitivity of the probe, showing that impedance change increases as the TBC thermally degrades. In addition, the effect of the magnetic shield concentrating magnetic flux density was also observed. Finally, experimental validation showed good agreement with the simulation result.