• Title/Summary/Keyword: 검사 결과

Search Result 16,659, Processing Time 0.052 seconds

Inspections on the Food Safety of Pheasant and Mallard as a Meat Resource (식육자원(食肉資源)으로서의 꿩과 청둥오리 고기의 안전성(安全性) 검사(檢査))

  • Lee, Hun Jun;Oh, Hong Rock
    • Korean Journal of Agricultural Science
    • /
    • v.21 no.1
    • /
    • pp.28-36
    • /
    • 1994
  • Studies on the food-safety of pheasant and mallard, which belong to wild fowl as new meat resources. were carried out. The results were summarized as follows : 1. Food poisoning bacteria including Salmonella spp, was not detected from the inspections of small intestine, cecum, and rectum. 2. Parasite inspection tests on blood, feces, digestive organ, and thoracic organs were negative. 3. Antibiotic residues from the carcass muscle by simplified disk methods were not detected. 4. Seven different pesticide residue tests, such as DDT and BHT, on the muscle and liver were negative. 5. Four different kinds of toxic heavy metals such as Cd were much lower than the permissible concentration. Studies on the food safety tests and inspections from the pheasant and mallard were revealed that from taking this new food resources, the toxicities would be very low for the human health by the direct influences.

  • PDF

Prediction Performance of Naming Tests for Differentiating Mild Cognitive Impairment and Mild Dementia (경도인지장애와 경도 치매의 감별을 위한 대면 이름대기와 범주 이름대기의 예측 성능 비교)

  • Byeon, Haewon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.153-158
    • /
    • 2020
  • The present study identify the predictive power of confrontational naming and generative naming as screening tests for normal and early cognitive impairment. The subjects were analyzed for 203 healthy elderly, 106 mild cognitive impairment (MCI), 31 mild dementia. The confrontational naming was measured by the short-term Korean Boston Name Waiting Test, and the generative naming was measured by the Control Associative Word Test. As a result of polynomial logistic regression, both confrontational naming and generative naming had a significant effect on discriminating cognitive impairment (MCI, mild dementia) in general elderly (p<0.05). On the other hand, when distinguishing mild dementia from mild cognitive impairment, the generative naming-phonetic test had no significant odds ratio. The results of this study suggest that when discriminating mild dementia in mild cognitive impairment group, it is not meaningful to look only at the total score of generative naming test.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I) (전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I))

  • Kang, Young-June;Park, Nak-Kyu;Ryu, Won-Jae;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.393-401
    • /
    • 2002
  • Pipelines in power plants, nuclear facilities and chemical industries are often affected by corrosion effects. It is important to inspect the internal defects in pipelines in oder to guarantee safe operational condition. We have taken relatively much time, cost and manpower to use conventional NDT methods because these methods are contact measuring methods. In this paper, we used digital shearography, a laser-based optical method which allows full-field measurement of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time measurement. The experiment was performed with pressure vessels which has different internal cracks and detected internal cracks in the pressure vessels at a real time using phase shifting method.

Study on Performance Demonstration Test Result of Ultrasonic Examination in Nuclear Power Plant (원자력발전소 초음파검사자 기량검증시험 결과 검토)

  • Jung, Nam-Du;Moon, Yong-Sig;Lee, Seung-Pyo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.5
    • /
    • pp.384-389
    • /
    • 2014
  • In this paper, the result of an ultrasonic performance demonstration are analyzed. The requirements for an ultrasonic performance demonstration (PD) for a nuclear power plant were first described in ASME B&P Code Section XI, Appendix VIII (1989 winter addenda). In order to establish the performance demonstration scheme in Korean nuclear power plants, the Korea Hydro & Nuclear Power Co. Ltd (KHNP) has developed the Korean Performance Demonstration (KPD) system for the for the ultrasonic examination of nuclear power plants. An analysis of the ultrasonic performance demonstration results from 2004 through 2013 will improve the detection of flaws in an ultrasonic examination, as well as the further development of the KPD training system.

Navigation Learning Ability and Visuospatial Functioning of Mild Cognitive Impairment Patients in Virtual Environments (경도인지장애환자의 가상환경 내 길찾기 학습능력과 시공간 기능에 관한 연구)

  • Park, Su-Mi;Lee, Jang-Han
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.507-512
    • /
    • 2008
  • This study investigated the navigation ability of patients with MCI in Virtual Environments(VE) and on the visual functioning. The participants consisted of elderly adults with/without MCI. Neuropsychological tests(RCFT, BVRT, TMT, and Digit Span), the Groton Maze Learning Test(12trials), and the VE navigation learning task(6 trials) were performed. As a result, there were significant group differences for the RCFT and BVRT, but not for the GMLT. For the VE task, there was a significant difference between the MCI and normal group and no interactions between the groups and trials were found. The VE task was correlated with The RCFT, the BVRT, and the GMLT and omnibus the RCFT and the BVRT accounted for 45% of VE performances. Thus, we concluded that patients with MCI are inferior to VE navigation and visual retention/memory play a role in navigation abilities.

  • PDF

A Study on the Skirt Grading Rule According to Somatotype (스커트의 체형별 그레이딩룰에 대한 연구)

  • Jeong, Young-Mi;Koo, Mi-Ji
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.141-151
    • /
    • 1998
  • The purpose of this study was to suggest the skirt grading rule for different somatotypes. For this study 9 subjects were classified three types according to the shape of front hips such as diamond, standard, heart. Skirts pattern were made by Moonwha grading method for traditional grading rule. For each somatotypes, skirt pattern were graded by new grading rule. The sensory evaluations were practiced for appearance and function. At the result, comparing between the new grading rule and traditional grading rule, new grading rule was fitter than the traditional grading rule. And diamond type was distinctively better than the other somatotype at sensory evaluation appearance. For pattern making of diamond type it had better use the new grading rule that was considered the characteristics of body shape.

  • PDF

Performance of Artificial Intelligence and Elastography in Thyroid Nodule Diagnosis (갑상선 결절 진단에서 인공지능과 탄성초음파의 성능 분석)

  • Jee-Yeon Park;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.419-427
    • /
    • 2024
  • The objective of this study is to analyze and evaluate the diagnostic performance and utility of elastography and artificial intelligence program in distinguishing between benign and malignant thyroid nodule. In a hospital outpatient clinic, we performed thyroid ultrasound from January 2023 to June 2024, and retrospectively analyzed 126 patients who performed elastography, S-detect, and fine needle aspiration cytology(FNAC) because nodules were found. The analysis of differences based on cytology results showed statistically significant differences in age, nodule size, echogenicity, nodule orientation, margins, shape, presence of calcification, posterior shadowing, K-TIRADS ultrasound interpretation, S-detect results and elasticity contrast index. The ROC curve analysis determined a cut off value for the elasticity contrast index at 2.32, with diagnostic concordance rates of 0.66 for expert interpretation, 0.49 for S-detect, and 0.67 for the elasticity contrast index, indicating superior diagnostic performance with elastography. Thus, elastography may ge used as an adjunct tool to minimize unnecessary repeat examinations and the frequency of tissue biopsies in the diagnosis of thyroid nodules.

Analysis of K-ABC Profile of Young Gifted Children and Ordinary Young Children (유아영재와 일반유아의 K-ABC 프로파일 분석)

  • Oh, Mee-Hyeong
    • Journal of Gifted/Talented Education
    • /
    • v.19 no.2
    • /
    • pp.241-260
    • /
    • 2009
  • The purpose of this study was to contrast young gifted children with ordinary young children in K-ABC profile. The subject were 51 young gifted children and 51 ordinary young children, 2 to 4 years of age. Data of children's K-ABC profile were analyzed by Correlation and Crosstabs. The main results of this study were as follows: First, in the case of ordinary young children, there were significant positive correlation among 'Mental Processing Composite' and all sub-tests of mental processing composite except 'face memory' test, 'Achievement Scale'. In young gifted children, there were significant positive correlation among 'Mental Processing Composite' and just four sub-tests of mental processing composite, and there were no significant correlation between 'Mental Processing Composite' and 'Achievement Scale'. Second, there were no significant differences among all sub-tests' strength and weakness in young gifted children and ordinary young children. Third, young gifted children got higher score in 'Sequential Processing Scale' and 'Mental Processing Composite' than 'Achievement Scale'. But in ordinary young children, there were no significant differences among all K-ABC' sub-scales.

The Effect of in vitro Hemolysis on Vitamin $B_{12}$ / Folic Acid Results (용혈이 Vitamin $B_{12}$ / Folic acid 검사 결과에 미치는 영향)

  • Kim, Mi-Sook;Cho, Youn-Kyo;Im, Do-Hw;Seo, So-Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.62-65
    • /
    • 2008
  • Purpose: Vitamin $B_{12}$ and folic acid are type of water-soluble vitamin and those work as a secondary vital enzyme, but especially those are involved in the nuclear DNA synthesis. Those are mainly measured in order to diagnose megaloblastic anemia and to assess the storage of folic acid during pregnancy. It is generally known that the hemolyzed serum is useless for folic acid and vitamin $B_{12}$, but it is not easy to abide by this information because our lab (Samkwang Medical Laboratories) is reference laboratory. We tested how much the extent of hemolyzed serum had influence on the results. Materials and Method: We performed the tests of vitamin $B_{12}$, folic acid. For the hemolysis effect study, we used 40 cases. According to the level of A, B and C groups, each group had 10 samples which were mechanically hemolyzed serum. Results: Hemolysis did not affect the vitamin $B_{12}$ results. However in case of folic acid, the value increased according to the degree of hemolysis. And severe hemolyzed cases had the highest value (greater than 20 ng/ml). Conclusions: Preventing the hemolysis, it has to be informed that blood-collecting, separation and storage are performed more carefully. As you see from the above results, hemolyzed serum is not proper for folic acid test, and hemolysis does not affect the results of vitamin $B_{12}$. However, for the more accurate results, it is necessary to avoid hemolysis.

  • PDF