• Title/Summary/Keyword: 검교정

Search Result 113, Processing Time 0.03 seconds

The Neonatal Follow up and Correlative Analysis of Fetal Hydronephrosis (산전 수신증의 생후 추적 관찰)

  • Yoon Ho-Young;Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil;Kim Myung-Joon
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Purpose: To determine the various prenatal factors related to the prenatal hydronephrosis diagnosed on prenatal ultrasonography. We also attempted to correlate the prenatal and neonatal renal pelvic anteroposterior diameter with the outcome in infancy Methods: Between 1985 and 1997. We retrospectively reviewed 105 renal unit (75 patient) with fetal hydronphrosis persisting postnatally. Investigation consisted of renal ultrasonography, voiding cystourethrography, diurectic renogram, and DMSA scan. Results: The 75 patient assesed had the following underlying cause: UPJ(Ureteropelvic juction) obstruction(52%). multicystic dysplastic kidney(10%). UVJ (Ureterovesicai juction) obstruction (10%) and no underlying cause (25%). Of theses cases 36 cases (40 renal unit) underwent operation, while 28 cases (50 renal unit) resoled spontaneously. 12% of mild hydornephrosis deteriorated. whereas 50% of modrate hydrophrosis and 81% of severe hydronephrosis required surgical correction. Attempting to find the renal unit that were at risk for deterioration. our study showed that urinary tract infection group and calyceal blunting group had a predictive role. Conclusion: It is necessary to follow up after birth dilatation of caylx or urinary tract infection are present. Early operation is considered when prenatal pelvic AP diameter greater is than 22 mm and postnatal diameter greater than 17 mm. This may make it possible to prevent further progression of renal damage and prompt treatment of asymptomatic hydronephrosis before complications occur.

  • PDF

The Study on Improvement of Reading Ability for Dyslexia Wearing Color filter lens (ChromaGenTM Lens) (칼라필터 렌즈(ChromaGenTM)를 이용한 읽기능력 향상에 대한 임상연구)

  • Lee, Seok-Ju;Park, Ji-Hoon;Lee, So-Hee;Whang, Kwang-Ha;Ryu, Guen-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 2011
  • Purpose: In this study we investigated improvement degree of reading ability of the student who was in a condition of dyslexia symptoms by wearing $ChromaGen^{TM}$ lenses. Methods: After wearing the $ChromaGen^{TM}$ lens for 3 months, the dyslexia symptoms corrective lens, 52 students who had suspected symptom of dyslexia were asked questions, and we measured the improvement degree of reading ability of the student. Results: The $ChromaGen^{TM}$ wearer read 110.26${\pm}$22.07 words in 1 minute, and naked yeses or glass wearing students read 106.42${\pm}$22.70 words. Reading ability of the student having suspected symptom of dyslexia were measured after wearing $ChromaGen^{TM}$ for 3 months. The results showed improvement reading ability of 3.70${\pm}$0.29 (p=0.01, t=2.26), 4.50%${\pm}$0.10 (p=0.01, t=2.78) for $ChromaGen^{TM}$ wearer with statistical difference. A survey on the satisfaction of reading improvement with wearing $ChromaGen^{TM}$ showed that 88.4% of questioned person answered wearing $ChromaGen^{TM}$ had improved their dyslexia symptoms. Conclusions: With statisical significance (p<0.05). this study suggests that $ChromaGen^{TM}$ lens has an effect on improving reading speed of dyslexia patient. We know from these results that the $ChromaGen^{TM}$ lens which is used to dyslexia had an effect to improvement of reading speed for dyslexia. And the results of this study is statistically different (p<0.05).

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

A Study on the Changes of Accommodative Function in Respect to the Viewing Angle (주시각도에 따른 조절기능의 변화)

  • Lee, Hark-Jun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the relationship between the accommodative facility, blink rate and accommodative lag according to the change of angles of main viewpoint of near distance worker and study an appropriate viewing angle that mitigates asthenopia, such as headaches or eye fatigue accompanied when reading and staring at the computer or TV for a long time. Methods: Total of 27 people including 12 male university students and 15 female university students in the age of 20 to 36 with frequent near distance works, such as computers, were selected to study the accommodative facility, the blink rate and the accommodative lag in accordance with the change of viewing angles of the near distance workers. The refraction error was corrected completely and the phoropter was shifted to near distance mode to locate the near distance indication at 40 cm. The accommodative facility and the blink rate were measured for one minute at each viewing direction of $40^{\circ}$ downward, $20^{\circ}$ downward, horizontal, and $20^{\circ}$ upward directions based on the horizontal line and the accommodative lag was measured in dynamic retinoscopy using retinoscope. Results: As a result, when the main viewpoint was moved on upper direction from the $40^{\circ}$ below, the accommodative facility was reduced and the blink rate and the accommodative lag were increased so their eyes became dry and the accommodation response was reduced. Conclusions: In near distance works, the eye fatigue level can be minimized by locating a book or a computer screen $40^{\circ}$ below than the horizontal direction.

  • PDF

A Study on Ocean Meteorological Observation Wave Meter System based on Kalman-Filter (칼만 필터 기반의 스마트 해양기상관측 파고 시스템 연구)

  • Park, Sanghyun;Park, Yongpal;Kim, Heejin;Kim, Jinsul;Park, Jongsu
    • Journal of Digital Contents Society
    • /
    • v.18 no.7
    • /
    • pp.1377-1386
    • /
    • 2017
  • We propose a smart ocean meteorological observation system which is capable of real-time measurement of vulnerable marine climate and oceanographic conditions. Besides, imported products have several disadvantages such that they can't be measured for a long time and can't transmit data in real time. In the proposed system, smart ocean observation digging system, it observes real-time ocean weather with data logger methods. Furthermore, we also use existing dataloggers functions with various sensors which are available in the ocean at the same time. Also, we applied the Kalman-filter algorithm to the ocean crest measurement to reduce the noise and increase the accuracy of the real-time wave height measurement. In the experiment, we experimented the proposed system with our proposed algorithms through calibration devices in the real ocean environment. Then we compared the proposed system with and without the algorithms. As a result, the system developed with a lithium iron phosphate battery that can be charged by a system used in the ocean and minimized power consumption by using an RTC based timer for optimal use. Besides, we obtained optimal battery usage and measured values through experiments based on the measurement cycle.

Flight model development of the NISS structure for NEXTSat-1 payload

  • Moon, Bongkon;Ko, Kyeongyeon;Lee, Duk-Hang;Jeong, Woong-seob;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Kim, Mingyu;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.87.3-88
    • /
    • 2017
  • 한국천문연구원은 차세대소형위성 1호의 근적외선 영상분광기 NISS (Near-infrared Imaging Spectrometer for Star formation history) 탑재체를 개발하여 2017년 6월 30일에 최종 비행모델을 납품하였고, 이 발표는 탑재체 NISS 구조체의 비행모델 개발 결과를 보고한다. NISS는 0.9 - 2.5um (R~20) 근적외선 파장에서 관측을 해야 하기 때문에, 구조체의 배경잡음을 없애기 위해서 200K까지 passive cooling으로 냉각되며, H2RG 검출기는 소형 냉동기에 의해 약 88K에서 운영된다. NISS 구조체의 passive cooling을 효율적으로 수행하기 위해서 방열판, Kevlar 지지대, MLI, 표면제어용 필름 등을 조립하였고, 실제 지상 시험을 통해서 그 성능을 확인하였다. NISS 구조체는 최종 시스템 조립 과정에서 전자부 하네스 조립을 함께 수행했으며, 온도 모니터링 센서를 부착하고 소형 냉동기 피드백 온도를 반복 시험을 통해서 결정하였다. NISS 구조체는 미러 및 렌즈를 지지하는 광기계부를 함께 포함하기 때문에 발사 및 우주환경에서 광학 성능을 유지하기 위한 설계를 거쳐서 제작 되었으며, 최종 시스템 검교정 시험, 진동 및 열진공 시험을 통해서 그 성능을 확인하였다. NISS를 탑재한 차세대소형위성 1호는 2018년 상반기에 미국의 Falcon 9 발사체에 실려서 발사될 예정이다.

  • PDF

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

The Effect of cycloplegia in Emmetropia with Use of Cycloplegia (조절마비제로 정시안이 된 눈의 조절마비 효과)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Jang, Seong-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.201-206
    • /
    • 2006
  • The purpose of this study is observed effect of cycloplegia in emmetropia with use of cycloplegia. We examined the naked visual acuity, mainfest refraction, 105eyes with emmetropia(under SE ${\pm}0.50D$, Cyl ${\pm}1.00D$) after the use of cycloplegia. We used Nidek ARK-700 autorefractometer. Sexual difference of mainfest refraction error showed in male -0.67D, female -0.92D and difference of the CR and the MR male 0.5D, female 0.81D the total mean 0.69D. The naked visual acuity were in male 0.82, female 0.74, total mean 0.77. Age comparison, difference CR and MR were total mean 0.69D and 13 years group 1.1D were the highest. The naked visual acuity were in the highest 10 years group 0.86. Effect of cycloplegia was $0.69D{\pm}0.79$ in emmetropia and visual acuity was $0.77{\pm}0.21$. The optician, it will not be able to use cycloplegia, must pay attention spectacle prescription unnecessary and over correction in condition below -0.75D MR, above 0.77 visual acuity.

  • PDF

The effect of indomethacin on the matrix metalloproteinases in canine permanent tooth eruption (인도메타신의 투여가 치아 맹출 시 기질금속단백분해 효소의 분포에 미치는 영향)

  • Kang, Yoon-Goo;Nam, Jong-Hyun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.91-102
    • /
    • 2006
  • Tooth eruption requires remodeling of surrounding tissues. This study was aimed to investigate the effect of indomethacin on the dental follicle and paradental tissues during tooth eruption by observing the distribution and expression of MMP by the immunohistochemical method. Ten mongrel dogs of ten to twelve weeks old were divided into 5 groups; four experimental groups administered indomethacin 2 mg/Kg/day and 8 mg/Kg/day orally 2 times a day for 14 days and 7 days respectively, and the control group was administered a placebo. Permanent teeth before eruption and their surrounding tissues were selected and excised. H&E staining and immunohistochemical stainings of MMP-3 and -9 were performed and examined under the light microscope. Osteoclasts, osteoblasts, periodontal ligament cells, ameloblasts and odontoblasts of the control group all expressed MMP-3 and -9. In the experimental group, osteoclasts, osteoblasts and periodontal ligament cells showed reduced expression of MMP-3 and -9. Magnitude of MMP reduction In the experimental group showed a time and dose of indomethacin administration dependent manner. These results show that indomethacin inhibited MMP-3 and -9 expression in the dental follicle and surrounding tissues and suggest that when indomethacin is administered for long periods, tooth eruption could be delayed.

Biventricular Repair of Critically III Neonate with Ebstein′s Anomaly - Report of 1 case - (증상이 심한 신생아 Ebstein 기형의 양심실성교정 -1례 보고-)

  • Kong, Joon-Hyuk;Kim, Woong-Han;Ryu, Jae-Wook;Lee, Seog-Ki;Baek, Man-Jong;Lim, Cheong;Kim, Soo-Cheol;Oh, Sam-Se;Na, Chan-Young;Kim, Soo-Jin;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.303-306
    • /
    • 2002
  • Patients with severe Ebstein's anomaly showing in the neonatal period, represent progressive cardiac enlargement with pulmonary hypoplasia and functional pulmonary atresia with patent ductus alteriosus-dependent pulmonary circulation. Biventricular repair in these patients had been mostly unsuccessful except for Starnes' procedure that converts the anatomy to single ventricle physiology for Fontan procedure. A 4-days old male was admitted with the diagnosis of severe Ebstein's anomaly with anatomic pulmonary atresia and severe cardiac enlargement. He successfully underwent biventricular repair with vertical plication method of atrialized right ventricle, tricupid annuloplasty, transannular right ventricular outflow tract reconstrulltion, atrial septal defect patch closure with fenestration, and right atrial reduction angioplasty Postoperatively, cardiothoracic ratio was significantly reduced and mild tricuspid regurgitation was remnant in echocardiography. The patient is currently 10 months old and is fully active without restrictions.